Mang Ou-Yang

Prof. Mang Ou-Yang

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2021 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
YYYung-Jhe Yan
Yung-Jhe Yan
BWBo-Wen Wang
Bo-Wen Wang
CYChih-Man Yang
Chih-Man Yang
C吳Ching-Yi 吳靜宜
Ching-Yi 吳靜宜
MOMang Ou-Yang
Mang Ou-Yang
The use of fluorescence spectroscopy for plaque detection is a fast and effective way to monitor oral health. At present, there is no uniform specification for the design of the excitation light source of related products for generating fluorescence. To carry out experiments on dental plaque, the fluorescence spectra of three different bacterial species (Porphyromonas gingivalis, Aggregatibacter actinomycetemcomitans, and Streptococcus mutans) were measured by hyperspectral imaging microscopy (HIM). Three critical issues were found in the experiments. One issue was the unwanted spectrum generated from a mercury line source; two four-order low-pass filters were evaluated for eliminating the unwanted spectrum and meet the experimental requirements. The second issue was the red fluorescence generated from the microscope slide made of borosilicate glass; this could affect the observation of the red fluorescence from the bacteria; quartz microscope slides were found to reduce the fluorescence intensity by about 2 dB compared with the borosilicate slide. The third issue of photobleaching in the fluorescence of the Porphyromonas gingivalis was studied. This study proposes a method of classifying three bacteria based on the spectral intensity ratios (510/635 and 500/635 nm) under the 405 nm excitation light was proposed in this study. The sensitivity and specificity of the classification were approximately 99% and 99%, respectively.

1 September 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YYYung-Jhe Yan
Yung-Jhe Yan
CLChun-Chieh Liao
Chun-Chieh Liao
TWTing-Feng Wang
Ting-Feng Wang
MOMang Ou-Yang
Mang Ou-Yang
The De-Bruijn sequences could provide appropriate circular arrangements to achieve a single-track absolute rotary optical encoder in the servo motor application. One example used popularly is the maximum length sequences. High-resolution single-track encoders need a sensor array to obtain the position signal simultaneously. Nevertheless, the individual photocurrents would interference by other adjacent photocurrents, like the photocurrent blooming. The circumstances would increase the bias noise for the digital binarization. The concept in this paper would try to find the optimal De-Bruijn sequences to reduce the photocurrent blooming interference intrinsically without signal process remodification. Three different types of the 9-bits codes, the adjacent De-Bruijn code, the quarter De-Bruijn codes, and the optimal De-Bruijn codes, are analyzed, manufactured, and experimented in the actual encoders. Based on the open-factor of the eye-diagram, the adjacent De-Bruijn code has 0.328 and would be the worse signal quality in De-Bruijn sequences. The quarter De-Bruijn codes have 0.386 of the open-factor with 17.7% improvement to adjacent De-Bruijn code. Finally, the optimal De-Bruijn codes have 0.436 of the open-factor with 32.9% improvement to the traditional M-code. The fact would mean the possible ability of 3-bits progress from 9-bits of adjacent De-Bruijn code to 12-bits of the optimal De-Bruijn codes under the same signal-to-noise ratio.

1 April 2017 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
YYYung-Jhe Yan
Yung-Jhe Yan
THTing-Wei Huang
Ting-Wei Huang
NCNai-Lun Cheng
Nai-Lun Cheng
YHYao-Fang Hsieh
Yao-Fang Hsieh
MTMing-Hsui Tsai
Ming-Hsui Tsai
MOMang Ou-Yang
Mang Ou-Yang
Oral cancer is a serious and growing problem in many developing and developed countries. To improve the cancer screening procedure, we developed a portable light-emitting-diode (LED)-induced autofluorescence (LIAF) imager that contains two wavelength LED excitation light sources and multiple filters to capture ex vivo oral tissue autofluorescence images. Compared with conventional means of oral cancer diagnosis, the LIAF imager is a handier, faster, and more highly reliable solution. The compact design with a tiny probe allows clinicians to easily observe autofluorescence images of hidden areas located in concave deep oral cavities. The ex vivo trials conducted in Taiwan present the design and prototype of the portable LIAF imager used for analyzing 31 patients with 221 measurement points. Using the normalized factor of normal tissues under the excitation source with 365 nm of the central wavelength and without the bandpass filter, the results revealed that the sensitivity was larger than 84%, the specificity was not smaller than over 76%, the accuracy was about 80%, and the area under curve of the receiver operating characteristic (ROC) was achieved at about 87%, respectively. The fact shows the LIAF spectroscopy has the possibilities of ex vivo diagnosis and noninvasive examinations for oral cancer.

1 October 2007 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
MOMang Ou-Yang
Mang Ou-Yang
SHShih-Wei Huang
Shih-Wei Huang
YCYung-Lin Chen
Yung-Lin Chen
HLHsin-Hung Lee
Hsin-Hung Lee
PWPing-Kuo Weng
Ping-Kuo Weng
Use of the capsule endoscope to inspect the digestive system, and in particular the intestine, for pathological change has recently been a great breakthrough in medical engineering. Some problems, however, need to be overcome. The field of view is not wide enough, and the image quality is not good enough. These drawbacks cause unclear and ambiguous digestive disease examinations by medical professionals. In order to solve these problems, the paper proposes a novel design for miniature lenses with a wide-angle field of view and good imaging quality. The lenses employed in the capsule endoscope would consist of a plastic aspheric lens and a glass lens, in a capsule 9.8mm(W)×9.8mm(L)×10.7mm(H), associated with white LED light sources and a 256×256 CMOS array sensor of 10-μm pixel size. Experimental results prove that the lens field of view can be made as large as 86deg, and the modulation transfer function for field of view 0deg can be made 78.2% at 50-lp∕mm spatial frequency and 53.3% at 100lp∕mm. Tolerance analysis shows that our design is feasible for manufacture, and consistent with the finished prototype.

17 February 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CCChih-Jung Chen
Chih-Jung Chen
YYYung-Jhe Yan
Yung-Jhe Yan
CHChi-Cho Huang
Chi-Cho Huang
JCJen-Tzung Chien
Jen-Tzung Chien
CCChang-Ting Chu
Chang-Ting Chu
MOMang Ou-Yang
Mang Ou-Yang
Sugariness is one of the most important indicators to measure the quality of Syzygium samarangense, which is also known as the wax apple. In general, farmers used to measure sugariness by testing the extracted juice of the wax apple products. Such a destructive way to measure sugariness is not only labor-consuming but also wasting products. Therefore, non-destructive and quick techniques for measuring sugariness would be significant for wax apple supply chains. Traditionally, the non-destructive method to predict the sugariness or the other indicators of the fruits was based on the reflectance spectra or Hyperspectral Images (HSIs) using linear regression such as Multi-Linear Regression (MLR), Principal Component Regression (PCR), and Partial Least Square Regression (PLSR), etc. However, these regression methods are usually too simple to precisely estimate the complicated mapping between the reflectance spectra or HSIs and the sugariness. This study presents the deep learning methods for sugariness prediction using the reflectance spectra or HSIs from the bottom of the wax apple. A non-destructive imaging system fabricated with two spectrum sensors and light sources is implemented to acquire the visible and infrared lights with a range of wavelengths. In particular, a specialized Convolutional Neural Network (CNN) with hyperspectral imaging is proposed by investigating the effect of different wavelength bands for sugariness prediction. Rather than extracting spatial features, the proposed CNN model was designed to extract spectral features of HSIs. In the experiments, the ground-truth value of sugariness is obtained from a commercial refractometer. The experimental results show that using the whole band range between 400 and 1700 nm achieves the best performance in terms of °Brix error. CNN models attain the °Brix error of ± 0.552, smaller than ± 0.597 using Feedforward Neural Network (FNN). Significantly, the CNN’s test results show that the minor error in the interval 0 to 10°Brix and 10 to 11°Brix are ± 0.551 and ± 0.408, these results indicate that the model would have the capability to predict if sugariness is below 10°Brix or not, which would be similar to the human tongue. These results are much better than ± 1.441 and ± 1.379 by using PCR and PLSR, respectively. Moreover, this study provides the test error in each °Brix interval within one Brix, and the results show that the test error is varied considerably within different °Brix intervals, especially on PCR and PLSR. On the other hand, FNN and CNN obtain robust results in terms of test error.

1 May 2012 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
MOMang Ou-Yang
Mang Ou-Yang
WJWei-De Jeng
Wei-De Jeng
YWYin-Yi Wu
Yin-Yi Wu
LDLan-Rong Dung
Lan-Rong Dung
HWHsien-Ming Wu
Hsien-Ming Wu
LCLuan-Jiau Chiu
Luan-Jiau Chiu
This study investigates image processing using the radial imaging capsule endoscope (RICE) system. First, an experimental environment is established in which a simulated object has a shape that is similar to a cylinder, such that a triaxial platform can be used to push the RICE into the sample and capture radial images. Then four algorithms (mean absolute error, mean square error, Pearson correlation coefficient, and deformation processing) are used to stitch the images together. The Pearson correlation coefficient method is the most effective algorithm because it yields the highest peak signal-to-noise ratio, higher than 80.69 compared to the original image. Furthermore, a living animal experiment is carried out. Finally, the Pearson correlation coefficient method and vector deformation processing are used to stitch the images that were captured in the living animal experiment. This method is very attractive because unlike the other methods, in which two lenses are required to reconstruct the geometrical image, RICE uses only one lens and one mirror.