Skeletal muscle is considered as a near-constant volume system, and the contractions of the muscle are related to the changes in tissue thickness. Assessment of the skeletal muscle contractile parameters such as maximum contraction thickness ( ), contraction time ( ), contraction velocity ( ), sustain time ( ), and half-relaxation ( ) provides valuable information for various medical applications. This paper presents a single-element wearable ultrasonic sensor (WUS) and a method to measure the skeletal muscle contractile parameters in A-mode ultrasonic data acquisition. The developed WUS was made of double-layer polyvinylidene fluoride (PVDF) piezoelectric polymer films with a simple and low-cost fabrication process. A flexible, lightweight, thin, and small size WUS would provide a secure attachment to the skin surface without affecting the muscle contraction dynamics of interest. The developed WUS was employed to monitor the contractions of gastrocnemius (GC) muscle of a human subject. The GC muscle contractions were evoked by the electrical muscle stimulation (EMS) at varying EMS frequencies from 2 Hz up to 30 Hz. The tissue thickness changes due to the muscle contractions were measured by utilizing a time-of-flight method in the ultrasonic through-transmission mode. The developed WUS demonstrated the capability to monitor the tissue thickness changes during the unfused and fused tetanic contractions. The tetanic progression level was quantitatively assessed using the parameter of the fusion index (FI) obtained. In addition, the contractile parameters ( , , , , and ) were successfully extracted from the measured tissue thickness changes. In addition, the unfused and fused tetanus frequencies were estimated from the obtained FI-EMS frequency curve. The WUS and ultrasonic method proposed in this study could be a valuable tool for inexpensive, non-invasive, and continuous monitoring of the skeletal muscle contractile properties.
A wearable and flexible ultrasonic sensor was developed for monitoring of skeletal muscle contraction. The sensor was constructed using a PVDF piezoelectric polymer film without a matching layer or backing material. Due to its lightness (less than 1 gram), thinness (200 μm) and flexibility, this sensor was wearable and enabled non-invasive and continuous muscle monitoring without restricting muscle movement, which is not feasible using a conventional handheld ultrasonic probe. The developed sensor was used to monitor muscle contractions in the index finger by ultrasonic pulse-echo measurements and in the forearm by through-transmission measurements. It was successfully demonstrated that the tissue thickness variations were measured in accordance with the muscle contraction performed.
Monitoring of the physical properties of the tissues provides valuable information for the clinical diagnosis and evaluation. However, one of the challenges of an ultrasonic method for continuous monitoring of a tissue motion using a conventional clinical ultrasonic image system could be motion artifacts due to the weight and size of its handheld ultrasonic probe employed. A wearable ultrasonic sensor, made of a polyvinylidene fluoride (PVDF) polymer piezoelectric film, may be able to reduce the motion artifacts due to its lightweight and flexible properties. However, the PVDF ultrasonic sensor has a relatively weak transmitting acoustic signal strength which causes poor signal-to-noise ratio of the ultrasonic signal acquired in pulse-echo measurements, particularly for the signal reflected from deeper tissue. This paper investigated an improvement of the ultrasonic performance of the WUS using double-layer PVDF films. The sensor was constructed using two 52-μm thick PVDF films. The developed double-layer WUS showed the 1.7 times greater ultrasonic signal amplitude compared to the WUS made of a single-layer PVDF having the equivalent PVDF film thickness. Thus, the developed double-layer PVDF WUS improved the depth of the ultrasonic penetration into the tissue. The developed WUS successfully demonstrated to monitor the contractions of biceps muscles in an upper arm. In addition, a cardiac tissue motion was clearly observed in the M-mode measurement corresponding with the cardiac cycles obtained from the ECG measurement.
Retinal blood vessel examination is commonly utilized for retinal disease diagnosis by ophthalmologists. The automated retinal vessel segmentation process becomes an essential tool to identify disease. Several retinal vessel segmentation models suffer from a lack of high generalization abilities and low accuracy due to the presence of complex symmetrical and asymmetrical patterns. Robust vessel segmentation of fundus images is needed to improve diagnostic performance including vein occlusion and diabetic retinopathy (DR). In this aspect, this study concentrates on the design of a sandpiper optimization algorithm with region growing based robust retinal blood vessel segmentation (SPORG-RBVS) approach. The proposed SPORG-RBVS technique involves different stages of pre-processing such as grayscale conversion, Z-score-based data normalization, and multi-scale vessel enhancement filtering. The SPO approach addresses the intricate challenges modeled by difficult symmetrical and asymmetrical patterns in retinal vessel segmentation. This method has been specifically designed to improve the generalization capabilities and accuracy of retinal vessel segmentation manners, vital for the precise detection of retinal diseases like vein occlusion and DR. Through phases of preprocessing comprising grayscale conversion, Z-score-based data normalization, and multi-scale vessel enhancement filtering, the SPORG-RBVS model ensures robust segmentation of fundus images. Particularly, the automated segmentation approach employing SPORG incorporates primary seed point generation and threshold determination using the SPO method, contributing to the overall performance of disease detection. A wide-ranging experimental analysis is executed and the outcomes are examined on three benchmark databases such as Digital Retinal Images for Vessel Extraction (DRIVE), Structured Analysis of the Retina (STARE), and CHASE_DB1 (CHASE). The comparative study stated the supremacy of the SPORG-RBVS method over existing techniques with maximum accuracy of 98.68%, 98.14%%, and 98.34% under DRIVE, STARE, and CHASE datasets, respectively.
Mild cognitive impairment (MCI) is the precursor to the advanced stage of Alzheimer’s disease (AD), and it is important to detect the transition to the MCI condition as early as possible. Trends in daily routines/activities provide a measurement of cognitive/functional status, particularly in older adults. In this study, activity data from longitudinal monitoring through in-home ambient sensors are leveraged in predicting the transition to the MCI stage at a future time point. The activity dataset from the Oregon Center for Aging and Technology (ORCATECH) includes measures representing various domains such as walk, sleep, etc. Each sensor-captured activity measure is constructed as a time series, and a variety of summary statistics is computed. The similarity between one individual’s activity time series and that of the remaining individuals is also computed as distance measures. The long short-term memory (LSTM) recurrent neural network is trained with time series statistics and distance measures for the prediction modeling, and performance is evaluated by classification accuracy. The model outcomes are explained using the SHapley Additive exPlanations (SHAP) framework. LSTM model trained using the time series statistics and distance measures outperforms other modeling scenarios, including baseline classifiers, with an overall prediction accuracy of 83.84%. SHAP values reveal that sleep-related features contribute the most to the prediction of the cognitive stage at the future time point, and this aligns with the findings in the literature. Findings from this study not only demonstrate that a practical, less expensive, longitudinal monitoring of older adults’ activity routines can benefit immensely in modeling AD progression but also unveil the most contributing features that are medically applicable and meaningful.
Installing and developing a sophisticated control system to optimize left ventricular assist device (LVAD) pump speed to meet changes in metabolic demand is essential for advancing LVAD technology. This paper aims to design and implement a physiological control method for LVAD pumps to provide optimal cardiac output. The method is designed to adjust the pump speed by regulating the pump flow based on a predefined set point (operating point). The Frank–Starling mechanism technique was adopted to control the set point within a safe operating zone (green square), and it mimics the physiological demand of the patient. This zone is predefined by preload control lines, which are known as preload lines. A proportional–integral (PI) controller was utilized to control the operating point within safe limits to prevent suction or overperfusion. In addition, a PI type 1 fuzzy logic controller was designed and implemented to drive the LVAD pump. To evaluate the design method, rest, moderate, and exercise scenarios of heart failure (HF) were simulated by varying the hemodynamic parameters in one cardiac cycle. This evaluation was conducted using a lumped parameter model of the cardiovascular system (CVS). The results demonstrated that the proposed control method efficiently drives an LVAD pump under accepted clinical conditions. In both scenarios, the left ventricle pressure recorded 112 mmHg for rest and 55 mmHg for exercise, and the systematic flow recorded 5.5 L/min for rest and 1.75 L/min for exercise.