High spectral resolution infrared sounders are an integral component of the global observing system and are used in a broad range of applications. This is enabled by their high accuracies which are ensured by rigorous calibration/validation activities. One of these activities is the post‐launch intercomparison with other high spectral resolution infrared sounders using simultaneous nadir overpasses (SNOs). This paper introduces a novel application of the previously developed SNO methodology by including time difference histogram symmetrization and a spatial sampling uncertainty. Where possible, radiometric measurement uncertainties are included and propagated through the statistics. Comparisons of Atmospheric Infrared Sounder (AIRS), METOP‐A/B/C Infrared Atmospheric Sounding Interferometer (IASI), and Cross‐track Infrared Sounder (CrIS) from 1 October 2019, to 1 October 2020, are analyzed. Results show AIRS and IASI differences as well as CrIS and AIRS differences are generally less than 0.4 K across the spectrum, and CrIS and IASI differences are generally less than 0.25 K. Comparison of the Suomi National Polar‐Orbiting Partnership and NOAA‐20 CrIS instruments via IASI and AIRS shows differences are generally less than 0.1 K across all bands and that the two CrIS instruments statistically agree within their radiometric uncertainties except for the narrow 2,370 cm−1 region where artifacts due to brightness temperature conversion are prone to occur.
7 August 2017 in Journal of Geophysical Research: Atmospheres
The U.S. National Oceanic and Atmospheric Administration (NOAA) recently began operational processing to derive vertical temperature profiles from two new sensors, Cross‐Track Infrared Sounder and Advanced Technology Microwave Sounder, which were developed for the next generation of U.S. weather satellites. The NOAA‐Unique Combined Atmospheric Processing System (NUCAPS) has been developed by NOAA to routinely process data from future Joint Polar Satellite System operational satellites and the preparatory Suomi‐NPP satellite. This paper assesses the NUCAPS vertical temperature profile product from the upper troposphere into the middle stratosphere using radiosonde and GPS radio occultation (RO) data. Radiosonde data from the Department of Energy Atmospheric Radiation Measurement (ARM) program are=] compared to both the NUCAPS and GPS RO temperature products to evaluate bias and RMS errors. At all three fixed ARM sites for time periods investigated the NUCAPS temperature in the 100–40 hPa range is found to have an average bias to the radiosondes of less than 0.45 K and an RMS error of less than 1 K when temperature averaging kernels are applied. At a 95% confidence level, the radiosondes and RO were found to agree within 0.4 K at the North Slope of Alaska site and within 0.83 K at Southern Great Plains and Tropical Western Pacific. The GPS RO‐derived dry temperatures, obtained from the University Corporation for Atmospheric Research Constellation Observing System for Meteorology, Ionosphere, and Climate (COSMIC) mission, are used as a common reference for the intercomparison of NUCAPS temperature products to similar products produced by NASA from Atmospheric Infrared Sounder (AIRS) and by European Organisation for the Exploitation of Meteorological Satellites from MetOp‐B Infrared Atmospheric Sounding Interferometer (IASI). For seasonal and zonal scales, the NUCAPS agreement with AIRS and IASI is less than 0.5 K after application of averaging kernels.
We assess and illustrate the benefits of high-altitude attainment of balloon-borne radiosonde soundings, up to and beyond 10 hPa level compared to, for example, 30 hPa, at operational stations and at sites of the Global Climate Observing System (GCOS) Reference Upper Air Network (GRUAN). We first discuss technical challenges and the possible solutions for balloon soundings at these higher altitudes. Then, we assess the role of high-ascent radiosonde measurements in climate monitoring and various process studies, contributions to satellite calibration and validation, and impacts on numerical weather prediction systems. The analysis herein shows that the extra costs and technical challenges involved in consistent attainment of high ascents are more than outweighed by the benefits for a broad variety of real-time and delayed-mode applications. Consistent attainment of high ascents should therefore be pursued across the GRUAN network and the broader observational network.
9 June 2021 in IEEE Transactions on Geoscience and Remote Sensing
The Cross-track Infrared Sounder (CrIS) is a Michelson-type Fourier Transform Spectrometer. The CrIS flight module 2 instrument was launched into orbit on November 18, 2017, onboard the NOAA-20 satellite as part of the United States (US) Joint Polar Satellite System (JPSS). The CrIS instrument measures the top-of-atmosphere upwelling spectral radiance in the thermal infrared (IR) spectrum. These measurements provide critical information for medium-range weather forecasting, and the retrieval of atmospheric profiles of temperature, water vapor, and other trace gases. The instrument noise equivalent radiance differential (NEdN) estimates are used by the weather forecasting systems, the trace gas atmospheric retrieval algorithms, and for trending the health and stability of the instrument over time. The current operational NEdN estimate is calculated using instrument observations from the deep space (DS) view and the internal calibration target (ICT). Two alternative methodologies are described here based on the principal component analysis (PCA) of an ensemble of calibrated Earth scene (ES) spectra. The NEdN calculation methods show that the instrument meets the specifications with a margin for all 27 detectors with an exception of one midwave IR (MWIR) field-of-view (FOV) 9, which is borderline. The PCA analysis shows that warmer ES spectra have higher noise, known as scene shot, for the short-wave IR (SWIR) band. Using the PCA analysis, the NEdN for the long-wave IR FOV 5 is 30% higher than the NEdN calculated by the operational algorithm. Correlated noise is also found due to the effect of the instrument self-apodization correction.
This paper provides a procedure for the simulation of radiances from the U. S. National Oceanic and Atmospheric Administration (NOAA) Cross-track Infrared Sounder (CrIS) Fourier Transform Spectrometer to include spectral ringing effects caused by the finite-band, non-flat instrument spectral response to incident radiation. A simulation using a line-by-line radiative transfer model is performed to illustrate the magnitude of the effect and to indicate which spectral channels are likely to be impacted. Comparisons with CrIS observations are made to show that for most channels this effect is negligibly small compared to errors in the radiative transfer calculations but for the longwave edge of the CrIS longwave band and a few other regions, the brightness temperature ringing is significant. While the ringing artifact described in this paper may appear to be removed when Hamming apodization is applied, as is done for the assimilation of CrIS data into Numerical Weather Prediction (NWP) models, it is still present, and its influence reappears if the spectral correlation induced by apodization is properly handled to preserve the information content that derives from high spectral resolution. Inclusion of the instrument responsivity in calculated spectra to properly mimic the observed spectra as defined here eliminates artifacts from this type of ringing. Users of CrIS radiances should consider whether this effect is important for their application.