Clement Grelet

Dr. Clement Grelet

Walloon Agricultural Research Center (CRA-W), Knowledge and valorization of agricultural products Department, Chaussée de Namur 24, B-5030 Gembloux, Belgium
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2015 in Journal of Dairy Science
Verified
Journal Article
Closed access
CGClement Grelet
Clement Grelet
JPJ.A. Fernández Pierna
J.A. Fernández Pierna
PDP. Dardenne
P. Dardenne
VBV. Baeten
V. Baeten
FDFrédéric Dehareng
Frédéric Dehareng
The goal of this study was to find a procedure to standardize dairy milk mid-infrared spectra from different Fourier transform mid-infrared spectrophotometers (different brands or models) inside a European dairy network to create new farm-management indicators (e.g., fertility, health, feed, environmental impact) based on milk infrared spectra. This step is necessary to create common spectral databases, allowing the building of statistical tools, to be used by all instruments of the network. The method used was piecewise direct standardization (PDS), which matches slave-instrument spectra on master-instrument spectra. To evaluate the possibility of using common equations on different instruments, the PDS method was tested on a set of milk samples measured on each machine, and an equation predicting fat content of milk is applied on all. Regressions were performed between master and slaves fat predictions, before and after PDS. Bias and root mean square error between predictions were decreased after PDS, respectively, from 0.3781 to 0.0000 and from 0.4609 to 0.0156 (g of fat/100mL of milk). The stability over time of these results was confirmed by an application of the coefficients created by PDS 1 mo later on the slave spectra. These preliminary results showed that the PDS method permits a reduction of the inherent spectral variability between instruments, allowing the merging of Fourier transform mid-infrared milk spectra from different instruments into a common database, the creation of new types of dairy farm management indicators, and the use of these common calibrations for all Fourier transform mid-infrared instruments of the European dairy network.

1 June 2016 in Journal of Dairy Science
Verified
Journal Article
Closed access
CGClement Grelet
Clement Grelet
CBC. Bastin
C. Bastin
MGM. Gelé
M. Gelé
JDJ.-B. Davière
J.-B. Davière
MJM. Johan
M. Johan
FDFrédéric Dehareng
Frédéric Dehareng
To manage negative energy balance and ketosis in dairy farms, rapid and cost-effective detection is needed. Among the milk biomarkers that could be useful for this purpose, acetone and β-hydroxybutyrate (BHB) have been proved as molecules of interest regarding ketosis and citrate was recently identified as an early indicator of negative energy balance. Because Fourier transform mid-infrared spectrometry can provide rapid and cost-effective predictions of milk composition, the objective of this study was to evaluate the ability of this technology to predict these biomarkers in milk. Milk samples were collected in commercial and experimental farms in Luxembourg, France, and Germany. Acetone, BHB, and citrate contents were determined by flow injection analysis. Milk mid-infrared spectra were recorded and standardized for all samples. After edits, a total of 548 samples were used in the calibration and validation data sets for acetone, 558 for BHB, and 506 for citrate. Acetone content ranged from 0.020 to 3.355mmol/L with an average of 0.103mmol/L; BHB content ranged from 0.045 to 1.596mmol/L with an average of 0.215mmol/L; and citrate content ranged from 3.88 to 16.12mmol/L with an average of 9.04mmol/L. Acetone and BHB contents were log-transformed and a part of the samples with low values was randomly excluded to approach a normal distribution. The 3 edited data sets were then randomly divided into a calibration data set (3/4 of the samples) and a validation data set (1/4 of the samples). Prediction equations were developed using partial least square regression. The coefficient of determination (R(2)) of cross-validation was 0.73 for acetone, 0.71 for BHB, and 0.90 for citrate with root mean square error of 0.248, 0.109, and 0.70mmol/L, respectively. Finally, the external validation was performed and R(2) obtained were 0.67 for acetone, 0.63 for BHB, and 0.86 for citrate, with respective root mean square error of validation of 0.196, 0.083, and 0.76mmol/L. Although the practical usefulness of the equations developed should be further verified with other field data, results from this study demonstrated the potential of Fourier transform mid-infrared spectrometry to predict citrate content with good accuracy and to supply indicative contents of BHB and acetone in milk, thereby providing rapid and cost-effective tools to manage ketosis and negative energy balance in dairy farms.

1 February 2021 in Methods
Verified
Journal Article
Closed access
CGClement Grelet
Clement Grelet
PDP. Dardenne
P. Dardenne
HSHélène Soyeurt
Hélène Soyeurt
JPJuan Antonio Fernandez Pierna
Juan Antonio Fernandez Pierna
AVAmelie Vanlierde
Amelie Vanlierde
FDFrédéric Dehareng
Frédéric Dehareng

1 May 2016 in Journal of Dairy Science
Verified
Journal Article
Closed access
PDF file
NGNICOLAS GENGLER
NICOLAS GENGLER
HSHélène Soyeurt
Hélène Soyeurt
FDFrédéric Dehareng
Frédéric Dehareng
CBC. Bastin
C. Bastin
FCFrederic Colinet
Frederic Colinet
PDP. Dardenne
P. Dardenne
The challenge of managing and breeding dairy cows is permanently adapting to changing production circumstances under socio-economic constraints. If managing and breeding address different timeframes of action, both need relevant phenotypes that allow for precise monitoring of the status of the cows, and their health, behavior, and well-being as well as their environmental impact and the quality of their products (i.e., milk and subsequently dairy products). Milk composition has been identified as an important source of information because it could reflect, at least partially, all these elements. Major conventional milk components such as fat, protein, urea, and lactose contents are routinely predicted by mid-infrared (MIR) spectrometry and have been widely used for these purposes. But, milk composition is much more complex and other nonconventional milk components, potentially predicted by MIR, might be informative. Such new milk-based phenotypes should be considered given that they are cheap, rapidly obtained, usable on a large scale, robust, and reliable. In a first approach, new phenotypes can be predicted from MIR spectra using techniques based on classical prediction equations. This method was used successfully for many novel traits (e.g., fatty acids, lactoferrin, minerals, milk technological properties, citrate) that can be then useful for management and breeding purposes. An innovation was to consider the longitudinal nature of the relationship between the trait of interest and the MIR spectra (e.g., to predict methane from MIR). By avoiding intermediate steps, prediction errors can be minimized when traits of interest (e.g., methane, energy balance, ketosis) are predicted directly from MIR spectra. In a second approach, research is ongoing to detect and exploit patterns in an innovative manner, by comparing observed with expected MIR spectra directly (e.g., pregnancy). All of these traits can then be used to define best practices, adjust feeding and health management, improve animal welfare, improve milk quality, and mitigate environmental impact. Under the condition that MIR data are available on a large scale, phenotypes for these traits will allow genetic and genomic evaluations. Introduction of novel traits into the breeding objectives will need additional research to clarify socio-economic weights and genetic correlations with other traits of interest.

1 January 2019 in Animal
Verified
Journal Article
Open access
PDF file
CGClement Grelet
Clement Grelet
AVAmelie Vanlierde
Amelie Vanlierde
Miel HostensMiel Hostens
Miel Hostens
LFLeslie Foldager
Leslie Foldager
MSMazdak Salavati
Mazdak Salavati
FDFrédéric Dehareng
Frédéric Dehareng
Unbalanced metabolic status in the weeks after calving predisposes dairy cows to metabolic and infectious diseases. Blood glucose, IGF-I, non-esterified fatty acids (NEFA) and β-hydroxybutyrate (BHB) are used as indicators of the metabolic status of cows. This work aims to (1) evaluate the potential of milk mid-IR spectra to predict these blood components individually and (2) to evaluate the possibility of predicting the metabolic status of cows based on the clustering of these blood components. Blood samples were collected from 241 Holstein cows on six experimental farms, at days 14 and 35 after calving. Blood samples were analyzed by reference analysis and metabolic status was defined by k-means clustering (k=3) based on the four blood components. Milk mid-IR analyses were undertaken on different instruments and the spectra were harmonized into a common standardized format. Quantitative models predicting blood components were developed using partial least squares regression and discriminant models aiming to differentiate the metabolic status were developed with partial least squares discriminant analysis. Cross-validations were performed for both quantitative and discriminant models using four subsets randomly constituted. Blood glucose, IGF-I, NEFA and BHB were predicted with respective R 2 of calibration of 0.55, 0.69, 0.49 and 0.77, and R 2 of cross-validation of 0.44, 0.61, 0.39 and 0.70. Although these models were not able to provide precise quantitative values, they allow for screening of individual milk samples for high or low values. The clustering methodology led to the sharing out of the data set into three groups of cows representing healthy, moderately impacted and imbalanced metabolic status. The discriminant models allow to fairly classify the three groups, with a global percentage of correct classification up to 74%. When discriminating the cows with imbalanced metabolic status from cows with healthy and moderately impacted metabolic status, the models were able to distinguish imbalanced group with a global percentage of correct classification up to 92%. The performances were satisfactory considering the variables are not present in milk, and consequently predicted indirectly. This work showed the potential of milk mid-IR analysis to provide new metabolic status indicators based on individual blood components or a combination of these variables into a global status. Models have been developed within a standardized spectral format, and although robustness should preferably be improved with additional data integrating different geographic regions, diets and breeds, they constitute rapid, cost-effective and large-scale tools for management and breeding of dairy cows.

1 October 2017 in Journal of Dairy Science
Verified
Journal Article
Closed access
CGClement Grelet
Clement Grelet
JPJ. A. Fernández Pierna
J. A. Fernández Pierna
PDP. Dardenne
P. Dardenne
HSHélène Soyeurt
Hélène Soyeurt
AVA. Vanlierde
A. Vanlierde
FDFrédéric Dehareng
Frédéric Dehareng
An increasing number of models are being developed to provide information from milk Fourier transform mid-infrared (FT-MIR) spectra on fine milk composition, technological properties of milk, or even cows' physiological status. In this context, and to take advantage of these existing models, the purpose of this work was to evaluate whether a spectral standardization method can enable the use of multiple equations within a network of different FT-MIR spectrometers. The piecewise direct standardization method was used, matching "slave" instruments to a common reference, the "master." The effect of standardization on network reproducibility was assessed on 66 instruments from 3 different brands by comparing the spectral variability of the slaves and the master with and without standardization. With standardization, the global Mahalanobis distance from the slave spectra to the master spectra was reduced on average from 2,655.9 to 14.3, representing a significant reduction of noninformative spectral variability. The transfer of models from instrument to instrument was tested using 3 FT-MIR models predicting (1) the quantity of daily methane emitted by dairy cows, (2) the concentration of polyunsaturated fatty acids in milk, and (3) the fresh cheese yield. The differences, in terms of root mean squared error, between master predictions and slave predictions were reduced after standardization on average from 103 to 17 g/d, from 0.0315 to 0.0045 g/100 mL of milk, and from 2.55 to 0.49 g of curd/100 g of milk, respectively. For all the models, standard deviations of predictions among all the instruments were also reduced by 5.11 times for methane, 5.01 times for polyunsaturated fatty acids, and 7.05 times for fresh cheese yield, showing an improvement of prediction reproducibility within the network. Regarding the results obtained, spectral standardization allows the transfer and use of multiple models on all instruments as well as the improvement of spectral and prediction reproducibility within the network. The method makes the models universal, thereby offering opportunities for data exchange and the creation and use of common robust models at an international level to provide more information to the dairy sector from direct analysis of milk.