Gerd Reis

Dr. Gerd Reis

German Research Centre for Artificial Intelligence (DFKI GmbH), Trippstadter Str. 122, 67663 Kaiserslautern, Germany

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2022 in ACM Computing Surveys
Verified
Journal Article
Open access
ASAlexander Schäfer
Alexander Schäfer
Gerd ReisGerd Reis
Gerd Reis
Didier StrickerDidier Stricker
Didier Stricker
Remote collaboration systems have become increasingly important in today’s society, especially during times when physical distancing is advised. Industry, research, and individuals face the challenging task of collaborating and networking over long distances. While video and teleconferencing are already widespread, collaboration systems in augmented, virtual, and mixed reality are still a niche technology. We provide an overview of recent developments of synchronous remote collaboration systems and create a taxonomy by dividing them into three main components that form such systems: Environment , Avatars , and Interaction . A thorough overview of existing systems is given, categorising their main contributions to help researchers working in different fields by providing concise information about specific topics such as avatars, virtual environment, visualisation styles, and interaction. The focus of this work is clearly on synchronised collaboration from a distance. A total of 87 unique systems for remote collaboration are discussed, including more than 100 publications and 25 commercial systems.

18 March 2021 in Electronics
Verified
Journal Article
Open access
PDF file
ASAlexander Schäfer
Alexander Schäfer
Gerd ReisGerd Reis
Gerd Reis
Didier StrickerDidier Stricker
Didier Stricker
Virtual Reality (VR) technology offers users the possibility to immerse and freely navigate through virtual worlds. An important component for achieving a high degree of immersion in VR is locomotion. Often discussed in the literature, a natural and effective way of controlling locomotion is still a general problem which needs to be solved. Recently, VR headset manufacturers have been integrating more sensors, allowing hand or eye tracking without any additional required equipment. This enables a wide range of application scenarios with natural freehand interaction techniques where no additional hardware is required. This paper focuses on techniques to control teleportation-based locomotion with hand gestures, where users are able to move around in VR using their hands only. With the help of a comprehensive study involving 21 participants, four different techniques are evaluated. The effectiveness and efficiency as well as user preferences of the presented techniques are determined. Two two-handed and two one-handed techniques are evaluated, revealing that it is possible to move comfortable and effectively through virtual worlds with a single hand only.

3 September 2022
Verified
Book Chapter
Open access
PDF file
ASAlexander Schäfer
Alexander Schäfer
Gerd ReisGerd Reis
Gerd Reis
Didier StrickerDidier Stricker
Didier Stricker
Moving around in a virtual world is one of the essential interactions for Virtual Reality (VR) applications. The current standard for moving in VR is using a controller. Recently, VR Head Mounted Displays integrate new input modalities such as hand tracking which allows the investigation of different techniques to move in VR. This work explores different techniques for bare-handed locomotion since it could offer a promising alternative to existing freehand techniques. The presented techniques enable continuous movement through an immersive virtual environment. The proposed techniques are compared to each other in terms of efficiency, usability, perceived workload, and user preference.

16 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MKMhd Rashed Al Koutayni
Mhd Rashed Al Koutayni
VRVladimir Rybalkin
Vladimir Rybalkin
JMJAMEEL MALIK
JAMEEL MALIK
AEAhmed Elhayek
Ahmed Elhayek
CWChristian Weis
Christian Weis
Didier StrickerDidier Stricker
Didier Stricker
The estimation of human hand pose has become the basis for many vital applications where the user depends mainly on the hand pose as a system input. Virtual reality (VR) headset, shadow dexterous hand and in-air signature verification are a few examples of applications that require to track the hand movements in real-time. The state-of-the-art 3D hand pose estimation methods are based on the Convolutional Neural Network (CNN). These methods are implemented on Graphics Processing Units (GPUs) mainly due to their extensive computational requirements. However, GPUs are not suitable for the practical application scenarios, where the low power consumption is crucial. Furthermore, the difficulty of embedding a bulky GPU into a small device prevents the portability of such applications on mobile devices. The goal of this work is to provide an energy efficient solution for an existing depth camera based hand pose estimation algorithm. First, we compress the deep neural network model by applying the dynamic quantization techniques on different layers to achieve maximum compression without compromising accuracy. Afterwards, we design a custom hardware architecture. For our device we selected the FPGA as a target platform because FPGAs provide high energy efficiency and can be integrated in portable devices. Our solution implemented on Xilinx UltraScale+ MPSoC FPGA is 4.2× faster and 577.3× more energy efficient than the original implementation of the hand pose estimation algorithm on NVIDIA GeForce GTX 1070.

11 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ASAlexander Schäfer
Alexander Schäfer
Gerd ReisGerd Reis
Gerd Reis
Didier StrickerDidier Stricker
Didier Stricker
Natural user interfaces based on hand gestures are becoming increasingly popular. The need for expensive hardware left a wide range of interaction possibilities that hand tracking enables largely unexplored. Recently, hand tracking has been built into inexpensive and widely available hardware, allowing more and more people access to this technology. This work provides researchers and users with a simple yet effective way to implement various one-handed gestures to enable deeper exploration of gesture-based interactions and interfaces. To this end, this work provides a framework for design, prototyping, testing, and implementation of one-handed gestures. The proposed framework was implemented with two main goals: First, it should be able to recognize any one-handed gesture. Secondly, the design and implementation of gestures should be as simple as performing the gesture and pressing a button to record it. The contribution of this paper is a simple yet unique way to record and recognize static and dynamic one-handed gestures. A static gesture can be captured with a template matching approach, while dynamic gestures use previously captured spatial information. The presented approach was evaluated in a user study with 33 participants and the implementable gestures received high accuracy and user acceptance.

25 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Gerd ReisGerd Reis
Gerd Reis
XTXiaoying Tan
Xiaoying Tan
LKLea Kraft
Lea Kraft
MYMehmet Yilmaz
Mehmet Yilmaz
DSDominik Schoeb
Dominik Schoeb
AMArkadiusz Miernik
Arkadiusz Miernik
We have developed a sensor for monitoring the hemoglobin (Hb) concentration in the effluent of a continuous bladder irrigation. The Hb concentration measurement is based on light absorption within a fixed measuring distance. The light frequency used is selected so that both arterial and venous Hb are equally detected. The sensor allows the measurement of the Hb concentration up to a maximum value of 3.2 g/dL (equivalent to ≈20% blood concentration). Since bubble formation in the outflow tract cannot be avoided with current irrigation systems, a neural network is implemented that can robustly detect air bubbles within the measurement section. The network considers both optical and temporal features and is able to effectively safeguard the measurement process. The sensor supports the use of different irrigants (salt and electrolyte-free solutions) as well as measurement through glass shielding. The sensor can be used in a non-invasive way with current irrigation systems. The sensor is positively tested in a clinical study.