The paper uses Kane’s formalism to study two degrees of freedom (DOF) mechanisms with elastic elements = employed in a wind water pump. This formalism represents an alternative, in our opinion, that is simpler and more economical to Lagrange’s equation, used mainly by researchers in this type of application. In the problems where the finite element method (FEM) is applied, Kane’s equations were not used at all. The automated computation causes it to be reconsidered in the case of mechanical systems with a high DOF. Analyzing the planar transmission mechanism, these equations were applied for the study of an elastic element. An analysis was then made of the results obtained for this type of water pump. The matrices coefficients of the obtained equations were symmetric or skew-symmetric.
1 January 2011 in ANNALS OF THE ORADEA UNIVERSITY. Fascicle of Management and Technological Engineering.
(1) Background: Peripheral nerve repair requires structural guidance and reliable functional assessment, yet current commercial conduits lack internal microarchitecture and do not integrate real-time monitoring capabilities. This study presents an engineering-focused feasibility assessment of a dual system combining a microstructured 3D-printed nerve guidance conduit with a portable neuromuscular monitoring device. (2) Methods: Two conduit variants were digitally designed based on median nerve anatomical dimensions and fabricated using FDM (PLA) for large-scale prototypes and SLA for high-resolution miniaturized models. Structural behavior was evaluated through simplified finite element analysis (FEA) under physiological pressure ranges (1000–5000 Pa). A portable monitoring system incorporating surface EMG electrodes, an AD620 instrumentation amplifier, and an ESP32 microcontroller was assembled and tested non-invasively on a healthy adult volunteer to verify signal acquisition functionality. Results: Both conduit designs were successfully fabricated with accurate reproduction of internal microchannels. FEA indicated negligible deformation (1.41 × 10−11–1.69 × 10−10 mm) and low stress values (0.0129–0.155 N/m2), confirming structural stability under the simplified loading model. The monitoring system recorded stable EMG signals (3200–3500 ADC units), demonstrating correct operation of the acquisition chain during controlled stimulation. (3) Conclusions: This work provides a design-stage engineering feasibility demonstration of an integrated platform combining a microstructured 3D-printed conduit with a portable neuromuscular monitoring device. The study does not include biological validation; prototypes were evaluated solely for geometric and mechanical fidelity; and the monitoring system was tested only for functional signal acquisition. Future work will address biocompatibility, in vitro assays, and in vivo evaluation.