Nitrogen dioxide (NO2) is a major air pollutant resulting in respiratory problems, from wheezing, coughing, to even asthma. Low-cost sensors based on WO3 nanoparticles are promising due to their distinct selectivity to detect NO2 at the ppb level. Here, we revealed that controlling the thickness of highly porous (97%) WO3 films between 0.5 and 12.3 μm altered the NO2 sensitivity by more than an order of magnitude. Therefore, films of WO3 nanoparticles (20 nm in diameter by N2 adsorption) with mixed γ- and ε-phase were deposited by single-step flame spray pyrolysis without affecting crystal size, phase composition, and film porosity. That way, sensitivity and selectivity effects were associated unambiguously to thickness, which was not possible yet with other sensor fabrication methods. At the optimum thickness (3.1 μm) and 125 °C, NO2 concentrations were detected down to 3 ppb at 50% relative humidity (RH), and outstanding NO2 selectivity to CO, methanol, ethanol, NH3 (all > 105), H2, CH4, acetone (all > 104), formaldehyde (>103), and H2S (835) was achieved. Such thickness-optimized and porous WO3 films have strong potential for integration into low-power devices for distributed NO2 air quality monitoring.
The buccal mucosa is a highly interesting site for non-invasive drug delivery due to its relatively permeable epithelium and good accessibility. Recently, device-based systems have enabled the delivery of macromolecular drugs by leveraging mechanical stretching forces on the tissue to assist drug diffusion. Despite the successful exploitation of the buccal route with such systems, the biomechanics of buccal tissue are still poorly characterized and understood due to a lack of adequate characterization methods. Therefore, we propose a combination of physiological tissue modeling with simple suction experiments as a tool for characterizing and understanding the buccal tissue under the impact of negative pressure. Here, we present an initial step towards a multiphasic and poroelastic model specifically designed for the non-keratinized buccal tissue under the impact of negative pressure. A validated finite element model (FEM) for human skin was adapted to represent the histological structure of porcine buccal tissue. We performed suction experiments using the NIMBLE device, specifically developed for measuring skin stiffness, to characterize its mechanical behavior and train the FEM model. The resulting simulation tracks essential physiological parameters and allows the prediction of measurable changes in the tissue, such as the thinning of the epithelium and single-cell stretching. The FEM simulation was validated through histochemically stained tissue sections at the NIMBLE application site. A good correlation was demonstrated between predicted and experimentally observed changes. This work serves as a first step towards a computational representation of buccal tissue under the impact of negative pressure.