Joost Lötters

Dr. Joost Lötters

1 Integrated Devices and Systems (IDS), MESA+ Institute for Nanotechnology, University of Twente, PO Box 217, 7500 AE Enschede, The Netherlands
+1
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2012 in Micromachines
Verified
Journal Article
Open access
PDF file
JLJoost Lötters
Joost Lötters
TLTheo S.J. Lammerink
Theo S.J. Lammerink
JGJarno Groenesteijn
Jarno Groenesteijn
JHJeroen Haneveld
Jeroen Haneveld
RWRemco Wiegerink
Remco Wiegerink
We have realized a micromachined single chip flow sensing system with an ultra-wide dynamic flow range of more than five decades, from 100 nL/h up to more than 10 mL/h. The system comprises both a thermal and a micro Coriolis flow sensor with partially overlapping flow ranges.

21 June 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
SKShirin Azadi Kenari
Shirin Azadi Kenari
RWRemco Wiegerink
Remco Wiegerink
HVHenk-Willem Veltkamp
Henk-Willem Veltkamp
RSRemco G. P. Sanders
Remco G. P. Sanders
JLJoost Lötters
Joost Lötters
This paper presents a novel gas-independent thermal flow sensor chip featuring three calorimetric flow sensors for measuring flow profile and direction within a tube, along with a single-wire flow independent thermal conductivity sensor capable of identifying the gas type through a simple DC voltage measurement. All wires have the same dimensions of 2000 μm in length, 5 μm in width, and 1.2 μm in thickness. The design theory and COMSOL simulation are discussed and compared with the measurement results. The sensor’s efficacy is demonstrated with different gases, He, N2, Ar, and CO2, for thermal conductivity and thermal flow measurements. The sensor can accurately measure the thermal conductivity of various gases, including air, enabling correction of flow rate measurements based on the fluid type. The measured voltage from the thermal conductivity sensor for air corresponds to a calculated thermal conductivity of 0.02522 [W/m·K], with an error within 2.9%.

10 April 2015 in Micromachines
Verified
Journal Article
Open access
PDF file
EWEgbert Van Der Wouden
Egbert Van Der Wouden
JGJarno Groenesteijn
Jarno Groenesteijn
RWRemco Wiegerink
Remco Wiegerink
JLJoost Lötters
Joost Lötters
In this paper we describe the development of a system and model to analyze the composition of gas mixtures up to four components. The system consists of a Coriolis mass flow sensor, density, pressure and thermal flow sensor. With this system it is possible to measure the viscosity, density, heat capacity and flow rate of the medium. In a next step the composition can be analyzed if the constituents of the mixture are known. This makes the approach universally applicable to all gasses as long as the number of components does not exceed the number of measured properties and as long as the properties are measured with a sufficient accuracy. We present measurements with binary and ternary gas mixtures, on compositions that range over an order of magnitude in value for the physical properties. Two platforms for analyses are presented. The first platform consists of sensors realized with MEMS fabrication technology. This approach allows for a system with a high level of integration. With this system we demonstrate a proof of principle for the analyses of binary mixtures with an accuracy of 10%. In the second platform we utilize more mature steel sensor technology to demonstrate the potential of this approach. We show that with this technique, binary mixtures can be measured within 1% and ternary gas mixtures within 3%.

25 February 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
HVHenk-Willem Veltkamp
Henk-Willem Veltkamp
FMFernanda Akegawa Monteiro
Fernanda Akegawa Monteiro
RSRemco G. P. Sanders
Remco G. P. Sanders
RWRemco Wiegerink
Remco Wiegerink
JLJoost Lötters
Joost Lötters
Fast point-of-use detection of, for example, early-stage zoonoses, e.g., Q-fever, bovine tuberculosis, or the Covid-19 coronavirus, is beneficial for both humans and animal husbandry as it can save lives and livestock. The latter prevents farmers from going bankrupt after a zoonoses outbreak. This paper describes the development of a fabrication process and the proof-of-principle of a disposable DNA amplification chip with an integrated heater. Based on the analysis of the milling process, metal adhesion studies, and COMSOL MultiPhysics heat transfer simulations, the first batch of chips has been fabricated and successful multiple displacement amplification reactions are performed inside these chips. This research is the first step towards the development of an early-stage zoonoses detection device. Tests with real zoonoses and DNA specific amplification reactions still need to be done.

27 April 2012 in Micromachines
Verified
Journal Article
Open access
PDF file
MGMaarten Groen
Maarten Groen
DBDannis M. Brouwer
Dannis M. Brouwer
RWRemco Wiegerink
Remco Wiegerink
JLJoost Lötters
Joost Lötters
Precise mass flow control is an essential requirement for novel, small-scale fluidic systems. However, a small-volume, low-leakage proportional control valve for minute fluid flows has not yet been designed or manufactured. A survey is therefore made of the primary design considerations of a micromachined, proportional control valve. Performance requirements are identified based on various applications. Valve operating principles and actuation schemes presented in the literature are evaluated with respect to functionality and technological feasibility. Proceeding from these analyses, we identify the design concepts and actuation schemes that we think are best suited for the fabrication of the intended microvalve.

11 February 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
TSThomas Schut
Thomas Schut
RWRemco Wiegerink
Remco Wiegerink
JLJoost Lötters
Joost Lötters
This paper presents a μ -Coriolis mass flow sensor with resistive readout. Instead of measuring a net displacement such as in a capacitive readout, a resistive readout detects the deformation of the suspended micro-fluidic channel. It allows for actuation at much higher amplitudes than for a capacitive readout, resulting in correspondingly larger Coriolis forces in response to fluid flow. A resistive readout can be operated in two actuation vibrational modes. A capacitive readout can only be operated in one of these two modes, which is more sensitive to external disturbances. Three types of devices have been realized. We present measurement results for all three devices. One device clearly outperforms the other two, with a flow sensitivity of 2.22 °/(g·h−1) and a zero-flow stability of 0.02 g·h−1 over 30 min. Optimization of the metal strain gauges and/or implementation of poly-Silicon strain gauges could further improve performance.