Kee Han Kim

Prof. Kee Han Kim

Department of Architectural Engineering, University of Ulsan, Ulsan, South Korea

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2020 in Water
Verified
Journal Article
Open access
PDF file
JRJose Rodriguez
Jose Rodriguez
Joonghyeok HeoJoonghyeok Heo
Joonghyeok Heo
Kee Han KimKee Han Kim
Kee Han Kim
The purpose of this study is to evaluate the impact of hydraulic fracturing on groundwater quality in Ector, Midland, and Martin Counties located in the Permian Basin, West Texas. Chemical fluids used in hydraulic fracturing and groundwater quality parameters (chloride, fluoride, calcium carbonate, nitrate, pH, and total dissolved solids), were statistically analyzed assuming a normal probability function distribution and through a one-way analysis of variance of the parameters. Additionally, the depth of groundwater well versus water quality analysis as well as historical analysis of groundwater quality parameters of wells were performed. The result for each county was individually examined and contrasted with the other two counties, in order to make inferences about groundwater quality and oil and gas activities for the three counties. Potential risks to human health from the abnormal levels of the groundwater quality parameters studied were also discussed based on the Environmental Protection Agency’s (EPA) standards. This research provides important information on groundwater quality in the Permian Basin and contributes on understanding the response to development in hydraulic fracturing.

12 March 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
Kee Han KimKee Han Kim
Kee Han Kim
SJSangsub Jeon
Sangsub Jeon
AIAmina Irakoze
Amina Irakoze
Kiyoung SonKiyoung Son
Kiyoung Son
Recently, the importance of green building certification in consideration of environmentally friendly factors is being emphasized more when constructing buildings in South Korea. The Green Standard for Energy and Environmental Design (G-SEED) is one of the strategies used by the Korean government to effectively reduce building environmental loads. However, due to the large investment needed to acquire green building certification, building owners, stakeholders, and designers often contemplate how to balance G-SEED certification benefits and the additional costs they involve. Therefore, the purpose of this study was to assess the benefits of G-SEED certification in terms of post-occupancy financial advantages through a comparative analysis of real estate prices of apartments in the Yeongnam area. All of the major factors affecting apartment real estate prices in South Korea were considered, and the real estate price difference between G-SEED certified and non-certified apartments was determined through a one-sample t-test. The results demonstrated that G-SEED certified apartment real estate prices were 9.52% higher than non-certified apartments. This study concluded that G-SEED certification–related investment is worth the additional cost as it increases the real estate value of a building.

3 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
DJDong Eun Jung
Dong Eun Jung
CLChanuk Lee
Chanuk Lee
Kee Han KimKee Han Kim
Kee Han Kim
SDSung Lok Do
Sung Lok Do
PV (photovoltaic) systems are receiving the spotlight in Korea due to the Renewable Energy 3020 Implementation Plan (RE3020), which has the goal of reaching 20% for the proportion of renewable energy generation by 2030. Accordingly, the actual performance evaluation of PV systems to achieve the RE3020 has become more important. PV efficiency is mainly determined by various weather conditions (e.g., solar radiation) that affect the power generation of PV systems. However, the efficiency is also affected by changes in module surface temperature. In particular, the efficiency decreases when the module surface temperature rises. That is, the actual PV efficiency falls short of the rated efficiency. The estimation of module surface temperature is critical for evaluating the actual performance of PV systems. Many studies have been conducted to calculate the surface temperature. However, most of the previous studies focused on calculations of current surface temperatures using current environment data, which means that the previous studies have limitations related to timestep. That is, there is a lack of predictive models that calculate the future surface temperatures by using the current measured data. Therefore, this study developed a predictive model using an ANN (artificial neural network) algorithm to determine the surface temperature of PV modules for a future period of time. Then, this study evaluated the actual performance (i.e., power generation) with the predicted surface temperatures.

13 April 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
AIAmina Irakoze
Amina Irakoze
LYlee younga
lee younga
Kee Han KimKee Han Kim
Kee Han Kim
This study evaluated the impact of including a building ceiling depth into a simulation model on skylight efficiency under two climatic conditions (Ulsan and Seoul, South Korea). Using Radiance and EnergyPlus simulation tools integrated in OpenStudio program by National Renewable Energy Laboratory, Golden, Colorado, USA, daylighting and building energy consumption were computed and assessed to evaluate the energy performance and optimization of skylights. Skylight-to-roof ratios from 1% to 25% were analyzed with ceiling depths of 1.5 m to 3 m. The results showed that the range for efficient skylight ratios became smaller with an increase of ceiling depth; in addition, small apertures were more affected by the ceiling depth than were large apertures. Under Ulsan’s climatic conditions, the optimal skylight-to-roof ratios were 8%, 9%, 10%, and 11% for ceiling depths of 1.5 m, 2 m, 2.5 m, and 3 m, respectively. In Seoul, 8% and 9% were the optimum skylight-to-roof ratios for ceiling depths of 1.5 m and 2 m, respectively; no skylight was energy efficient for a ceiling deeper than 2 m. This study indicates that ceiling depth is a critical factor in the evaluation of skylight performance; thus, it should not be excluded from a simulation model, as is often done to simplify simulation modeling.

1 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
CLChanuk Lee
Chanuk Lee
DJDong Eun Jung
Dong Eun Jung
DLDong-Hoon Lee
Dong-Hoon Lee
Kee Han KimKee Han Kim
Kee Han Kim
SDSung Lok Do
Sung Lok Do
In Korea apartment buildings, most energy is consumed as heating energy. In order to reduce heating energy in apartment buildings, it is required to reduce the amount of energy used in heating systems. Energy saving in heating systems can be achieved through operation and control based on efficient operation plans. The efficient operation plan of the heating system should be based on the predicted heating load. Thus, various methods have been developed for predicting heating loads. Recently, artificial intelligence techniques (e.g., ANN: artificial neural network) have been used to predict heating loads. The process for determination of input data variables is necessary to obtain the accuracy of predicted results using an ANN model. However, there is a lack of studies to evaluate the accuracy level of the predicted results caused by the selection and combination of input variables. There is a need to evaluate the performance of an ANN model for prediction of residential heating loads. Therefore, the purpose of this study is, for a residential building, to evaluate the accuracy levels of predicted heating loads using an ANN model with various combinations of input variables. To achieve the study purpose, each case was classified according to the combination of the input variables and the prediction results were analyzed. Through this, the worst, mean, and best were selected according to the predicted performance. In addition, an actual case was selected consisting of variables that can be measured in an actual building. The derived cv(RMSE) of each case resulted in a percentage value of 38.2% for the worst, 7.3% for the mean, 3.0% for the best, and 5.4% for the actual. The largest difference between the best and worst resulted in 33.2%, and thus the precision of the predicted heating loads was highly affected by the selection and combination of the input variables used for the ANN model.

19 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
JYJUNGYEON YU
JUNGYEON YU
AKAngie Kim
Angie Kim
SBSanghwan Bae
Sanghwan Bae
DCDongwoo Cho
Dongwoo Cho
Kee Han KimKee Han Kim
Kee Han Kim
Various problems often arise in high-rise buildings during the winter months due to the stack effect. In this study, the high-rise building of interest, located in South Korea, was experiencing constant loud noises in the winter due to the stack effect. Thus, we created a noise level reduction plan by creating a method for pressurizing the high-rise zones of the building according to outdoor conditions. To discover the appropriate pressurization operating modes, we applied a two-year commissioning process to the 50-story building of interest. The 1st- and 47th-floor elevator halls were identified to have the highest noise levels of all other floors. Prior to applying the reduction plan, the maximum noise level on the first floor with the HVAC system turned off was 85 dB(A) and with the HVAC system turned on it was 70 dB(A). Both values exceeded the criteria of 57 dB(A) for a lobby space of a commercial building. In the case of the 47th floor, the maximum noise level with the HVAC system turned off was 58.7 dB(A) and with the HVAC system turned off was 56.0 dB(A), despite the latter having increased airtightness performance and applying preliminary pressurization (i.e., HVAC operation mode 2). These values exceeded the criteria of 48 dB(A) for an elevator hall in a commercial building. Following this initial data, we determined to pressurize the high/mid-rise zones of the building according to the outdoor air temperature and wind velocity conditions, which we categorized into four types (i.e., HVAC operation mode 4). To this effect, the first-floor elevator hall’s maximum noise level was 56.6 dB(A), meeting the criteria, and the 47th-floor elevator hall’s maximum noise level was 49.5 dB(A), still exceeding the criteria but by an insignificant amount. Although the HVAC pressurization operation we utilized resulted in favorable results for the target building A, it may not be as effective in other new high-rise buildings, creating changes to the indoor air environment or to the energy costs in maintaining a building. However, for the purposes of resolving the stack effect, we believe that the commissioning process we took to optimize the HVAC operation that is presented here can be applied to other new and existing high-rise commercial buildings.