Sebastian Abegg

Mr. Sebastian Abegg

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2019 in ACS Sensors
Verified
Journal Article
Closed access
AGAndreas Guentner
Andreas Guentner
SASebastian Abegg
Sebastian Abegg
KKKarsten Königstein
Karsten Königstein
PGPhilipp Gerber
Philipp Gerber
Arno Schmidt-TrucksässArno Schmidt-Trucksäss
Arno Schmidt-Trucksäss
SPSotiris E. Pratsinis
Sotiris E. Pratsinis

16 September 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
JBJ. van Den Broek
J. van Den Broek
SASebastian Abegg
Sebastian Abegg
SPSotiris E. Pratsinis
Sotiris E. Pratsinis
AGAndreas Guentner
Andreas Guentner
Methanol poisoning causes blindness, organ failure or even death when recognized too late. Currently, there is no methanol detector for quick diagnosis by breath analysis or for screening of laced beverages. Typically, chemical sensors cannot distinguish methanol from the much higher ethanol background. Here, we present an inexpensive and handheld sensor for highly selective methanol detection. It consists of a separation column (Tenax) separating methanol from interferants like ethanol, acetone or hydrogen, as in gas chromatography, and a chemoresistive gas sensor (Pd-doped SnO2 nanoparticles) to quantify the methanol concentration. This way, methanol is measured within 2 min from 1 to 1000 ppm without interference of much higher ethanol levels (up to 62,000 ppm). As a proof-of-concept, we reliably measure methanol concentrations in spiked breath samples and liquor. This could enable the realization of highly selective sensors in emerging applications such as breath analysis or air quality monitoring.

1 March 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
AGAndreas Guentner
Andreas Guentner
SASebastian Abegg
Sebastian Abegg
KWKarsten Wegner
Karsten Wegner
SPSotiris E. Pratsinis
Sotiris E. Pratsinis

15 June 2020 in Nature Food
Verified
Journal Article
Closed access
PDF file
SASebastian Abegg
Sebastian Abegg
LMLeandro Magro
Leandro Magro
JBJan van Den Broek
Jan van Den Broek
SPSotiris E. Pratsinis
Sotiris E. Pratsinis
AGAndreas Guentner
Andreas Guentner

16 June 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SASebastian Abegg
Sebastian Abegg
DCDavid Klein Cerrejon
David Klein Cerrejon
AGAndreas Guentner
Andreas Guentner
SPSotiris E. Pratsinis
Sotiris E. Pratsinis
Nitrogen dioxide (NO2) is a major air pollutant resulting in respiratory problems, from wheezing, coughing, to even asthma. Low-cost sensors based on WO3 nanoparticles are promising due to their distinct selectivity to detect NO2 at the ppb level. Here, we revealed that controlling the thickness of highly porous (97%) WO3 films between 0.5 and 12.3 μm altered the NO2 sensitivity by more than an order of magnitude. Therefore, films of WO3 nanoparticles (20 nm in diameter by N2 adsorption) with mixed γ- and ε-phase were deposited by single-step flame spray pyrolysis without affecting crystal size, phase composition, and film porosity. That way, sensitivity and selectivity effects were associated unambiguously to thickness, which was not possible yet with other sensor fabrication methods. At the optimum thickness (3.1 μm) and 125 °C, NO2 concentrations were detected down to 3 ppb at 50% relative humidity (RH), and outstanding NO2 selectivity to CO, methanol, ethanol, NH3 (all > 105), H2, CH4, acetone (all > 104), formaldehyde (>103), and H2S (835) was achieved. Such thickness-optimized and porous WO3 films have strong potential for integration into low-power devices for distributed NO2 air quality monitoring.

1 October 2017
Verified
Conference Paper
Closed access
DPDetlef Pape
Detlef Pape
SASebastian Abegg
Sebastian Abegg
LBLouis-Philippe Bibeau
Louis-Philippe Bibeau
AOAlex Ouellet-Belanger
Alex Ouellet-Belanger
Dissolved gas in oil analysis is a key measure to determine the status and the health state of power transformers. Different sensors and devices have been developed in the past for continuous on-line monitoring of these gas concentrations. A critical point for these measurements is a good exchange of the oil at the sensor with the oil in the main circulation of the transformer. Due to the low diffusion of the gasses in oil strong gradients of the gas concentration can occur in the different parts of the transformers. Therefore, a thermal pump will be investigated here for providing a strong oil exchange between the sensor and the main transformer part. The pump will be tested under different installation conditions and its fast response time to concentration changes can be shown under these different installations.