Katsuhiko Kato

Prof. Dr. Katsuhiko Kato

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013 in Clinical Nuclear Medicine
Verified
Journal Article
Closed access
KKKatsuhiko Kato
Katsuhiko Kato
TNTakashi Nihashi
Takashi Nihashi
MIMitsuru Ikeda
Mitsuru Ikeda
SAShinji Rt Abe
Shinji Rt Abe
SIShingo Iwano
Shingo Iwano
SNShinji Naganawa
Shinji Naganawa
Objective Differentiation between metastasis-free pancreatic cancer and mass-forming pancreatitis is important to avoid unnecessary operative procedures. This study was aimed at evaluating the efficacy of PET/CT with 18F-FDG (FDG PET/CT) for the differential diagnosis between them. Patients and Methods FDG-PET/CT was performed in 47 study patients with pancreatic masses and without any detectable metastases, 33 of which cases were finally diagnosed as pancreatic cancer and the other 14 as pancreatitis, and the corresponding imaging data were evaluated retrospectively. The maximal SUV (SUVmax) within the masses were determined at 1 hour and mostly at 2 hours after intravenous injection of FDG. Results SUVmax at 1 hour in pancreatic cancer was significantly higher than that in mass-forming pancreatitis, and the change in SUVmax from 1- to 2-hour time points was more consistent with pancreatic cancer than with mass-forming pancreatitis. However, there remained considerable overlapping between the SUVmax values of both diseases except either at the higher range for pancreatic cancer (> 7.7 at 1 hour or > 9.98 at 2 hours) or at the lower range for mass-forming pancreatitis (<3.37 at 1 hour or <3.53 at 2 hours). No obvious difference was found in the FDG uptake patterns of the mass areas between both diseases. Conclusions Differentiation between metastasis-free pancreatic cancer and mass-forming pancreatitis is difficult by FDG-PET/CT due to considerable overlapping between the SUVmax values of the two diseases, although the differential diagnosis may be possible either at the higher range of SUVmax (> 7.7 at 1 hour or > 9.98 at 2 hours) for pancreatic cancer or at the lower range of SUVmax (<3.37 at 1 hour or <3.53 at 2 hours) for mass-forming pancreatitis.

17 April 2018 in Annals of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
HIHiroaki Ishiguchi
Hiroaki Ishiguchi
SIShinji Ito
Shinji Ito
KKKatsuhiko Kato
Katsuhiko Kato
YSYusuke Sakurai
Yusuke Sakurai
HKHisashi Kawai
Hisashi Kawai
SNShinji Naganawa
Shinji Naganawa
Recent many studies have shown that whole body “diffusion-weighted imaging with background body signal suppression” (DWIBS) seems a beneficial tool having higher tumor detection sensitivity without ionizing radiation exposure for pediatric tumors. In this study, we evaluated the diagnostic performance of whole body DWIBS and 18F-FDG PET/CT for detecting lymph node and bone metastases in pediatric patients with neuroblastoma.

1 February 2014 in British Journal of Radiology
Verified
Journal Article
Closed access
NONaotoshi Ota
Naotoshi Ota
KKKatsuhiko Kato
Katsuhiko Kato
SIShingo Iwano
Shingo Iwano
SIShinji Ito
Shinji Ito
SAShinji Abe
Shinji Abe
SNShinji Naganawa
Shinji Naganawa
We compared the efficacies of ¹⁸F-fluoride positron emission tomography (¹⁸F-fluoride PET)/CT, ¹⁸F-fludeoxyglucose PET (¹⁸F-FDG PET)/CT, and ⁹⁹mTc bone scintigraphy [planar and single photon emission CT (SPECT)] for the detection of bone metastases in patients with differentiated thyroid carcinoma (DTC). We examined 11 patients (8 females and 3 males; mean age 6 standard deviation, 61.968.7 years) with DTC who had been suspected of having bone metastases after total thyroidectomy and were hospitalized to be given ¹³¹I therapy. Bone metastases were verified either when positive findings were obtained on both ¹³¹I scintigraphy and CT or when MRI findings were positive if MRI was performed. Metastases were confirmed in 24 (13.6%) of 176 bone segments in 9 (81.8%) of the 11 patients. The sensitivities of ¹⁸F-fluoride PET/CT and ⁹⁹mTc bone scintigraphy (SPECT) were significantly higher than those of ¹⁸F-FDG PET/CT and ⁹⁹mTc bone scintigraphy (planar) (p,0.05). The accuracies of ¹⁸F-fluoride PET/CT and mTc bone scintigraphy (SPECT) were significantly higher than that of ⁹⁹mTc bone scintigraphy (planar) (p,0.05). The sensitivity and accuracy of ¹⁸F-fluoride PET/CT for the detection of bone metastases of DTC are significantly higher than those of ⁹⁹mTc bone scintigraphy (planar). However, the sensitivity and accuracy of ⁹⁹mTc bone scintigraphy (planar) are improved near to those of ¹⁸F-fluoride PET/CT when SPECT is added to a planar scan. The sensitivity of ¹⁸F-FDG PET/CT is significantly lower than that of 18F-fluoride PET/CT or ⁹⁹mTc bone scintigraphy (SPECT).

8 August 2014 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
NSNaoto Sassa
Naoto Sassa
KKKatsuhiko Kato
Katsuhiko Kato
SAShinji Abe
Shinji Abe
SIShingo Iwano
Shingo Iwano
SIShinji Ito
Shinji Ito
SNShinji Naganawa
Shinji Naganawa
We conducted a pilot study to prospectively evaluate the efficacy of PET/CT with 11C-choline (choline PET/CT) for primary diagnosis and staging of urothelial carcinoma of the upper urinary tract (UUT-UC).

22 April 2014 in Cancer Imaging
Verified
Journal Article
Open access
SIShingo Iwano
Shingo Iwano
MKMariko Kishimoto
Mariko Kishimoto
SIShinji Ito
Shinji Ito
KKKatsuhiko Kato
Katsuhiko Kato
RIRintaro Ito
Rintaro Ito
SNShinji Naganawa
Shinji Naganawa
The ratio of the maximum diameter of consolidation to the maximum tumor diameter (C/T ratio) on thin-section computed tomography (TSCT) and the maximum standardized uptake value (SUVmax) on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) are often used as preoperative independent variables to evaluate the invasiveness of lung adenocarcinoma. We investigated the associations between these independent variables and pathologic invasiveness in pulmonary adenocarcinomas. We selected patients with peripheral lung adenocarcinomas, definitively diagnosed by surgical resection, with diameters of ≤ 30 mm over a 4-year period ending in December 2010. The association between 3 independent variables (tumor size, SUVmax, and C/T ratio) and pathologic prognostic factors was evaluated using logistic analysis. We evaluated a total of 163 primary lung adenocarcinomas in 148 patients (93 males and 55 females; age range: 34 to 84 years). Using multivariate logistic regression analysis, SUVmax and the C/T ratio were significantly associated with tumor invasiveness (odds ratio [OR] = 1.227; p = 0.025 and OR = 1.019; p = 0.008, respectively). Tumor size was not associated with invasiveness (OR = 1.003; p = 0.925). For solid type adenocarcinomas, only SUVmax was significantly associated with invasiveness (OR = 1.558; p = 0.003). For subsolid type adenocarcinomas, only the C/T ratio was significantly associated with invasiveness (OR = 1.030; p = 0.009). Both the C/T ratio and the SUVmax are significantly correlated with pathologic invasiveness in patients with small lung adenocarcinomas, while there was a difference between the 2 evaluations. Solid type adenocarcinomas with SUVmax values of ≥ 4.4 and subsolid type adenocarcinomas with C/T ratio ≥ 53% were so highly invasive.

1 January 2002 in Tetsu-to-Hagane
Verified
Journal Article
Open access
PDF file
KMKen-Ichiro Miyamoto
Ken-Ichiro Miyamoto
KKKatsuhiko Kato
Katsuhiko Kato
TYToshitaka Yuki
Toshitaka Yuki
The experiments were performed using a small-scale furnace in order to improve the reduction rate of chromium oxide in Cr2O3 containing slag by carbon in steel. As a result of the investigation of the experiments by SOLGASMIX, the following points were clarified: 1) The reduction rate of chromium oxide in slag was improved by lowering the basicity of the slag or by adding Al2O3 or CaF2. This improvement was caused by the increase of liquid phase fraction of the slag. 2) The liquid fraction of the slag was related to the increase of the mass transfer coefficient and/or the effective reaction area of reaction. 3) The dissolution of MgO was accelerated greatly by lowering the basicity or by adding CaF2. This phenomenon was caused by the increase of MgO solubility in the slag. 4) The optimum composition of slag is (Al2O3)=15% and CaO/SiO2=2.5 from the viewpoint of the compatibility of the improvement of reduction rate of chromium oxide and the prevention of the dissolution of the refractories.