Nico Lanconelli

Prof. Nico Lanconelli


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2012 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
NLNico Lanconelli
Nico Lanconelli
MPM Pacilio
M Pacilio
SMS Lo Meo
S Lo Meo
FBF Botta
F Botta
ADA Di Dia
A Di Dia
MCM Cremonesi
M Cremonesi
The increasing availability of SPECT/CT devices with advanced technology offers the opportunity for the accurate assessment of the radiation dose to the biological target volume during radionuclide therapy. Voxel dosimetry can be performed employing direct Monte Carlo radiation transport simulations, based on both morphological and functional images of the patient. On the other hand, for voxel dosimetry calculations the voxel S value method can be considered an easier approach than patient-specific Monte Carlo simulations, ensuring a good dosimetric accuracy at least for anatomic regions which are characterized by uniform density tissue. However, this approach has been limited because of the lack of tabulated S values for different voxel dimensions and radionuclides. The aim of this work is to provide a free dataset of values which can be used for voxel dosimetry in targeted radionuclide studies. Seven different radionuclides (89Sr, 90Y, 131I, 153Sm, 177Lu, 186Re, 188Re), and 13 different voxel sizes (2.21, 2.33, 2.4, 3, 3.59, 3.9, 4, 4.42, 4.8, 5, 6, 6.8 and 9.28 mm) are considered. Voxel S values are calculated performing simulations of monochromatic photon and electron sources in two different homogeneous tissues (soft tissue and bone) with DOSXYZnrc code, and weighting the contributions on the basis of the radionuclide emission spectra. The outcomes are validated by comparison with Monte Carlo simulations obtained with other codes (PENELOPE and MCNP4c) performing direct simulation of the radionuclide emission spectra. The differences among the different Monte Carlo codes are of the order of a few per cent when considering the source voxel and the bremsstrahlung tail, whereas the highest differences are observed at a distance close to the maximum continuous slowing down approximation range of electrons. These discrepancies would negligibly affect dosimetric assessments. The dataset of voxel S values can be freely downloaded from the website www.medphys.it.

1 July 2009 in Journal of Instrumentation
Verified
Journal Article
Open access
SMS Lo Meo
S Lo Meo
PBP Bennati
P Bennati
MCM N Cinti
M N Cinti
NLNico Lanconelli
Nico Lanconelli
FNF L Navarria
F L Navarria
FVF Vittorini
F Vittorini

30 June 2013 in Physica Medica
Verified
Journal Article
Closed access
PDF file
NLNico Lanconelli
Nico Lanconelli
GMGiovanni Mettivier
Giovanni Mettivier
SMSergio Lo Meo
Sergio Lo Meo
PRPaolo Russo
Paolo Russo

23 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Alessia MilanoAlessia Milano
Alessia Milano
AGAlex Vergara Gil
Alex Vergara Gil
EFEnrico Fabrizi
Enrico Fabrizi
MCMarta Cremonesi
Marta Cremonesi
IVIvan Veronese
Ivan Veronese
MPMassimiliano Pacilio
Massimiliano Pacilio
The aim was the validation of a platform for internal dosimetry, named MCID, based on patient-specific images and direct Monte Carlo (MC) simulations, for radioembolization of liver tumors with 90Y-labeled microspheres. CT of real patients were used to create voxelized phantoms with different density and activity maps. SPECT acquisitions were simulated by the SIMIND MC code. Input macros for the GATE/Geant4 code were generated by MCID, loading coregistered morphological and functional images and performing image segmentation. The dosimetric results obtained from the direct MC simulations and from conventional MIRD approach at both organ and voxel level, in condition of homogeneous tissues, were compared, obtaining differences of about 0.3% and within 3%, respectively, whereas differences increased (up to 14%) introducing tissue heterogeneities in phantoms. Mean absorbed dose for spherical regions of different sizes (10 mm ≤ r ≤ 30 mm) from MC code and from OLINDA/EXM were also compared obtaining differences varying in the range 7–69%, which decreased to 2–9% after correcting for partial volume effects (PVEs) from imaging, confirming that differences were mostly due to PVEs, even though a still high difference for the smallest sphere suggested possible source description mismatching. This study validated the MCID platform, which allows the fast implementation of a patient-specific GATE simulation, avoiding complex and time-consuming manual coding. It also points out the relevance of personalized dosimetry, accounting for inhomogeneities, in order to avoid absorbed dose misestimations.

1 January 2011 in Journal of Instrumentation
Verified
Journal Article
Closed access
ACA Cornelio
A Cornelio
FGF Gasperini
F Gasperini
SMS Lo Meo
S Lo Meo
NLNico Lanconelli
Nico Lanconelli
SMS Moehrs
S Moehrs
AGA Del Guerra
A Del Guerra

1 December 2009 in Acta Radiologica
Verified
Journal Article
Closed access
SRS. Rivetti
S. Rivetti
BCB. Canossi
B. Canossi
RBR. Battista
R. Battista
NLNico Lanconelli
Nico Lanconelli
EVE. Vetruccio
E. Vetruccio
PTP. Torricelli
P. Torricelli
Background: Digital mammography systems, thanks to a physical performance better than conventional screen-film units, have the potential of reducing the dose to patients, without decreasing the diagnostic accuracy. Purpose: To achieve a physical and clinical comparison between two systems: a screen-film plate and a dual-side computed radiography system (CRM; FUJIFILM FCR 5000 MA). Material and Methods: A unique feature of the FCR 5000 MA system is that it has a clear support medium, allowing light emitted during the scanning process to be detected on the "back" of the storage phosphor plate, considerably improving the system's efficiency. The system's physical performance was tested by means of a quantitative analysis, with calculation of the modulation transfer function, detective quantum efficiency, and contrast-detail analysis; subsequently, the results were compared with those achieved using a screen-film system (SFM; Eastmann Kodak MinR-MinR 2000). A receiver operating characteristic (ROC) analysis was then performed on 120 paired clinical images obtained in a craniocaudal projection with the conventional SFM system under standard exposure conditions and also with the CRM system working with a dose reduced by 35% (average breast thickness: 4.3 cm; mean glandular dose: 1.45 mGy). CRM clinical images were interpreted both in hard copy and in soft copy. Results: The ROC analysis revealed that the performances of the two systems (SFM and CRM with reduced dose) were similar ( P>0.05): the diagnostic accuracy of the two systems, when valued in terms of the area underneath the ROC curve, was found to be 0.74 for the SFM, 0.78 for the CRM (hard copy), and 0.79 for the CRM (soft copy). Conclusion: The outcome obtained from our experiments shows that the use of the dual-side CRM system is a very good alternative to the screen-film system.