Frédéric Dehareng

Mr. Frédéric Dehareng

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2011 in Journal of Dairy Science
Verified
Journal Article
Closed access
HSHélène Soyeurt
Hélène Soyeurt
FDFrédéric Dehareng
Frédéric Dehareng
NGNICOLAS GENGLER
NICOLAS GENGLER
SMSinéad McParland
Sinéad McParland
EWE. Wall
E. Wall
PDP. Dardenne
P. Dardenne
Increasing consumer concern exists over the relationship between food composition and human health. Because of the known effects of fatty acids on human health, the development of a quick, inexpensive, and accurate method to directly quantify the fatty acid (FA) composition in milk would be valuable for milk processors to develop a payment system for milk pertinent to their customer requirements and for farmers to adapt their feeding systems and breeding strategies accordingly. The aim of this study was (1) to confirm the ability of mid-infrared spectrometry (MIR) to quantify individual FA content in milk by using an innovative procedure of sampling (i.e., samples were collected from cows belonging to different breeds, different countries, and in different production systems); (2) to compare 6 mathematical methods to develop robust calibration equations for predicting the contents of individual FA in milk; and (3) to test interest in using the FA equations developed in milk as basis to predict FA content in fat without corrections for the slope and the bias of the developed equations. In total, 517 samples selected based on their spectral variability in 3 countries (Belgium, Ireland, and United Kingdom) from various breeds, cows, and production systems were analyzed by gas chromatography (GC). The samples presenting the largest spectral variability were used to calibrate the prediction of FA by MIR. The remaining samples were used to externally validate the 28 FA equations developed. The 6 methods were (1) partial least squares regression (PLS); (2) PLS+repeatability file (REP); (3) first derivative of spectral data+PLS; (4) first derivative+REP+PLS; (5) second derivative of spectral data+PLS; and (6) second derivative+REP+PLS. Methods were compared on the basis of the cross-validation coefficient of determination (R2cv), the ratio of standard deviation of GC values to the standard error of cross-validation (RPD), and the validation coefficient of determination (R2v). The third and fourth methods had, on average, the highest R2cv, RPD, and R2v. The final equations were built using all GC and the best accuracy was observed for the infrared predictions of C4:0, C6:0, C8:0, C10:0, C12:0, C14:0, C16:0, C18:0, C18:1 trans, C18:1 cis-9, C18:1 cis, and for some groups of FA studied in milk (saturated, monounsaturated, unsaturated, short-chain, medium-chain, and long-chain FA). These equations showed R2cv greater than 0.95. With R2cv equal to 0.85, the MIR prediction of polyunsaturated FA could be used to screen the cow population. As previously published, infrared predictions of FA in fat are less accurate than those developed from FA content in milk (g/dL of milk) and no better results were obtained by using milk FA predictions if no corrections for bias and slope based on reference milk samples with known contents of FA were used. These results indicate the usefulness of equations with R2cv greater than 95% in milk payment systems and the usefulness of equations with R2cv greater than 75% for animal breeding purposes.

1 September 2006 in Journal of Dairy Science
Verified
Journal Article
Open access
PDF file
HSHélène Soyeurt
Hélène Soyeurt
PDP. Dardenne
P. Dardenne
FDFrédéric Dehareng
Frédéric Dehareng
GLG. Lognay
G. Lognay
DVD. Veselko
D. Veselko
NGNICOLAS GENGLER
NICOLAS GENGLER
Interest in the fatty acid composition of dairy products is increasing; however, the measurement of fatty acids requires using gas-liquid chromatography. Although this method is suitable, it involves a time-consuming procedure, expensive reagents, and qualified staff. By comparison, the mid-infrared (MIR) spectrometry method could be a good alternative for assessing the fatty acid profile of dairy products. The objective of this study was to explore the calibration of MIR spectrometry for estimating fatty acid concentrations in milk and milk fat. Estimated concentrations in milk fat were less reliable than those for the same fatty acids in milk. Results also showed that when the fatty acid concentrations in milk increased, the efficiency of the infrared analysis method in predicting these values simultaneously increased. Selected prediction equations must have a high cross-validation coefficient of determination, a high ratio of standard error of cross-validation to standard deviation, and good repeatability of chromatographic data. Results from this study showed that the calibration equations predicting 12:0, 14:0, 16:0, 16:1cis-9, 18:1, and saturated and monounsaturated fatty acids in milk could be used. Thus, with its potential for use in regular milk recording, this infrared analysis method offers the possibility of assessing and improving the quality of milk produced. Indeed, it enables the fatty acid composition in milk to be estimated for each cow and the estimates to be used as indicator traits to determine the genetic values of underlying fatty acid concentrations. The knowledge of these genetic values would open up opportunities for animal selection aimed at improving the nutritional quality of cow milk.

1 April 2017 in Journal of Dairy Science
Verified
Journal Article
Open access
ENE. Negussie
E. Negussie
YHY. de Haas
Y. de Haas
FDFrédéric Dehareng
Frédéric Dehareng
RDRichard Dewhurst
Richard Dewhurst
JDJ. Dijkstra
J. Dijkstra
Filippo BiscariniFilippo Biscarini
Filippo Biscarini
Efforts to reduce the carbon footprint of milk production through selection and management of low-emitting cows require accurate and large-scale measurements of methane (CH4) emissions from individual cows. Several techniques have been developed to measure CH4 in a research setting but most are not suitable for large-scale recording on farm. Several groups have explored proxies (i.e., indicators or indirect traits) for CH4; ideally these should be accurate, inexpensive, and amenable to being recorded individually on a large scale. This review (1) systematically describes the biological basis of current potential CH4 proxies for dairy cattle; (2) assesses the accuracy and predictive power of single proxies and determines the added value of combining proxies; (3) provides a critical evaluation of the relative merit of the main proxies in terms of their simplicity, cost, accuracy, invasiveness, and throughput; and (4) discusses their suitability as selection traits. The proxies range from simple and low-cost measurements such as body weight and high-throughput milk mid-infrared spectroscopy (MIR) to more challenging measures such as rumen morphology, rumen metabolites, or microbiome profiling. Proxies based on rumen samples are generally poor to moderately accurate predictors of CH4, and are costly and difficult to measure routinely on-farm. Proxies related to body weight or milk yield and composition, on the other hand, are relatively simple, inexpensive, and high throughput, and are easier to implement in practice. In particular, milk MIR, along with covariates such as lactation stage, are a promising option for prediction of CH4 emission in dairy cows. No single proxy was found to accurately predict CH4, and combinations of 2 or more proxies are likely to be a better solution. Combining proxies can increase the accuracy of predictions by 15 to 35%, mainly because different proxies describe independent sources of variation in CH4 and one proxy can correct for shortcomings in the other(s). The most important applications of CH4 proxies are in dairy cattle management and breeding for lower environmental impact. When breeding for traits of lower environmental impact, single or multiple proxies can be used as indirect criteria for the breeding objective, but care should be taken to avoid unfavorable correlated responses. Finally, although combinations of proxies appear to provide the most accurate estimates of CH4, the greatest limitation today is the lack of robustness in their general applicability. Future efforts should therefore be directed toward developing combinations of proxies that are robust and applicable across diverse production systems and environments.

1 April 2015 in Journal of Dairy Science
Verified
Journal Article
Closed access
CGClement Grelet
Clement Grelet
JPJ.A. Fernández Pierna
J.A. Fernández Pierna
PDP. Dardenne
P. Dardenne
VBV. Baeten
V. Baeten
FDFrédéric Dehareng
Frédéric Dehareng
The goal of this study was to find a procedure to standardize dairy milk mid-infrared spectra from different Fourier transform mid-infrared spectrophotometers (different brands or models) inside a European dairy network to create new farm-management indicators (e.g., fertility, health, feed, environmental impact) based on milk infrared spectra. This step is necessary to create common spectral databases, allowing the building of statistical tools, to be used by all instruments of the network. The method used was piecewise direct standardization (PDS), which matches slave-instrument spectra on master-instrument spectra. To evaluate the possibility of using common equations on different instruments, the PDS method was tested on a set of milk samples measured on each machine, and an equation predicting fat content of milk is applied on all. Regressions were performed between master and slaves fat predictions, before and after PDS. Bias and root mean square error between predictions were decreased after PDS, respectively, from 0.3781 to 0.0000 and from 0.4609 to 0.0156 (g of fat/100mL of milk). The stability over time of these results was confirmed by an application of the coefficients created by PDS 1 mo later on the slave spectra. These preliminary results showed that the PDS method permits a reduction of the inherent spectral variability between instruments, allowing the merging of Fourier transform mid-infrared milk spectra from different instruments into a common database, the creation of new types of dairy farm management indicators, and the use of these common calibrations for all Fourier transform mid-infrared instruments of the European dairy network.

1 June 2016 in Journal of Dairy Science
Verified
Journal Article
Closed access
CGClement Grelet
Clement Grelet
CBC. Bastin
C. Bastin
MGM. Gelé
M. Gelé
JDJ.-B. Davière
J.-B. Davière
MJM. Johan
M. Johan
FDFrédéric Dehareng
Frédéric Dehareng
To manage negative energy balance and ketosis in dairy farms, rapid and cost-effective detection is needed. Among the milk biomarkers that could be useful for this purpose, acetone and β-hydroxybutyrate (BHB) have been proved as molecules of interest regarding ketosis and citrate was recently identified as an early indicator of negative energy balance. Because Fourier transform mid-infrared spectrometry can provide rapid and cost-effective predictions of milk composition, the objective of this study was to evaluate the ability of this technology to predict these biomarkers in milk. Milk samples were collected in commercial and experimental farms in Luxembourg, France, and Germany. Acetone, BHB, and citrate contents were determined by flow injection analysis. Milk mid-infrared spectra were recorded and standardized for all samples. After edits, a total of 548 samples were used in the calibration and validation data sets for acetone, 558 for BHB, and 506 for citrate. Acetone content ranged from 0.020 to 3.355mmol/L with an average of 0.103mmol/L; BHB content ranged from 0.045 to 1.596mmol/L with an average of 0.215mmol/L; and citrate content ranged from 3.88 to 16.12mmol/L with an average of 9.04mmol/L. Acetone and BHB contents were log-transformed and a part of the samples with low values was randomly excluded to approach a normal distribution. The 3 edited data sets were then randomly divided into a calibration data set (3/4 of the samples) and a validation data set (1/4 of the samples). Prediction equations were developed using partial least square regression. The coefficient of determination (R(2)) of cross-validation was 0.73 for acetone, 0.71 for BHB, and 0.90 for citrate with root mean square error of 0.248, 0.109, and 0.70mmol/L, respectively. Finally, the external validation was performed and R(2) obtained were 0.67 for acetone, 0.63 for BHB, and 0.86 for citrate, with respective root mean square error of validation of 0.196, 0.083, and 0.76mmol/L. Although the practical usefulness of the equations developed should be further verified with other field data, results from this study demonstrated the potential of Fourier transform mid-infrared spectrometry to predict citrate content with good accuracy and to supply indicative contents of BHB and acetone in milk, thereby providing rapid and cost-effective tools to manage ketosis and negative energy balance in dairy farms.

1 January 2012 in Animal
Verified
Journal Article
Open access
FDFrédéric Dehareng
Frédéric Dehareng
CDC. Delfosse
C. Delfosse
EFE. Froidmont
E. Froidmont
HSHélène Soyeurt
Hélène Soyeurt
CMC. Martin
C. Martin
PDP. Dardenne
P. Dardenne
This study investigates the feasibility to predict individual methane (CH(4)) emissions from dairy cows using milk mid-infrared (MIR) spectra. To have a large variability of milk composition, two experiments were conducted on 11 lactating Holstein cows (two primiparous and nine multiparous). The first experiment aimed to induce a large variation in CH(4) emission by feeding two different diets: the first one was mainly composed of fresh grass and sugar beet pulp and the second one of maize silage and hay. The second experiment consisted of grass and corn silage with cracked corn, soybean meal and dried pulp. For each milking period, the milk yields were recorded twice daily and a milk sample of 50 ml was collected from each cow and analyzed by MIR spectrometry. Individual CH(4) emissions were measured daily using the sulfur hexafluoride method during a 7-day period. CH(4) daily emissions ranged from 10.2 to 47.1 g CH(4)/kg of milk. The spectral data were transformed to represent an average daily milk spectrum (AMS), which was related to the recorded daily CH(4) data. By assuming a delay before the production of fermentation products in the rumen and their use to produce milk components, five different calculations were used: AMS at days 0, 0.5, 1, 1.5 and 2 compared with the CH(4) measurement. The equations were built using Partial Least Squares regression. From the calculated R(2)(cv), it appears that the accuracy of CH(4) prediction by MIR changed in function of the milking days. In our experimental conditions, the AMS at day 1.5 compared with the measure of CH(4) emissions gave the best results. The R(2) and s.e. of the cross-validation were equal to 0.79 and 5.14 g of CH(4)/kg of milk. The multiple correlation analysis performed in this study showed the existence of a close relationship between milk fatty acid (FA) profile and CH(4) emission at day 1.5. The lower R(2) (R(2) = 0.76) obtained between FA profile and CH(4) emission compared with the one corresponding to the obtained calibration (R(2)(c) = 0.87) shows the interest to apply directly the developed CH(4) equation instead of the use of correlations between FA and CH(4). In conclusion, our preliminary results suggest the feasibility of direct CH(4) prediction from milk MIR spectra. Additional research has the potential to improve the calibrations even further. This alternative method could be useful to predict the individual CH(4) emissions at farm level or at the regional scale and it also could be used to identify low-CH(4)-emitting cows.