Improvements in the diagnosis and treatment of cardiovascular diseases facilitate a better understanding of the ongoing process. The study of biomedical fluid dynamics using non-intrusive visualizing methods on a micro-scale has become possible using a proper 3D printing process. The computed tomography scan of a patient with atherosclerosis was processed, and a 3D-printed artery with an inlet diameter of 4.2 mm was developed and measured using three different constant flow rates. To mimic blood, a solution of glycerin and water was used. The procedure to obtain a proper 3D-printed model using low-force stereolithography technology with high-quality optical access usable for PIV was described and discussed. The paper presents the results of PIV as multi-stitched, color-coded vector maps from the axis cross section along the whole 3D-printed model. The obtained data allowed a resolution of 100 × 100 µm per single vector to be achieved. Furthermore, the results of the stitched 16 base images of the artery and the 3D-printed model prepared were included. The results of this study show that 3D prints allow for the creation of the desired geometry and can be used to investigate severe pathologies of the human circulatory system. The strengths and weaknesses of this methodology were discussed and compared to other techniques used to obtain transparent objects.
Air quality is an important factor for human well-being, and it is crucial that when using mechanical ventilation system, air is properly distributed so it reaches every user of a ventilated zone. To improve ventilation systems, and in consequence the air quality, this paper focuses on studying the impact of an air terminal device (ATD) with a dynamically changing geometry on the effectiveness of a variable air volume (VAV) ventilation system. VAV system characterizes a change in the airflow magnitude through the system when the heat gains lower, which may be a risk for human health as air may not reach the furthest parts of a zone. To combat this threat, an ATD with a dynamically changing geometry was installed. As a ventilation quality indicator, the air throw was taken under consideration. Thanks to the new ATD, the steady air throw should be maintained despite the changes in flow in the ventilation system. To achieve this, the research was divided into two stages. The first stage included a series of computational fluid dynamics simulations that considered the alteration of the airflow and the air terminal device diameter. Afterwards, verifying laboratory measurements were conducted on a laboratory stand using a particle image velocimetry (PIV) system that included an air terminal device with a changing geometry. The results of the simulations and the PIV measurements showed that the changes in the geometry of the air terminal device improve the ventilation effectiveness of a VAV system, allowing the system to maintain a constant air throw despite the changing airflow magnitude through the system.