Yanbin Shi

Dr. Yanbin Shi


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Jian DuJian Du
Jian Du
Li WangLi Wang
Li Wang
YSYanbin Shi
Yanbin Shi
FZFeng Zhang
Feng Zhang
SHShiheng Hu
Shiheng Hu
JCJun Chen
Jun Chen
The CNT-PDMS composite has been widely adopted in flexible devices due to its high elasticity, piezoresistivity, and biocompatibility. In a wide range of applications, CNT-PDMS composite sensors were used for resistive strain measurement. Accordingly, the percolation threshold 2%~4% of the CNT weight ratio in the CNT-PDMS composite was commonly selected, which is expected to achieve the optimized piezoresistive sensitivity. However, the linear range around the percolation threshold weight ratio (2%~4%) limits its application in a stable output of large strain (>20%). Therefore, comprehensive understanding of the electromechanical, mechanical, and electrical properties for the CNT-PDMS composite with different CNT weight ratios was expected. In this paper, a systematic study was conducted on the piezoresistivity, Young’s modulus, conductivity, impedance, and the cross-section morphology of different CNT weight ratios (1 to 10 wt%) of the CNT-PDMS composite material. It was experimentally observed that the piezo-resistive sensitivity of CNT-PDMS negatively correlated with the increase in the CNT weight ratio. However, the electrical conductivity, Young’s modulus, tensile strength, and the linear range of piezoresistive response of the CNT-PDMS composite positively correlated with the increase in CNT weight ratio. Furthermore, the mechanism of these phenomena was analyzed through the cross-section morphology of the CNT-PDMS composite material by using SEM imaging. From this analysis, a guideline was proposed for large strain (40%) measurement applications (e.g., motion monitoring of the human body of the finger, arm, foot, etc.), the CNT weight ratio 8 wt% was suggested to achieve the best piezoresistive sensitivity in the linear range.

1 September 2018 in Journal of Controlled Release
Verified
Journal Article
Closed access
ZGZili Gu
Zili Gu
QWQingjie Wang
Qingjie Wang
YSYanbin Shi
Yanbin Shi
YHYi Huang
Yi Huang
JZJing Zhang
Jing Zhang
GLGui-mei Lin
Gui-mei Lin

1 November 2019 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
XFXianglei Fu
Xianglei Fu
YSYanbin Shi
Yanbin Shi
HWHui Wang
Hui Wang
XZXiaogang Zhao
Xiaogang Zhao
QSQifeng Sun
Qifeng Sun
GLGui-mei Lin
Gui-mei Lin
Purpose: Thymosin β-4(Tβ-4) is a macromolecular protein drug with potential for drug development in wound repair but is limited by the shortcomings of macromolecular protein, such as large volumes, poor membrane permeability, and unstable physicochemical characteristics. Ethosomes could enhance cell membrane fluidity and reduce epidermal membrane density to make macromolecular drugs through the stratum corneum into the deeper layers of the skin easily. Herein, we developed and characterized a novel transdermal delivery vehicle to load macromolecular protein peptides and use Tβ-4 as a model drug wrapped into ethosomes. Methods: We used the orthogonal method to optimize the formulation of the ethosome preparation prepared by the ethonal infusion method. Ethosomal gels were characterized by using different analytical methods. Transdermal release rate in vitro have been demonstrated in Franz diffusion cells and the efficacy of drug-loaded nanocarriers in vivo was investigated in a mouse model. Results: Optimized Tβ-4 ethosomal gels have good physicochemical properties. The drug amounts of the cumulative release in the ethosomal gel within 5 hours were 1.67 times that of the T-β4 gel in vitro release study, and the wound healing time of ethosomal gel group was only half of the T-β4 gel group in vivo pharmacokinetic study. Compared with the free drug group, the ethosome preparation not only promotes the percutaneous absorption process of the macromolecular protein drugs but also shortened wound recovery time. Conclusion: Hence, we provide a possible good design for ethosomal gel system that can load macromolecular protein peptide drugs to achieve transdermal drug administration, promoting the percutaneous absorption of the drug and improving the effect.


10 November 2023 in Advanced Functional Materials
Verified
Journal Article
Closed access
DKDeyin Kong
Deyin Kong
QWQing Wang
Qing Wang
JHJiangeng Huang
Jiangeng Huang
ZZZhihui Zhang
Zhihui Zhang
XWXiebin Wang
Xiebin Wang
YSYanbin Shi
Yanbin Shi

1 September 2020 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
YGYan Gao
Yan Gao
YSYanbin Shi
Yanbin Shi
MFMengguang Fu
Mengguang Fu
YFYihua Feng
Yihua Feng
GLGuimei Lin
Guimei Lin
BJBo Jiang
Bo Jiang