Sadaf Sarafan

Ms. Sadaf Sarafan

University of California, Irvine, Irvine, California, USA
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2020 in Technologies
Verified
Journal Article
Open access
PDF file
Sadaf SarafanSadaf Sarafan
Sadaf Sarafan
TLTai Le
Tai Le
ANAmir mohammad Naderi
Amir mohammad Naderi
QNQuoc Dinh Nguyen
Quoc Dinh Nguyen
BKBrandon Tiang-Yu Kuo
Brandon Tiang-Yu Kuo
Hung CaoHung Cao
Hung Cao
Monitoring of fetal electrocardiogram (fECG) would provide useful information about fetal wellbeing as well as any abnormal development during pregnancy. Recent advances in flexible electronics and wearable technologies have enabled compact devices to acquire personal physiological signals in the home setting, including those of expectant mothers. However, the high noise level in the daily life renders long-entrenched challenges to extract fECG from the combined fetal/maternal ECG signal recorded in the abdominal area of the mother. Thus, an efficient fECG extraction scheme is a dire need. In this work, we intensively explored various extraction algorithms, including template subtraction (TS), independent component analysis (ICA), and extended Kalman filter (EKF) using the data from the PhysioNet 2013 Challenge. Furthermore, the modified data with Gaussian and motion noise added, mimicking a practical scenario, were utilized to examine the performance of algorithms. Finally, we combined different algorithms together, yielding promising results, with the best performance in the F1 score of 92.61% achieved by an algorithm combining ICA and TS. With the data modified by adding different types of noise, the combination of ICA–TS–ICA showed the highest F1 score of 85.4%. It should be noted that these combined approaches required higher computational complexity, including execution time and allocated memory compared with other methods. Owing to comprehensive examination through various evaluation metrics in different extraction algorithms, this study provides insights into the implementation and operation of state-of-the-art fetal and maternal monitoring systems in the era of mobile health.

5 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Sadaf SarafanSadaf Sarafan
Sadaf Sarafan
TLTai Le
Tai Le
MLMichael P. H. Lau
Michael P. H. Lau
AHAfshan Hameed
Afshan Hameed
TGTadesse Ghirmai
Tadesse Ghirmai
Hung CaoHung Cao
Hung Cao
Fetal electrocardiogram (fECG) assessment is essential throughout pregnancy to monitor the wellbeing and development of the fetus, and to possibly diagnose potential congenital heart defects. Due to the high noise incorporated in the abdominal ECG (aECG) signals, the extraction of fECG has been challenging. And it is even a lot more difficult for fECG extraction if only one channel of aECG is provided, i.e., in a compact patch device. In this paper, we propose a novel algorithm based on the Ensemble Kalman filter (EnKF) for non-invasive fECG extraction from a single-channel aECG signal. To assess the performance of the proposed algorithm, we used our own clinical data, obtained from a pilot study with 10 subjects each of 20 min recording, and data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations. The proposed methodology shows the average positive predictive value (PPV) of 97.59%, sensitivity (SE) of 96.91%, and F1-score of 97.25% from the PhysioNet 2013 Challenge bank. Our results also indicate that the proposed algorithm is reliable and effective, and it outperforms the recently proposed extended Kalman filter (EKF) based algorithm.

4 August 2022 in Technologies
Verified
Journal Article
Open access
PDF file
KSKaveh Shahverdi
Kaveh Shahverdi
SHSoheil Hashemi
Soheil Hashemi
Sadaf SarafanSadaf Sarafan
Sadaf Sarafan
Hung CaoHung Cao
Hung Cao
Our objective is to design triple-band implantable antennas with wide bandwidths and appropriate sizes for biomedical applications. The targeted design frequencies are 400 MHz, 2.4 GHz, and the new Wi-Fi band of 5.7 GHz. Three triple-band antennas with bandwidth improvements are presented to insure all-time data connection. The proposed triple-band implantable antennas benefit from combining long-distance data transfer at lower frequency bands and a higher effective bandwidth, and high-speed communications at higher frequency bands, which will have flexibility for a variety of applications. A comprehensive explanation of the design procedure to achieve multiple-band implantable antennas is provided. Furthermore, miniaturization techniques are utilized to design antennas in compact sizes suitable for biomedical applications. In this paper, three-layer structures including skin, fat, and muscle are used for the designs, then antennas are placed in the chest, neck, head, and hand of different human voxels to compare antennas’ performance. Additionally, normal and overweight human effects on antenna performance were compared. Antennas have 2 to 6 dBi directivity for telemetry usage, and they are designed to satisfy the absorption limit for the human body to keep the Specific Absorption Rate (SAR) averaged over 1 g of tissue less than 1.6 W/kg and over 10 g of tissue less than 2 W/kg, according to IEEE standard. The antennas include fractal, meandered, and comb types with sizes of 1.4 mm × 10 mm × 10 mm, 3.04 mm × 10 mm × 17.25 mm, and 1.4 mm × 12 mm × 12 mm, respectively. The designed antenna showed an impedance bandwidth of 53 MHz to 120 MHz, 90 MHz to 320 MHz, and 300 MHz to 1200 MHz at the three bands. The meandered antenna was selected for validation of simulations, and its S parameters were measured in the equivalent liquid phantom of body tissues.

13 October 2022 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
NMNastaran Mansourian
Nastaran Mansourian
Sadaf SarafanSadaf Sarafan
Sadaf Sarafan
FAFarah Torkamani Azar
Farah Torkamani Azar
TGTadesse Ghirmai
Tadesse Ghirmai
Hung CaoHung Cao
Hung Cao

1 November 2021 in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Verified
Conference Paper
Closed access
Sadaf SarafanSadaf Sarafan
Sadaf Sarafan
TLTai Le
Tai Le
FEFloranne Ellington
Floranne Ellington
ZZZhijie Zhang
Zhijie Zhang
MLMichael P. H. Lau
Michael P. H. Lau
HCHung Cao
Hung Cao
We develop a novel wearable fetal electrocardiogram (fECG) monitoring system consisting of an abdominal patch that communicates with a smart device. The system has two main components: the fetal patch and the monitoring app. The fetal patch has electronics and recording electrodes fabricated on a hybrid flexible-rigid platform while the Android app is developed for a wide range of applications. The patch collects the abdominal ECG (aECG) signals that are sent to the smart device app via secure Bluetooth Low Energy (BLE) communication. The app software connects to a cloud server where processing and extraction algorithms are executed for real-time fECG extraction and fetal heartrate (fHR) calculation from the collected raw data. We have validated the algorithms and real-time data recordings on pregnant subjects yielding promising results. Our system has the potential to transform the currently used fetal monitoring system to an effective distanced and telematernity care.

8 February 2024 in Physical and Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
NMNastaran Mansourian
Nastaran Mansourian
Sadaf SarafanSadaf Sarafan
Sadaf Sarafan
FAFarah Torkamani Azar
Farah Torkamani Azar
TGTadesse Ghirmai
Tadesse Ghirmai
Hung CaoHung Cao
Hung Cao