Linhua Zhang

Linhua Zhang


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
JWJunyu Wang
Junyu Wang
YSYongxing SONG
Yongxing SONG
JLJingting Liu
Jingting Liu
LZLinhua Zhang
Linhua Zhang
Electronic expansion valves are widely used in refrigeration systems. However, the two-phase flow-induced noise is often produced during operation. In this paper, the two-phase flow-induced noise characteristics of electronic expansion valves are investigated by means of a combination of numerical calculations and experimental studies. The numerical results show that the noise distribution in the flow field is closely related to the valve opening. As the valve opening increases, the noise in the flow field begins to develop in the downstream region. The experimental results showed a gradual increase in the refrigerant flow rate of the experimental system as the valve opening was increased from 60 to 200 pulses (tested at 10-pulse intervals). The flow-induced noise increases first and then decreases and then increases. With the increase in valve opening, the cavitation phenomenon after valve throttling becomes more and more serious. By processing the noise signal, it is found that the flow-induced noise is distributed in wide frequency. When the valve opening is 60–100 pulse, the noise is mainly concentrated in 10–20 kHz. When the valve opening is 110–150 pulses, the noise concentrated in the high band gradually spreads to the low band. When the valve opening is 160–200 pulses, the noise at low frequency and high frequency increases significantly with the increase in valve opening. After adding a groove structure on the valve core, the noise of the electronic expansion valve decreased by 1.75 dB.

1 October 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
TZTonghe Zhang
Tonghe Zhang
YSYongxing SONG
Yongxing SONG
QLQiang Liu
Qiang Liu
YGYi Ge
Yi Ge
LZLinhua Zhang
Linhua Zhang
JLJingting Liu
Jingting Liu
The rapid and accurate recognition of cavitation in centrifugal pumps has become essential for improving production efficiency and ensuring machinery longevity. To address the limitations of existing methods in terms of applicability, accuracy, and efficiency, a new method based on multi-dimensional feature fusion and convolutional gate recurrent unit (MCGN) was proposed. Experimental monitoring of cavitation of centrifugal pumps was conducted. Five signals at different water temperatures and operating frequencies were collected. Key modulating features were extracted by time-frequency analysis and principal component analysis. The multi-dimensional features are fused by one and two dimensional convolutional neural networks. The cavitation state label was used to label the sample set by cavitation number, net positive suction head, and cavitation evolution images captured by high-speed cameras. Finally, the neural network based on the convolutional gate recurrent unit was used to classify the cavitation state of the centrifugal pump. The experimental results demonstrate that the proposed method achieves recognition accuracies exceeding 98% for vibration signals, noise signals, outlet pressure pulsation signals, and torque signals. Compared with the short-time Fourier transform-autoencoder model, MCGN model can improve the recognition accuracy by 4.03%, computation efficiency by 20%, and loss by 87%. These advances underscore the potential of the method in monitoring and maintenance practices for centrifugal pumps.

31 August 2020 in Processes
Verified
Journal Article
Open access
PDF file
YSYongxing SONG
Yongxing SONG
JLJingting Liu
Jingting Liu
LZLinhua Zhang
Linhua Zhang
Dazhuan WuDazhuan Wu
Dazhuan Wu
Demodulation plays an important role in fault feature extraction for rotating machinery. The fast kurtogram method was proved to be effective for rotating machinery demodulation. However, the demodulation effectiveness of fast kurtogram was poor for multiple fault features extraction under low signal-to-noise ratio. In this paper, an improved method of fast kurtogram, called P-kurtogram, is presented. The proposed method extracted the multiple weak fault features from multiple envelope signals-based principal component analysis. Compared with extracting features from one envelope signal of fast kurtogram, P-kurtogram showed a better demodulation performance for multiple faults. Combined with principal component analysis method, the proposed method also showed a good performance under low signal-to-noise ratio(SNR). By simulation analysis, the P-kurtogram method showed good performance for multiple modulation features extraction and robust performance in demodulation under low SNR. Then, the proposed method was demonstrated by applications of bearing faults detection and propeller detection. The results verified that the P-kurtogram has a better demodulation performance than fast kurtogram for multiple weak fault features extraction, especially under low signal-to-noise ratio. The proposed method provides a reliable basis for multiple weak fault features extraction of rotating machinery.

6 June 2024 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
YSYongxing SONG
Yongxing SONG
TZTonghe Zhang
Tonghe Zhang
QLQiang Liu
Qiang Liu
BGBingxin Ge
Bingxin Ge
JLJingting Liu
Jingting Liu
LZLinhua Zhang
Linhua Zhang

1 May 2021 in Desalination and Water Treatment
Verified
Journal Article
Open access
MZMingyang Zhang
Mingyang Zhang
XLXinzhe Liu
Xinzhe Liu
WLWenda Li
Wenda Li
ZTZhuowei Tan
Zhuowei Tan
QWQian Wang
Qian Wang
LZLinhua Zhang
Linhua Zhang

13 April 2022 in Buildings
Verified
Journal Article
Open access
PDF file
XWXiaolong Wang
Xiaolong Wang
TMTian Mu
Tian Mu
LZLili Zhang
Lili Zhang
WZWenke Zhang
Wenke Zhang
LZLinhua Zhang
Linhua Zhang
The increasing application of floor heating technology promotes the development of floor radiant cooling technology (abbreviated as FRC technology). Many office buildings in northern China try to use FRC technology to cool in summer, but thermal comfort is the key problem restricting the promotion of this technology. The thermal comfort problems of an office room with floor radiant cooling were studied in this paper by the methods of numerical simulation, control variable, and data fitting, and the experimental results were verified in multiple ways. It was found that, for an office room using floor radiant cooling, the effect of the floor surface temperature on thermal comfort was about 16%, while the effect of indoor air temperature was about 84%, and relative humidity had little effect on thermal comfort. A simplified thermal comfort calculation model was proposed, which could be used as an indicator to adjust the floor surface and indoor air temperature, or could be used to calculate the PMV-PPD value. The findings have guiding significance for the design and control of FRC technology.