In recent years, computational fluid dynamics (CFD) has been extensively used in biomedical research on heart diseases due to its non-invasiveness and relative ease of use in predicting flow patterns inside the cardiovascular system. In this study, a modeling approach involving CFD simulations was employed to study hemodynamics inside the left ventricle (LV) of a human heart affected by a mitral paravalvular leak (PVL). A simplified LV geometry with four PVL variants that varied in shape and size was studied. Predicted blood flow parameters, mainly velocity and shear stress distributions, were used as indicators of how presence of PVLs correlates with risk and severity of hemolysis. The calculations performed in the study showed a high risk of hemolysis in all analyzed cases, with the maximum shear stress values considerably exceeding the safe level of 300 Pa. Results of our study indicated that there was no simple relationship between PVL geometry and the risk of hemolysis. Two factors that potentially played a role in hemolysis severity, namely erythrocyte exposure time and the volume of fluid in which shear stress exceeded a critical value, were not directly proportional to any of the characteristic geometrical parameters (shape, diameters, circumference, area, volume) of the PVL channel. Potential limitations of the proposed simplified approach of flow analysis are discussed, and possible modifications to increase the accuracy and plausibility of the results are presented.
Paravalvular leaks (PVLs) may lead to hemolysis. In vitro shear stress forces above 300 Pa cause erythrocyte destruction. PVL channel dimensions may determine magnitude of shear stress forces that affect erythrocytes; however, this has not been tested. It remains unclear how different properties of PVL channels contribute to presence of hemolysis. A model of a left ventricle was created based on data from computer tomography with Slicer software PVLs of various shapes and sizes were introduced. Blood flow was simulated using ANSYS Fluent software. The following variables were examined: wall shear stress, shear stress in fluid, volume of PVL channel with shear stress exceeding 300 Pa, and duration of exposure of erythrocytes to shear stress values above 300 Pa. In all models, shear stress forces exceeded 300 Pa. Shear stress increased with blood flow rates and cross-sectional areas of any PVL. There was no linear relationship between cross-sectional area of a PVL and volume of a PVL channel with shear stress > 300 Pa. Blood flow through mitral PVLs is associated with shear stress above 300 Pa. Cross-sectional area of a PVL does not correlate with volume of a PVL channel with shear stress > 300 Pa and duration of exposure of erythrocytes to shear stress > 300 Pa.
1 June 2020 in Chemical Engineering Research and Design
Background: Shear forces affecting erythrocytes in PVL channels can be calculated with computational fluid dynamics (CFD). The presence of PVLs is always associated with some degree of hemolysis in a simplified model of the left ventricle (LV); however, data from real-life examples is lacking. Methods: Blood flow through PVL channels was assessed in two variants. Firstly, a PVL channel, extracted from cardiac computed tomography (CCT), was placed in a simplified model of the LV. Secondly, a real-life model of the LV was created based on CCT data from a subject with a PVL. The following variables were assessed: wall shear stress (τw) shear stress in fluid (τ), volume of PVL channel with wall shear stress above 300 Pa (V300), duration of exposure of erythrocytes to shear stress above 300 Pa (Vt300) and compared with lactate dehydrogenase (LDH) activity levels. Results: τw and τ were higher in the simplified model. V300 and Vt300 were almost identical in both models. Conclusions: Parameters that describe blood flow through PVL channels can be reliably assessed in a simplified model. LDH levels in subjects with PVLs may be related to V300 and Vt300. Length and location of PVL channels may contribute to a risk of hemolysis in mitral PVLs.
Improvements in the diagnosis and treatment of cardiovascular diseases facilitate a better understanding of the ongoing process. The study of biomedical fluid dynamics using non-intrusive visualizing methods on a micro-scale has become possible using a proper 3D printing process. The computed tomography scan of a patient with atherosclerosis was processed, and a 3D-printed artery with an inlet diameter of 4.2 mm was developed and measured using three different constant flow rates. To mimic blood, a solution of glycerin and water was used. The procedure to obtain a proper 3D-printed model using low-force stereolithography technology with high-quality optical access usable for PIV was described and discussed. The paper presents the results of PIV as multi-stitched, color-coded vector maps from the axis cross section along the whole 3D-printed model. The obtained data allowed a resolution of 100 × 100 µm per single vector to be achieved. Furthermore, the results of the stitched 16 base images of the artery and the 3D-printed model prepared were included. The results of this study show that 3D prints allow for the creation of the desired geometry and can be used to investigate severe pathologies of the human circulatory system. The strengths and weaknesses of this methodology were discussed and compared to other techniques used to obtain transparent objects.
1 July 2017 in Chemical Engineering Research and Design