Edoardo Charbon

Dr. Edoardo Charbon

Chair of VLSI Design, Department of Microelectronics, Delft University of Technology, Delft, Netherlands

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2021 in Nature Electronics
Verified
Journal Article
Closed access
PDF file
MGM. F. Gonzalez-Zalba
M. F. Gonzalez-Zalba
SFS. de Franceschi
S. de Franceschi
Edoardo CharbonEdoardo Charbon
Edoardo Charbon
TMT. Meunier
T. Meunier
MVM. Vinet
M. Vinet
ADA. S. Dzurak
A. S. Dzurak

12 May 2021 in Nature
Verified
Journal Article
Closed access
PDF file
XXXiao Xue
Xiao Xue
BPBishnu Patra
Bishnu Patra
JDJeroen P. G. van Dijk
Jeroen P. G. van Dijk
NSNodar Samkharadze
Nodar Samkharadze
SSSushil Subramanian
Sushil Subramanian
LVLieven M. K. Vandersypen
Lieven M. K. Vandersypen

22 October 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
PLPaul LECOQ
Paul LECOQ
CMChristian Morel
Christian Morel
John PriorJohn Prior
John Prior
DVDimitris Visvikis
Dimitris Visvikis
SGStefan Gundacker
Stefan Gundacker
MBMathieu Benoit
Mathieu Benoit
Since the seventies, positron emission tomography (PET) has become an invaluable medical molecular imaging modality with an unprecedented sensitivity at the picomolar level, especially for cancer diagnosis and the monitoring of its response to therapy. More recently, its combination with x-ray computed tomography (CT) or magnetic resonance (MR) has added high precision anatomic information in fused PET/CT and PET/MR images, thus compensating for the modest intrinsic spatial resolution of PET. Nevertheless, a number of medical challenges call for further improvements in PET sensitivity. These concern in particular new treatment opportunities in the context personalized (also called precision) medicine, such as the need to dynamically track a small number of cells in cancer immunotherapy or stem cells for tissue repair procedures. A better signal-to-noise ratio (SNR) in the image would allow detecting smaller size tumours together with a better staging of the patients, thus increasing the chances of putting cancer in complete remission. Moreover, there is an increasing demand for reducing the radioactive doses injected to the patients without impairing image quality. There are three ways to improve PET scanner sensitivity: improving detector efficiency, increasing geometrical acceptance of the imaging device and pushing the timing performance of the detectors. Currently, some pre-localization of the electron-positron annihilation along a line-of-response (LOR) given by the detection of a pair of annihilation photons is provided by the detection of the time difference between the two photons, also known as the time-of-flight (TOF) difference of the photons, whose accuracy is given by the coincidence time resolution (CTR). A CTR of about 10 picoseconds FWHM will ultimately allow to obtain a direct 3D volume representation of the activity distribution of a positron emitting radiopharmaceutical, at the millimetre level, thus introducing a quantum leap in PET imaging and quantification and fostering more frequent use of 11 C radiopharmaceuticals. The present roadmap article toward the advent of 10 ps TOF-PET addresses the status and current/future challenges along the development of TOF-PET with the objective to reach this mythic 10 ps frontier that will open the door to real-time volume imaging virtually without tomographic inversion. The medical impact and prospects to achieve this technological revolution from the detection and image reconstruction point-of-views, together with a few perspectives beyond the TOF-PET application are discussed.

28 December 2018 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
CZChao Zhang
Chao Zhang
SLScott Lindner
Scott Lindner
IAIvan Michel Antolovic
Ivan Michel Antolovic
JPJuan Mata Pavia
Juan Mata Pavia
MWMartin Wolf
Martin Wolf
Edoardo CharbonEdoardo Charbon
Edoardo Charbon

28 August 2018 in IEEE Journal of Selected Topics in Quantum Electronics
Verified
Journal Article
Open access
AUArin Can Ulku
Arin Can Ulku
CBClaudio Bruschini
Claudio Bruschini
IAIvan Michel Antolovic
Ivan Michel Antolovic
YKYung Kuo
Yung Kuo
RARinat Ankri
Rinat Ankri
Edoardo CharbonEdoardo Charbon
Edoardo Charbon
In this paper, we report on SwissSPAD2, an image sensor with 512 × 512 photon-counting pixels, each comprising a single-photon avalanche diode (SPAD), a 1-b memory, and a gating mechanism capable of turning the SPAD on and off, with a skew of 250 and 344 ps, respectively, for a minimum duration of 5.75 ns. The sensor is designed to achieve a frame rate of up to 97 700 binary frames per second and sub-40 ps gate shifts. By synchronizing it with a pulsed laser and using multiple successive overlapping gates, one can reconstruct a molecule's fluorescent response with picosecond temporal resolution. Thanks to the sensor's number of pixels (the largest to date) and the fully integrated gated operation, SwissSPAD2 enables widefield fluorescence lifetime imaging microscopy with an all-solid-state solution and at relatively high frame rates. This was demonstrated with preliminary results on organic dyes and semiconductor quantum dots using both decay fitting and phasor analysis. Furthermore, pixels with an exceptionally low dark count rate and high photon detection probability enable uniform and high-quality imaging of biologically relevant fluorescent samples stained with multiple dyes. While future versions will feature the addition of microlenses and optimize firmware speed, our results open the way for low-cost alternatives to commercially available scientific time-resolved imagers.

29 September 2020 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Open access
JDJeroen Petrus Gerardus Van Dijk
Jeroen Petrus Gerardus Van Dijk
BPBishnu Patra
Bishnu Patra
SSSushil Subramanian
Sushil Subramanian
XXXiao Xue
Xiao Xue
NSNodar Samkharadze
Nodar Samkharadze
FSFabio Sebastiano
Fabio Sebastiano
Building a large-scale quantum computer requires the co-optimization of both the quantum bits (qubits) and their control electronics. By operating the CMOS control circuits at cryogenic temperatures (cryo-CMOS), and hence in close proximity to the cryogenic solid-state qubits, a compact quantum-computing system can be achieved, thus promising scalability to the large number of qubits required in a practical application. This work presents a cryo-CMOS microwave signal generator for frequency-multiplexed control of 4x 32 qubits (32 qubits per RF output). A digitally intensive architecture offering full programmability of phase, amplitude, and frequency of the output microwave pulses and a wideband RF front end operating from 2 to 20 GHz allow targeting both spin qubits and transmons. The controller comprises a qubit-phase-tracking direct digital synthesis (DDS) back end for coherent qubit control and a single-sideband (SSB) RF front end optimized for minimum leakage between the qubit channels. Fabricated in Intel 22-nm FinFET technology, it achieves a 48-dB SNR and 45-dB spurious-free dynamic range (SFDR) in a 1-GHz data bandwidth when operating at 3 K, thus enabling high-fidelity qubit control. By exploiting the on-chip 4096-instruction memory, the capability to translate quantum algorithms to microwave signals has been demonstrated by coherently controlling a spin qubit at both 14 and 18 GHz.