Li Wang

Prof. Li Wang

Professor of Qilu University of Technology

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Jian DuJian Du
Jian Du
Li WangLi Wang
Li Wang
YSYanbin Shi
Yanbin Shi
FZFeng Zhang
Feng Zhang
SHShiheng Hu
Shiheng Hu
JCJun Chen
Jun Chen
The CNT-PDMS composite has been widely adopted in flexible devices due to its high elasticity, piezoresistivity, and biocompatibility. In a wide range of applications, CNT-PDMS composite sensors were used for resistive strain measurement. Accordingly, the percolation threshold 2%~4% of the CNT weight ratio in the CNT-PDMS composite was commonly selected, which is expected to achieve the optimized piezoresistive sensitivity. However, the linear range around the percolation threshold weight ratio (2%~4%) limits its application in a stable output of large strain (>20%). Therefore, comprehensive understanding of the electromechanical, mechanical, and electrical properties for the CNT-PDMS composite with different CNT weight ratios was expected. In this paper, a systematic study was conducted on the piezoresistivity, Young’s modulus, conductivity, impedance, and the cross-section morphology of different CNT weight ratios (1 to 10 wt%) of the CNT-PDMS composite material. It was experimentally observed that the piezo-resistive sensitivity of CNT-PDMS negatively correlated with the increase in the CNT weight ratio. However, the electrical conductivity, Young’s modulus, tensile strength, and the linear range of piezoresistive response of the CNT-PDMS composite positively correlated with the increase in CNT weight ratio. Furthermore, the mechanism of these phenomena was analyzed through the cross-section morphology of the CNT-PDMS composite material by using SEM imaging. From this analysis, a guideline was proposed for large strain (40%) measurement applications (e.g., motion monitoring of the human body of the finger, arm, foot, etc.), the CNT weight ratio 8 wt% was suggested to achieve the best piezoresistive sensitivity in the linear range.

28 February 2022 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
WDWenkun Dou
Wenkun Dou
MMManpreet Malhi
Manpreet Malhi
QZQili Zhao
Qili Zhao
Li WangLi Wang
Li Wang
ZHZongjie Huang
Zongjie Huang
YSYu Sun
Yu Sun
Emerging heart-on-a-chip platforms are promising approaches to establish cardiac cell/tissue models in vitro for research on cardiac physiology, disease modeling and drug cardiotoxicity as well as for therapeutic discovery. Challenges still exist in obtaining the complete capability of in situ sensing to fully evaluate the complex functional properties of cardiac cell/tissue models. Changes to contractile strength (contractility) and beating regularity (rhythm) are particularly important to generate accurate, predictive models. Developing new platforms and technologies to assess the contractile functions of in vitro cardiac models is essential to provide information on cell/tissue physiologies, drug-induced inotropic responses, and the mechanisms of cardiac diseases. In this review, we discuss recent advances in biosensing platforms for the measurement of contractile functions of in vitro cardiac models, including single cardiomyocytes, 2D monolayers of cardiomyocytes, and 3D cardiac tissues. The characteristics and performance of current platforms are reviewed in terms of sensing principles, measured parameters, performance, cell sources, cell/tissue model configurations, advantages, and limitations. In addition, we highlight applications of these platforms and relevant discoveries in fundamental investigations, drug testing, and disease modeling. Furthermore, challenges and future outlooks of heart-on-a-chip platforms for in vitro measurement of cardiac functional properties are discussed.

22 July 2022 in ACS Nano
Verified
Journal Article
Closed access
Li WangLi Wang
Li Wang
XXXingyuan Xu
Xingyuan Xu
JCJun Chen
Jun Chen
WSWeiguang Su
Weiguang Su
FZFeng Zhang
Feng Zhang
YSYu Sun
Yu Sun

6 June 2024 in ACS Sensors
Verified
Journal Article
Closed access
WZWeilong Zhao
Weilong Zhao
WZWenhong Zhang
Wenhong Zhang
JCJun Chen
Jun Chen
HLHuimin Li
Huimin Li
LHLin Han
Lin Han
Li WangLi Wang
Li Wang

4 August 2021 in The Analyst
Verified
Journal Article
Closed access
PDF file
ZYZhipeng Yuan
Zhipeng Yuan
Li WangLi Wang
Li Wang
JCJun Chen
Jun Chen
WSWeiguang Su
Weiguang Su
ALAnqing Li
Anqing Li
XZXiangxiang Zhou
Xiangxiang Zhou
Here, we organize all the pictures that appear in the text separately.

1 January 2023 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
Li WangLi Wang
Li Wang
JHJunlei Han
Junlei Han
WSWeiguang Su
Weiguang Su
ALAnqing Li
Anqing Li
WZWenxian Zhang
Wenxian Zhang
JCJun Chen
Jun Chen
Animal models and static cultures of intestinal epithelial cells are commonly used platforms for exploring mercury ion (Hg(II)) transport. However, they cannot reliably simulate the human intestinal microenvironment and monitor cellular physiology in situ; thus, the mechanism of Hg(II) transport in the human intestine is still unclear. Here, a gut-on-a-chip integrated with transepithelial electrical resistance (TEER) sensors and electrochemical sensors is proposed for dynamically simulating the formation of the physical intestinal barrier and monitoring the transport and absorption of Hg(II) in situ. The cellular microenvironment was recreated by applying fluid shear stress (0.02 dyne/cm2) and cyclic mechanical strain (1%, 0.15 Hz). Hg(II) absorption and physical damage to cells were simultaneously monitored by electrochemical and TEER sensors when intestinal epithelial cells were exposed to different concentrations of Hg(II) mixed in culture medium. Hg(II) absorption increased by 23.59% when tensile strain increased from 1% to 5%, and the corresponding expression of Piezo1 and DMT1 on the cell surface was upregulated.