Yung-Jhe Yan

Dr. Yung-Jhe Yan

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2021 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
YYYung-Jhe Yan
Yung-Jhe Yan
BWBo-Wen Wang
Bo-Wen Wang
CYChih-Man Yang
Chih-Man Yang
C吳Ching-Yi 吳靜宜
Ching-Yi 吳靜宜
MOMang Ou-Yang
Mang Ou-Yang
The use of fluorescence spectroscopy for plaque detection is a fast and effective way to monitor oral health. At present, there is no uniform specification for the design of the excitation light source of related products for generating fluorescence. To carry out experiments on dental plaque, the fluorescence spectra of three different bacterial species (Porphyromonas gingivalis, Aggregatibacter actinomycetemcomitans, and Streptococcus mutans) were measured by hyperspectral imaging microscopy (HIM). Three critical issues were found in the experiments. One issue was the unwanted spectrum generated from a mercury line source; two four-order low-pass filters were evaluated for eliminating the unwanted spectrum and meet the experimental requirements. The second issue was the red fluorescence generated from the microscope slide made of borosilicate glass; this could affect the observation of the red fluorescence from the bacteria; quartz microscope slides were found to reduce the fluorescence intensity by about 2 dB compared with the borosilicate slide. The third issue of photobleaching in the fluorescence of the Porphyromonas gingivalis was studied. This study proposes a method of classifying three bacteria based on the spectral intensity ratios (510/635 and 500/635 nm) under the 405 nm excitation light was proposed in this study. The sensitivity and specificity of the classification were approximately 99% and 99%, respectively.

1 September 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YYYung-Jhe Yan
Yung-Jhe Yan
CLChun-Chieh Liao
Chun-Chieh Liao
TWTing-Feng Wang
Ting-Feng Wang
MOMang Ou-Yang
Mang Ou-Yang
The De-Bruijn sequences could provide appropriate circular arrangements to achieve a single-track absolute rotary optical encoder in the servo motor application. One example used popularly is the maximum length sequences. High-resolution single-track encoders need a sensor array to obtain the position signal simultaneously. Nevertheless, the individual photocurrents would interference by other adjacent photocurrents, like the photocurrent blooming. The circumstances would increase the bias noise for the digital binarization. The concept in this paper would try to find the optimal De-Bruijn sequences to reduce the photocurrent blooming interference intrinsically without signal process remodification. Three different types of the 9-bits codes, the adjacent De-Bruijn code, the quarter De-Bruijn codes, and the optimal De-Bruijn codes, are analyzed, manufactured, and experimented in the actual encoders. Based on the open-factor of the eye-diagram, the adjacent De-Bruijn code has 0.328 and would be the worse signal quality in De-Bruijn sequences. The quarter De-Bruijn codes have 0.386 of the open-factor with 17.7% improvement to adjacent De-Bruijn code. Finally, the optimal De-Bruijn codes have 0.436 of the open-factor with 32.9% improvement to the traditional M-code. The fact would mean the possible ability of 3-bits progress from 9-bits of adjacent De-Bruijn code to 12-bits of the optimal De-Bruijn codes under the same signal-to-noise ratio.

25 June 2021 in Brain Sciences
Verified
Journal Article
Open access
PDF file
YYYung-Jhe Yan
Yung-Jhe Yan
CCChien-Nan Chen
Chien-Nan Chen
MOMang Ou-Yang
Mang Ou-Yang
This study proposed a pupillary light reflex (PLR) inherent model based on the system identification method to demonstrate the dynamic physiological mechanism of the PLR, in which pupillary constriction and dilation are controlled by the sympathetic and parasympathetic nervous system. This model was constructed and verified by comparing the simulated and predicted PLR response with that of healthy participants. The least root-mean-square error (RMSE) of simulated PLR response was less than 0.7% when stimulus duration was under 3 ms. The RMSE of predicted PLR response increased by approximately 6.76%/s from the stimulus duration of 1 ms to 3 s, when the model directly used the parameters extracted from the PLR at the stimulus duration of 10 ms. When model parameters were derived from the regression by the measured PLR response, the RMSE kept under 8.5%. The model was applied to explore the PLR abnormalities of the people with Diabetic Mellitus (DM) by extracting the model parameters from 42 people with DM and comparing these parameters with those of 42 healthy participants. The parameter in the first-order term of the elastic force of the participants with DM was significantly lower than that of the healthy participants (p < 0.05). The sympathetic force and sympathetic action delay of the participants with DM were significantly larger (p < 0.05) and longer (p < 0.0001) than that of the healthy ones, respectively. The reason might be that the sympathetic nervous system, which controls the dilator muscle, degenerated in diabetic patients.

6 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YYYung-Jhe Yan
Yung-Jhe Yan
NCNai-Lun Cheng
Nai-Lun Cheng
CJChia-Ing Jan
Chia-Ing Jan
MTMing-Hsui Tsai
Ming-Hsui Tsai
JCJin-Chern Chiou
Jin-Chern Chiou
MOMang Ou-Yang
Mang Ou-Yang
This aim of this study was to find effective spectral bands for the early detection of oral cancer. The spectral images in different bands were acquired using a self-made portable light-emitting diode (LED)-induced autofluorescence multispectral imager equipped with 365 and 405 nm excitation LEDs, emission filters with center wavelengths of 470, 505, 525, 532, 550, 595, 632, 635, and 695 nm, and a color image sensor. The spectral images of 218 healthy points in 62 healthy participants and 218 tumor points in 62 patients were collected in the ex vivo trials at China Medical University Hospital. These ex vivo trials were similar to in vivo because the spectral images of anatomical specimens were immediately acquired after the on-site tumor resection. The spectral images associated with red, blue, and green filters correlated with and without nine emission filters were quantized by four computing method, including summated intensity, the highest number of the intensity level, entropy, and fractional dimension. The combination of four computing methods, two excitation light sources with two intensities, and 30 spectral bands in three experiments formed 264 classifiers. The quantized data in each classifier was divided into two groups: one was the training group optimizing the threshold of the quantized data, and the other was validating group tested under this optimized threshold. The sensitivity, specificity, and accuracy of each classifier were derived from these tests. To identify the influential spectral bands based on the area under the region and the testing results, a single-layer network learning process was used. This was compared to conventional rules-based approaches to show its superior and faster performance. Consequently, four emission filters with the center wavelengths of 470, 505, 532, and 550 nm were selected by an AI-based method and verified using a rule-based approach. The sensitivities of six classifiers using these emission filters were more significant than 90%. The average sensitivity of these was about 96.15%, the average specificity was approximately 69.55%, and the average accuracy was about 82.85%.

23 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YTYu-Hsiang Tsai
Yu-Hsiang Tsai
YYYung-Jhe Yan
Yung-Jhe Yan
MHMeng-Hsin Hsiao
Meng-Hsin Hsiao
TYTzu-Yi Yu
Tzu-Yi Yu
MOMang Ou-Yang
Mang Ou-Yang
In this study, an information fusion system displayed fusion information on a transparent display by considering the relationships among the display, background exhibit, and user’s gaze direction. We used an ARM-based field-programmable gate array (FPGA) to perform virtual–real fusion of this system as well as evaluated the virtual–real fusion execution speed. The ARM-based FPGA used Intel® RealsenseTM D435i depth cameras to capture depth and color images of an observer and exhibit. The image data was received by the ARM side and fed to the FPGA side for real-time object detection. The FPGA accelerated the computation of the convolution neural networks to recognize observers and exhibits. In addition, a module performed by the FPGA was developed for rapid registration between the color and depth images. The module calculated the size and position of the information displayed on a transparent display according to the pixel coordinates and depth values of the human eye and exhibit. A personal computer with GPU RTX2060 performed information fusion in ~47 ms, whereas the ARM-based FPGA accomplished it in 25 ms. Thus, the fusion speed of the ARM-based FPGA was 1.8 times faster than on the computer.

1 June 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
YTY. H. Tsai
Y. H. Tsai
YYYung-Jhe Yan
Yung-Jhe Yan
YLY. S. Li
Y. S. Li
CCC. H. Chang
C. H. Chang
CHC. C. Haung
C. C. Haung
MOMang Ou-Yang
Mang Ou-Yang
A hyperspectral imaging system (HIS) is a helpful tool that acquires spatial and spectral information from a target. This study developed a coaxial heterogeneous HIS (CHHIS) to collect spectral images with wavelengths ranging from 400 to 1700 nm. In this system, a visible (VIS) spectrometer and a short-wave infrared (SWIR) spectrometer are combined with a coaxial optical path to share the same field of view. This structure reduces the complexity of spatial registration and maintains the scanning duration of two spectrometers as that of a single spectrometer. The spectrometers are also replaceable for extending the detecting spectral range of the system. The calibration methodologies, including spatial correction, spectral calibration, and reflectance calibration, were developed for this system. The signal-to-noise ratio of VIS and SWIR spectrometers in the CHHIS was up to 40 and 60 dB when the exposure time of the VIS and SWIR imaging sensors was 1000 and 10 ms, respectively. When the target distance was at 600 mm, the spatial error of VIS and SWIR images in the scanning direction was less than 1 pixel; these results proved that the system was stable.