Yuu Ono

Dr. Yuu Ono


Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2002 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JKJ. Kushibiki
J. Kushibiki
YOYuu Ono
Yuu Ono
YOY. Ohashi
Y. Ohashi
MAM. Arakawa
M. Arakawa
A line-focus-beam ultrasonic material characterization (LFB-UMC) system has been developed to evaluate large diameter crystals and wafers currently used in electronic devices. The system enables highly accurate detection of slight changes in the physical and chemical properties in and among specimens. Material characterization proceeds by measuring the propagation characteristics, viz., phase velocity and attenuation, of Rayleigh-type leaky surface acoustic waves (LSAWs) excited on the water-loaded specimen surface. The measurement accuracy depends mainly upon the translation accuracy of the mechanical stages used in the system and the stability of the temperature environment. New precision mechanical translation stages have been developed, and the mechanical system, including the ultrasonic device and the specimen, has been installed in a temperature-controlled chamber to reduce thermal convection and conduction at the specimen. A method for precisely measuring temperature and longitudinal velocity in the water couplant has been developed, and a measurement procedure for precisely measuring the LSAW velocities has been completed, achieving greater relative accuracy to better than /spl plusmn/0.002% at any single chosen point and /spl plusmn/0.004% for two-dimensional measurements over a scanning area of a 200-mm diameter silicon single-crystal substrate. The system was developed to address various problems arising in science and industry associated with the development of materials and device fabrication processes.

27 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
IAIbrahim AlMohimeed
Ibrahim AlMohimeed
YOYuu Ono
Yuu Ono
Skeletal muscle is considered as a near-constant volume system, and the contractions of the muscle are related to the changes in tissue thickness. Assessment of the skeletal muscle contractile parameters such as maximum contraction thickness ( T h ), contraction time ( T c ), contraction velocity ( V c ), sustain time ( T s ), and half-relaxation ( T r ) provides valuable information for various medical applications. This paper presents a single-element wearable ultrasonic sensor (WUS) and a method to measure the skeletal muscle contractile parameters in A-mode ultrasonic data acquisition. The developed WUS was made of double-layer polyvinylidene fluoride (PVDF) piezoelectric polymer films with a simple and low-cost fabrication process. A flexible, lightweight, thin, and small size WUS would provide a secure attachment to the skin surface without affecting the muscle contraction dynamics of interest. The developed WUS was employed to monitor the contractions of gastrocnemius (GC) muscle of a human subject. The GC muscle contractions were evoked by the electrical muscle stimulation (EMS) at varying EMS frequencies from 2 Hz up to 30 Hz. The tissue thickness changes due to the muscle contractions were measured by utilizing a time-of-flight method in the ultrasonic through-transmission mode. The developed WUS demonstrated the capability to monitor the tissue thickness changes during the unfused and fused tetanic contractions. The tetanic progression level was quantitatively assessed using the parameter of the fusion index (FI) obtained. In addition, the contractile parameters ( T h , T c , V c , T s , and T r ) were successfully extracted from the measured tissue thickness changes. In addition, the unfused and fused tetanus frequencies were estimated from the obtained FI-EMS frequency curve. The WUS and ultrasonic method proposed in this study could be a valuable tool for inexpensive, non-invasive, and continuous monitoring of the skeletal muscle contractile properties.

1 July 2013
Verified
Conference Paper
Closed access
IAIbrahim AlMohimeed
Ibrahim AlMohimeed
HTHisham Turkistani
Hisham Turkistani
YOYuu Ono
Yuu Ono
A wearable and flexible ultrasonic sensor was developed for monitoring of skeletal muscle contraction. The sensor was constructed using a PVDF piezoelectric polymer film without a matching layer or backing material. Due to its lightness (less than 1 gram), thinness (200 μm) and flexibility, this sensor was wearable and enabled non-invasive and continuous muscle monitoring without restricting muscle movement, which is not feasible using a conventional handheld ultrasonic probe. The developed sensor was used to monitor muscle contractions in the index finger by ultrasonic pulse-echo measurements and in the forearm by through-transmission measurements. It was successfully demonstrated that the tissue thickness variations were measured in accordance with the muscle contraction performed.

16 January 2006 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Makiko KobayashiMakiko Kobayashi
Makiko Kobayashi
YOYuu Ono
Yuu Ono
CJCheng-Kuei Jen
Cheng-Kuei Jen
CCChin-Chi Cheng
Chin-Chi Cheng
Thick-film (90 /spl mu/m) piezoelectric ceramic high-temperature ultrasonic transducers (HTUTs) have been successfully deposited on metallic substrates by a sol-gel spray technique. The gel is composed of fine powders of bismuth titanate dispersed in a lead-zirconate-titanate solution. The films with desired thickness have been obtained through multilayer coating approach. Piezoelectricity is achieved using the corona discharge poling method. The center frequencies of ultrasonic signals generated by these HTUTs are around 10 MHz and their signal-to-noise ratio (SNR) is more than 30 dB in pulse-echo mode at 500/spl deg/C. The main advantages of these new HTUTs are that they 1) are applicable at temperatures higher than 500/spl deg/C, 2) are miniature, 3) can be coated on flat and curved surfaces, 4) do not need ultrasonic couplant, 5) can be operated at low and medium megahertz frequency range with sufficient frequency bandwidth, and 6) have sufficient piezoelectric strength and SNR. The ability of the HTUTs to monitor the polymer injection molding process in real-time at the mold insert of the machine is demonstrated.

1 August 2007 in Polymer Engineering & Science
Verified
Journal Article
Closed access
PDF file
CCChin‐Chi Cheng
Chin‐Chi Cheng
YOYuu Ono
Yuu Ono
CJCheng‐Kuei Jen
Cheng‐Kuei Jen

25 January 2022 in IEEE Instrumentation & Measurement Magazine
Verified
Journal Article
Closed access
SSShane Steinberg
Shane Steinberg
AHAndy Huang
Andy Huang
YOYuu Ono
Yuu Ono
SRSreeraman Rajan
Sreeraman Rajan
Wearable health monitoring systems for ubiquitous and continuous evaluation of physiological status are facilitating a paradigm shift in the way healthcare will be delivered in the coming years. As the aging demographic in many developed countries increases, rising healthcare costs and strained hospital resources will result. Furthermore, as the pace of aging in the world is faster than in the past, according to the World Health Organization all countries will face challenges while providing health care to its citizens [1]. Home-based monitoring using low-cost wearable technologies that are capable of automatic diagnosis and supervising the physiological status of subjects may alleviate the excessive demand on the healthcare system. These systems require the development of novel sensor and measurement strategies to automate monitoring of the physiological parameters of interest. Such sensors and measurement systems must be lightweight and have low power consumption, as subjects would have to wear them continuously for long periods of time. Our research group has been developing wearable ultrasonic sensor (WUS) technology for monitoring the dynamical properties of soft tissues [2] in several areas of application.