Sanghwan Bae

Dr. Sanghwan Bae

Korea Institute of Civil Engineering & Building Technology

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2022 in Environmental Research
Verified
Journal Article
Open access
Chul KimChul Kim
Chul Kim
JYJungyeon Yu
Jungyeon Yu
YLYun Gyu Lee
Yun Gyu Lee
JKJieun Kim
Jieun Kim
SBSanghwan Bae
Sanghwan Bae
During the last two years, hundreds of millions of people in the world have been infected with SARS-CoV-2 due to recurrent waves and closed spaces. Daycare centers are critical infrastructures that cannot be replaced, even during the COVID-19 period. However, the existing settings in daycare centers may pose risks of inevitable close contact between teachers and children, as well as fomite and airborne transmission during care hours. Therefore, reinforced mitigation strategies have been applied in daycare centers to reduce potential indoor virus transfer in many countries. However, numerous outbreaks of COVID-19 have been reported in daycare centers. Therefore, in this study, researchers focused on the risk and behavior of long-distance virus transmission based on the detected viruses on air purifier filter sampling in a daycare center outbreak in Korea. Various experiments of possible situations were conducted in nursing rooms based on field interviews. The experiments monitored the long-distance transmission behavior of aerosol-sized particles and visualized particle behavior at the daycare center. The results of this study revealed that long-distance virus transmission is possible under the current settings in the daycare center, and flush-out can be an important countermeasure with reinforced ventilation methods to prevent potential airborne spread in the daycare center. The results of air purifiers represented that air purifiers should be properly installed and operated in the daycare center to prevent airborne virus spread by airflow during occupied hours. The findings of this study will contribute to the understanding of airborne virus risk and the development of customized virus measures for daycare centers.

19 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
JYJUNGYEON YU
JUNGYEON YU
AKAngie Kim
Angie Kim
SBSanghwan Bae
Sanghwan Bae
DCDongwoo Cho
Dongwoo Cho
Kee Han KimKee Han Kim
Kee Han Kim
Various problems often arise in high-rise buildings during the winter months due to the stack effect. In this study, the high-rise building of interest, located in South Korea, was experiencing constant loud noises in the winter due to the stack effect. Thus, we created a noise level reduction plan by creating a method for pressurizing the high-rise zones of the building according to outdoor conditions. To discover the appropriate pressurization operating modes, we applied a two-year commissioning process to the 50-story building of interest. The 1st- and 47th-floor elevator halls were identified to have the highest noise levels of all other floors. Prior to applying the reduction plan, the maximum noise level on the first floor with the HVAC system turned off was 85 dB(A) and with the HVAC system turned on it was 70 dB(A). Both values exceeded the criteria of 57 dB(A) for a lobby space of a commercial building. In the case of the 47th floor, the maximum noise level with the HVAC system turned off was 58.7 dB(A) and with the HVAC system turned off was 56.0 dB(A), despite the latter having increased airtightness performance and applying preliminary pressurization (i.e., HVAC operation mode 2). These values exceeded the criteria of 48 dB(A) for an elevator hall in a commercial building. Following this initial data, we determined to pressurize the high/mid-rise zones of the building according to the outdoor air temperature and wind velocity conditions, which we categorized into four types (i.e., HVAC operation mode 4). To this effect, the first-floor elevator hall’s maximum noise level was 56.6 dB(A), meeting the criteria, and the 47th-floor elevator hall’s maximum noise level was 49.5 dB(A), still exceeding the criteria but by an insignificant amount. Although the HVAC pressurization operation we utilized resulted in favorable results for the target building A, it may not be as effective in other new high-rise buildings, creating changes to the indoor air environment or to the energy costs in maintaining a building. However, for the purposes of resolving the stack effect, we believe that the commissioning process we took to optimize the HVAC operation that is presented here can be applied to other new and existing high-rise commercial buildings.

31 December 2025 in Journal of Odor and Indoor Environment
Verified
Journal Article
Closed access
SBSanghwan Bae
Sanghwan Bae
JYJungyeon Yu
Jungyeon Yu
SKSu Jin Kang
Su Jin Kang
YSYeong-Jun Song
Yeong-Jun Song
SLSang-Eun Lee
Sang-Eun Lee
YPYoung-Joon Park
Young-Joon Park

31 December 2025 in Journal of Odor and Indoor Environment
Verified
Journal Article
Closed access
SBSanghwan Bae
Sanghwan Bae
JYJungyeon Yu
Jungyeon Yu

30 June 2026 in Journal of Odor and Indoor Environment
Verified
Journal Article
Closed access
SBSanghwan Bae
Sanghwan Bae
JYJungyeon Yu
Jungyeon Yu
SKSu Jin Kang
Su Jin Kang
SCSoo Hyeon Cho
Soo Hyeon Cho
SLSang-Eun Lee
Sang-Eun Lee
YPYoung-Joon Park
Young-Joon Park