Ioannis A. Tsolakis

Dr. Ioannis A. Tsolakis

Aristotle University of Thessaloniki, Thessaloníki, Kentrikí Makedonía, Greece
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Ioannis A. TsolakisIoannis A. Tsolakis
Ioannis A. Tsolakis
William PapaioannouWilliam Papaioannou
William Papaioannou
EPErofili Papadopoulou
Erofili Papadopoulou
MDMaria Dalampira
Maria Dalampira
Apostolos TsolakisApostolos Tsolakis
Apostolos Tsolakis
Background: The aim of this study is to evaluate the accuracy of a Liquid Crystal Display (LCD) 3D printer compared to a Direct Light Processing (DLP) 3D printer for dental model printing. Methods: Two different printers in terms of 3D printing technology were used in this study. One was a DLP 3D printer and one an LCD 3D printer. The accuracy of the printers was evaluated in terms of trueness and precision. Ten STL reference files were used for this study. For trueness, each STL file was printed once with each 3D printer. For precision, one randomly chosen STL file was printed 10 times with each 3D printer. Afterward, the models were scanned with a model scanner, and reverse engineering software was used for the STL comparisons. Results: In terms of trueness, the comparison between the LCD 3D printer and DLP 3D printer was statistically significant, with a p-value = 0.004. For precision, the comparison between the LCD 3D printer and the DLP 3D printer was statistically significant, with a p-value = 0.011. Conclusions: The DLP 3D printer is more accurate in terms of dental model printing than the LCD 3D printer. However, both DLP and LCD printers can accurately be used to print dental models for the fabrication of orthodontic appliances.

23 July 2022 in Children
Verified
Journal Article
Open access
PDF file
Ioannis A. TsolakisIoannis A. Tsolakis
Ioannis A. Tsolakis
SGSotiria Gizani
Sotiria Gizani
NEARCHOS PANAYINEARCHOS PANAYI
NEARCHOS PANAYI
GAGeorgios Antonopoulos
Georgios Antonopoulos
Apostolos TsolakisApostolos Tsolakis
Apostolos Tsolakis
Background: Three-dimensional printing technology is an additive manufacturing technology that is used to reconstruct 3D objects. In the last decade, it has been rapidly involved in dentistry and in orthodontics. This article aims to review the literature and present the accuracy of different 3D printer types and any factors that could affect the 3D printing of dental models in the orthodontic field. Methods: The search strategy of this systematic review included keywords in combination with MeSH terms in Medline, Scopus, and Cochrane Library until June 2022 and only in English. Results: Eleven articles were selected for our study. All the articles were in vitro prospective studies, and they presented a low risk of bias. The results suggested that the accuracy of a printed dental cast can be affected by the different types of 3D technologies, the dental cast’s base design, and the printing materials. The accuracy appears to not be affected by the layer height and the position of the model on the building template. Conclusions: According to this systematic review, all different types of 3D technology can produce clinically accepted results for orthodontic purposes. There is a need for more studies to clarify the accuracy and added value of 3D printing technology in orthodontics.

1 October 2016 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
Ioannis A. TsolakisIoannis A. Tsolakis
Ioannis A. Tsolakis
DVDivya Venkat
Divya Venkat
MHMark G. Hans
Mark G. Hans
AAAurelio Alonso
Aurelio Alonso
JPJ. Martin Palomo
J. Martin Palomo

28 January 2023 in Children
Verified
Journal Article
Open access
PDF file
Ioannis LyrosIoannis Lyros
Ioannis Lyros
Ioannis A. TsolakisIoannis A. Tsolakis
Ioannis A. Tsolakis
MMMichael P. Maroulakos
Michael P. Maroulakos
EFEleni Fora
Eleni Fora
TLTheodoros Lykogeorgos
Theodoros Lykogeorgos
Apostolos TsolakisApostolos Tsolakis
Apostolos Tsolakis
The achievement of aesthetic, functional occlusion should not mark the end of the orthodontic intervention. To prevent relapse, retention needs advance planning, and may vary in duration. This review aims to present and comment on the available means of retention. The ever-popular, passive Hawley-like removable appliances are credible in maintaining the desired occlusion. Modifications are the removable appliance Wrap Around, having the labial archwire extending to the premolars; the translucent retainer, Astics, a unique aesthetic Hawley-type device; and the reinforced removable retainer, which features a metallic grid reinforcing the acrylic base. Vacuum-formed retainers are easy to fabricate and are readily prescribed. By contrast, fixed retainers are made of orthodontic wire and composite resin bonded on the lingual or palatal surfaces of the anterior teeth. Patient-related variables need evaluation to select the appropriate retainer, while patients ought to realize the importance of retention and comply with offered guidance. Overall, the orthodontist is responsible for keeping the patient informed on the properties and the duration of retention, even before starting active orthodontic treatment.

20 November 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Ioannis A. TsolakisIoannis A. Tsolakis
Ioannis A. Tsolakis
Apostolos TsolakisApostolos Tsolakis
Apostolos Tsolakis
TETarek ElShebiny
Tarek ElShebiny
SMStefanos Matthaios
Stefanos Matthaios
Juan PalomoJuan Palomo
Juan Palomo
Background: This study aims to compare an automated cephalometric analysis based on the latest deep learning method of automatically identifying cephalometric landmarks with a manual tracing method using broadly accepted cephalometric software. Methods: A total of 100 cephalometric X-rays taken using a CS8100SC cephalostat were collected from a private practice. The X-rays were taken in maximum image size (18 × 24 cm lateral image). All cephalometric X-rays were first manually traced using the Dolphin 3D Imaging program version 11.0 and then automatically, using the Artificial Intelligence CS imaging V8 software. The American Board of Orthodontics analysis and the European Board of Orthodontics analysis were used for the cephalometric measurements. This resulted in the identification of 16 cephalometric landmarks, used for 16 angular and 2 linear measurements. Results: All measurements showed great reproducibility with high intra-class reliability (>0.97). The two methods showed great agreement, with an ICC range of 0.70–0.92. Mean values of SNA, SNB, ANB, SN-MP, U1-SN, L1-NB, SNPg, ANPg, SN/ANS-PNS, SN/GoGn, U1/ANS-PNS, L1-APg, U1-NA, and L1-GoGn landmarks had no significant differences between the two methods (p > 0.0027), while the mean values of FMA, L1-MP, ANS-PNS/GoGn, and U1-L1 were statistically significantly different (p < 0.0027). Conclusions: The automatic cephalometric tracing method using CS imaging V8 software is reliable and accurate for all cephalometric measurements.

9 May 2017 in European Journal of Orthodontics
Verified
Journal Article
Closed access
PDF file
DSDimitrios Sampaziotis
Dimitrios Sampaziotis
Ioannis A. TsolakisIoannis A. Tsolakis
Ioannis A. Tsolakis
EBElias Bitsanis
Elias Bitsanis
ATApostolos I Tsolakis
Apostolos I Tsolakis
This study aims to compare the effectiveness of two different canine exposure techniques (open and closed) regarding periodontal outcomes, duration of surgical treatment and canine’s eruption, patient’s inconvenience, aesthetics, and orthodontic treatment complications. Electronic database searches of published and unpublished literature were performed. The reference lists of eligible studies were hand searched for additional studies Randomized clinical trials (RCTs), quasi-randomized clinical trials (Q-RCTs) and non-randomized trials of prospective and retrospective design with patients of any age that compared group with palatally impacted canines treated by open exposure to a similar group treated by closed exposure technique were selected. There was not any restriction in language or year of publication. Study selection, data extraction, and risk of bias assessment were performed individually and in duplicate. Search strategy resulted in 159 articles and nine articles were selected for the final analysis. They were three non-randomized trials, one Q-RCT, and two reports of another Q-RCT and three reports of one RCT. The level of reported evidence was high for the RCT and one Q-RCT but poorer for the other trials. Four articles reported periodontal outcomes, three searched the duration of surgical procedure, two the duration of canine eruption, two investigated patient’s inconvenience, two reported on failure rates and two addressed aesthetic outcomes. The results are inconsistent and there is considerable disagreement for the majority of the outcomes among studies. According to existing articles we may conclude that there is no difference between the two techniques regarding the periodontal outcomes and aesthetic appearance. The surgical procedure is shorter in the open exposure group and the amount of postoperative pain during the first day is similar between the open and closed surgical exposure patients. However, these conclusions are based on two single trials with high level of evidence, while the rest of the studies present high risk of bias.