Jarno Groenesteijn

Mr. Jarno Groenesteijn


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Micromachines
Verified
Journal Article
Open access
PDF file
WSWouter Sparreboom
Wouter Sparreboom
JGJan Van de Geest
Jan Van de Geest
MKMarcel Katerberg
Marcel Katerberg
FPFerry Postma
Ferry Postma
JHJeroen Haneveld
Jeroen Haneveld
JLJoost Lötters
Joost Lötters
In this paper we demonstrate a compact ready-to-use micro Coriolis mass flow meter. The full scale flow is 1 g/h (for water at a pressure drop < 1 bar). It has a zero stability of 2 mg/h and an accuracy of 0.5% reading for both liquids and gases. The temperature drift between 10 and 50 °C is below 1 mg/h/°C. The meter is robust, has standard fluidic connections and can be read out by means of a PC or laptop via USB. Its performance was tested for several common gases (hydrogen, helium, nitrogen, argon and air) and liquids (water and isopropanol). As in all Coriolis mass flow meters, the meter is also able to measure the actual density of the medium flowing through the tube. The sensitivity of the measured density is ~1 Hz.m3/kg.

1 November 2015
Verified
Conference Paper
Closed access
JTJoel van Tiem
Joel van Tiem
JGJarno Groenesteijn
Jarno Groenesteijn
RSRemco Sanders
Remco Sanders
GKGijs Krijnen
Gijs Krijnen
We present a biomimetic angular acceleration sensor inspired by the vestibular system, as found e.g. in mammals and fish. The sensor consist of a fluid filled circular channel. When exposed to angular accelerations the fluid flows relative to the channel. Read-out is based on electromagnetic flow sensing (pseudo Hall effect). The sensor is made out of two 3D printed parts which, when put together, form a channel and which allow for easy mounting of permanent magnets and electrodes to measure the flow induced potential difference. Experiments indeed show an acceleration dependent output voltage. However, we find strong contributions from other than electromagnetic sources which, due to their nature and magnitude, are interesting for further research.

10 July 2017 in Microfluidics and Nanofluidics
Verified
Journal Article
Open access
PDF file
JGJarno Groenesteijn
Jarno Groenesteijn
MBMeint J. de Boer
Meint J. de Boer
JLJoost C. Lötters
Joost C. Lötters
RWRemco Wiegerink
Remco Wiegerink
Many microfluidic devices are made using specialized fabrication processes, limiting the ability to integrate those devices on the same chip. In this paper, a versatile technology platform is presented that allows for integration of many different devices. It provides a method to design channels in a wide range of sizes and shapes with different functionalization options in close proximity to the fluid in the channels. The latter includes release of the channels for thermal isolation or mechanical movement and metal or piezoelectric layers for actuation and read-out. The channel walls are made using silicon-rich silicon nitride to provide durable, strong, chemically inert and thermally stable channels directly below the substrate surface .

15 March 2012 in Micromachines
Verified
Journal Article
Open access
PDF file
JLJoost Lötters
Joost Lötters
TLTheo S.J. Lammerink
Theo S.J. Lammerink
JGJarno Groenesteijn
Jarno Groenesteijn
JHJeroen Haneveld
Jeroen Haneveld
RWRemco Wiegerink
Remco Wiegerink
We have realized a micromachined single chip flow sensing system with an ultra-wide dynamic flow range of more than five decades, from 100 nL/h up to more than 10 mL/h. The system comprises both a thermal and a micro Coriolis flow sensor with partially overlapping flow ranges.

1 March 2017 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
RMRosa Monge
Rosa Monge
JGJarno Groenesteijn
Jarno Groenesteijn
DADennis Alveringh
Dennis Alveringh
RWRemco Wiegerink
Remco Wiegerink
JLJoost Lötters
Joost Lötters
LFLuis Fernandez
Luis Fernandez

10 April 2015 in Micromachines
Verified
Journal Article
Open access
PDF file
EWEgbert Van Der Wouden
Egbert Van Der Wouden
JGJarno Groenesteijn
Jarno Groenesteijn
RWRemco Wiegerink
Remco Wiegerink
JLJoost Lötters
Joost Lötters
In this paper we describe the development of a system and model to analyze the composition of gas mixtures up to four components. The system consists of a Coriolis mass flow sensor, density, pressure and thermal flow sensor. With this system it is possible to measure the viscosity, density, heat capacity and flow rate of the medium. In a next step the composition can be analyzed if the constituents of the mixture are known. This makes the approach universally applicable to all gasses as long as the number of components does not exceed the number of measured properties and as long as the properties are measured with a sufficient accuracy. We present measurements with binary and ternary gas mixtures, on compositions that range over an order of magnitude in value for the physical properties. Two platforms for analyses are presented. The first platform consists of sensors realized with MEMS fabrication technology. This approach allows for a system with a high level of integration. With this system we demonstrate a proof of principle for the analyses of binary mixtures with an accuracy of 10%. In the second platform we utilize more mature steel sensor technology to demonstrate the potential of this approach. We show that with this technique, binary mixtures can be measured within 1% and ternary gas mixtures within 3%.