Cephalosporins type antibiotics are widely used to treat infectious diseases. Their determination is not only important in blood/serum of patients under treatment but also in diverse matrices like wastewaters, milk etc. as contaminant. Keeping in view the need, a new high performance liquid chromatographic method for the determination of three cephalosporins (cefradine, cefuroxime and cefotaxime) has been developed. Separation was performed on an ODS column with binary solvent elution of aqueous formic acid (0.05%) and methanol in the ratio of 45: 55 (v/v) at a flow rate of 1 mL min-1 and UV detection at 260 nm. Under optimised conditions, all three cephalosporins were baseline separated within 5 min. Linear responses for cefradine 5–20 μg mL-1, cefuroxime 0.5-15 μg mL-1 and cefotaxime 1.0-20 μg mL-1 were established. LOD of 0.05-0.25 μg mL-1 after preconcentration was achieved. The method was applied to serum samples of patients under treatment with these antibiotics and to screen the selected cephalosporins from hospital wastewater and milk samples. Moreover, method was applied to study stability of aqueous solutions and acid/base induced degradation of all three drugs.
In this study, composite polymeric cryogel cartridges were achieved by using Cd(II) imprinted poly(hydroxyethyl methacrylate N-methacryloly-(L)-cysteine methylester) beads and poly(hydroxyethyl methacrylate) cryogel cartridges with two different mole ratios of functional monomer. The N-methacryloly-(L)-cysteinemethylester was used as a functional monomer and Cd(II) 1:1 and 2:1, which were then notated as MIP1 and MIP2, respectively. Various characterization methods have confirmed the structural transformation on the MIP1 and MIP2 composite cryogel cartridges by scanning electron microscopy, Fourier-transform infrared spectroscopy-Attenuated Total Reflectance, and swelling tests. The maximum amount of Cd(II) adsorption with composite cryogel cartridges was determined by altering the Cd(II) initial concentration, temperature, and pH values. The maximum adsorption capacity of MIP1 and MIP2 composite cryogel cartridges obtained was 76.35 and 98.8 µmol/g of composite cryogels, respectively. The adsorption studies revealed that the MIP2 possessed a good adsorption performance for Cd(II). The obtained composite cryogel cartridges have a selective, reusable, and cost-friendly potential for the removal of Cd(II) from aqueous solutions, and are used many times without decreasing their adsorption capacities significantly. The Cd(II) removal rate of the MIP1 and MIP2 composite cryogel cartridges from synthetic wastewater samples was determined as 98.8%. The obtained cryogel cartridges’ adsorption material exhibited a good directional removal performance for Cd(II) from wastewater samples.