Background: The aim of this study is to evaluate the accuracy of a Liquid Crystal Display (LCD) 3D printer compared to a Direct Light Processing (DLP) 3D printer for dental model printing. Methods: Two different printers in terms of 3D printing technology were used in this study. One was a DLP 3D printer and one an LCD 3D printer. The accuracy of the printers was evaluated in terms of trueness and precision. Ten STL reference files were used for this study. For trueness, each STL file was printed once with each 3D printer. For precision, one randomly chosen STL file was printed 10 times with each 3D printer. Afterward, the models were scanned with a model scanner, and reverse engineering software was used for the STL comparisons. Results: In terms of trueness, the comparison between the LCD 3D printer and DLP 3D printer was statistically significant, with a p-value = 0.004. For precision, the comparison between the LCD 3D printer and the DLP 3D printer was statistically significant, with a p-value = 0.011. Conclusions: The DLP 3D printer is more accurate in terms of dental model printing than the LCD 3D printer. However, both DLP and LCD printers can accurately be used to print dental models for the fabrication of orthodontic appliances.
Background: The use of digital technology has exponentially increased over recent years. Intraoral scanners, especially, have gained traction within orthodontics. The objective of the present review is to investigate the available evidence to create an up-to-date presentation of various clinical aspects of intraoral scanners in orthodontics. Methods: Search without restrictions in seven databases (Pubmed, CENTRAL, Cochrane Reviews, Scopus, Web of Science, Clinical Trials, Proquest) since inception, and hand searching until October 2020, were conducted. Results: The majority of studies were either cross-over or parallel group studies. The accuracy and reproducibility of intraoral scanners, in comparison to conventional methods, were investigated in several studies, with controversial results. The duration of the procedure did not report any clear outcome in favor of any method. Patients seem to prefer intraoral scanning, even though numerous studies point out the importance of operators’ experience and skills. Conclusions: Despite the innovations that intraoral scanners have brought in orthodontic clinical practice, there are still some challenges and limitations in their use. The majority of existing limitations may be overcome with experience and good clinical skills. More high-quality studies need to be conducted so that clinicians can have a clear image of this new technology.
Background: Three-dimensional printing technology is an additive manufacturing technology that is used to reconstruct 3D objects. In the last decade, it has been rapidly involved in dentistry and in orthodontics. This article aims to review the literature and present the accuracy of different 3D printer types and any factors that could affect the 3D printing of dental models in the orthodontic field. Methods: The search strategy of this systematic review included keywords in combination with MeSH terms in Medline, Scopus, and Cochrane Library until June 2022 and only in English. Results: Eleven articles were selected for our study. All the articles were in vitro prospective studies, and they presented a low risk of bias. The results suggested that the accuracy of a printed dental cast can be affected by the different types of 3D technologies, the dental cast’s base design, and the printing materials. The accuracy appears to not be affected by the layer height and the position of the model on the building template. Conclusions: According to this systematic review, all different types of 3D technology can produce clinically accepted results for orthodontic purposes. There is a need for more studies to clarify the accuracy and added value of 3D printing technology in orthodontics.
The achievement of aesthetic, functional occlusion should not mark the end of the orthodontic intervention. To prevent relapse, retention needs advance planning, and may vary in duration. This review aims to present and comment on the available means of retention. The ever-popular, passive Hawley-like removable appliances are credible in maintaining the desired occlusion. Modifications are the removable appliance Wrap Around, having the labial archwire extending to the premolars; the translucent retainer, Astics, a unique aesthetic Hawley-type device; and the reinforced removable retainer, which features a metallic grid reinforcing the acrylic base. Vacuum-formed retainers are easy to fabricate and are readily prescribed. By contrast, fixed retainers are made of orthodontic wire and composite resin bonded on the lingual or palatal surfaces of the anterior teeth. Patient-related variables need evaluation to select the appropriate retainer, while patients ought to realize the importance of retention and comply with offered guidance. Overall, the orthodontist is responsible for keeping the patient informed on the properties and the duration of retention, even before starting active orthodontic treatment.
Background: This study aims to compare an automated cephalometric analysis based on the latest deep learning method of automatically identifying cephalometric landmarks with a manual tracing method using broadly accepted cephalometric software. Methods: A total of 100 cephalometric X-rays taken using a CS8100SC cephalostat were collected from a private practice. The X-rays were taken in maximum image size (18 × 24 cm lateral image). All cephalometric X-rays were first manually traced using the Dolphin 3D Imaging program version 11.0 and then automatically, using the Artificial Intelligence CS imaging V8 software. The American Board of Orthodontics analysis and the European Board of Orthodontics analysis were used for the cephalometric measurements. This resulted in the identification of 16 cephalometric landmarks, used for 16 angular and 2 linear measurements. Results: All measurements showed great reproducibility with high intra-class reliability (>0.97). The two methods showed great agreement, with an ICC range of 0.70–0.92. Mean values of SNA, SNB, ANB, SN-MP, U1-SN, L1-NB, SNPg, ANPg, SN/ANS-PNS, SN/GoGn, U1/ANS-PNS, L1-APg, U1-NA, and L1-GoGn landmarks had no significant differences between the two methods (p > 0.0027), while the mean values of FMA, L1-MP, ANS-PNS/GoGn, and U1-L1 were statistically significantly different (p < 0.0027). Conclusions: The automatic cephalometric tracing method using CS imaging V8 software is reliable and accurate for all cephalometric measurements.
Dental eruption refers to the vertical displacement of a tooth from its initial non-functional towards its functional position. Tooth eruption disorders may be expressed in various clinical conditions, which may be grouped as “primary retention” and “secondary retention”. The purpose of this article is to review the literature and the clinical parameters of the various conditions related to tooth eruption disorders. Materials and Methods: The search strategy of this critical review included keywords in combination with MeSH terms in Medline, Scopus, and Cochrane Library until February 2022 and only in English. Results: “Primary Failure of Eruption” (PFE) occurs during the eruption process and includes clinical characteristics of both primary and secondary retention, which make diagnosis difficult. PFE is distinguished by Types I and II. In Type I, the defect in the eruption process occurs in all the relative teeth at the same time, whilst in Type II, the clinical expressions vary in multiple quadrants of the mouth, and the second molars erupt more. The variability of the PFE’s clinical spectrum seems to be connected to a genetic origin. The differential diagnosis among single ankylosis, secondary retention, and PFE is based on the occlusal relationship between the upper and the lower teeth distally, most commonly the first molar, which has not yet fully erupted. The treatment approach depends on many factors and combines surgical and orthodontic techniques.