Guillermo Albareda

Guillermo Albareda

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2014 in The European Physical Journal D
Verified
Journal Article
Closed access
PDF file
ABAlbert Benseny
Albert Benseny
GAGuillermo Albareda
Guillermo Albareda
Angel S. SanzAngel S. Sanz
Angel S. Sanz
JMJordi Mompart
Jordi Mompart
Xavier OriolsXavier Oriols
Xavier Oriols

17 February 2009 in Physical Review B
Verified
Journal Article
Open access
PDF file
GAGuillermo Albareda
Guillermo Albareda
Jordi SuñéJordi Suñé
Jordi Suñé
Xavier OriolsXavier Oriols
Xavier Oriols
A many-particle Hamiltonian for a set of particles with Coulomb interaction inside an open system is described without any perturbative or mean-field approximation. The boundary conditions of the Hamiltonian on the borders of the open system [in the real three-dimensional (3D) space representation] are discussed in detail to include the Coulomb interaction between particles inside and outside of the open system. The many-particle Hamiltonian provides the same electrostatic description obtained from the image-charge method, but it has the fundamental advantage that it can be directly implemented into realistic (classical or quantum) electron device simulators via a 3D Poisson solver. Classically, the solution of this many-particle Hamiltonian is obtained via a coupled system of Newton-type equations with a different electric field for each particle. The quantum-mechanical solution of this many-particle Hamiltonian is achieved using the quantum (Bohm) trajectory algorithm [X. Oriols, Phys. Rev. Lett. 98, 066803 (2007)]. The computational viability of the many-particle algorithms to build powerful nanoscale device simulators is explicitly demonstrated for a (classical) double-gate field-effect transistor and a (quantum) resonant tunneling diode. The numerical results are compared with those computed from time-dependent mean-field algorithms showing important quantitative differences.

17 July 2013 in Journal of Computational Electronics
Verified
Journal Article
Closed access
PDF file
GAGuillermo Albareda
Guillermo Albareda
DMD. Marian
D. Marian
ABA. Benali
A. Benali
SYS. Yaro
S. Yaro
NZN. Zanghì
N. Zanghì
Xavier OriolsXavier Oriols
Xavier Oriols

21 August 2014 in Physical Review Letters
Verified
Journal Article
Open access
GAGuillermo Albareda
Guillermo Albareda
HAHeiko Appel
Heiko Appel
IFIgnacio Franco
Ignacio Franco
AAAli Abedi
Ali Abedi
ARAngel Rubio
Angel Rubio
The molecular Schrödinger equation is rewritten in terms of nonunitary equations of motion for the nuclei (or electrons) that depend parametrically on the configuration of an ensemble of generally defined electronic (or nuclear) trajectories. This scheme is exact and does not rely on the tracing out of degrees of freedom. Hence, the use of trajectory-based statistical techniques can be exploited to circumvent the calculation of the computationally demanding Born-Oppenheimer potential-energy surfaces and nonadiabatic coupling elements. The concept of the potential-energy surface is restored by establishing a formal connection with the exact factorization of the full wave function. This connection is used to gain insight from a simplified form of the exact propagation scheme.

2 August 2010 in Physical Review B
Verified
Journal Article
Closed access
GAGuillermo Albareda
Guillermo Albareda
HLHender Lopez
Hender Lopez
XCX. Cartoixà
X. Cartoixà
Jordi SuñéJordi Suñé
Jordi Suñé
Xavier OriolsXavier Oriols
Xavier Oriols
Standard boundary conditions (BCs) for electron-transport simulators are based on specifying the value of the scalar potential (or the electric field) and the charge density at the borders of the simulation box. Due to the computational burden associated to quantum or atomistic descriptions, the use of small simulation boxes that exclude the leads is a mandatory requirement in modern nanoscale simulators. However, if the leads (where screening takes place) are excluded, standard BCs become inaccurate. In this work, we develop analytical expressions for the charge density, the electric field, and the scalar potential along the leads and reservoirs. From these expressions, we present a (time-dependent) BCs algorithm that transfers the specification of the BCs at the boundaries of the simulation box to a deeper position inside the reservoirs. Numerical solutions of the time-dependent Boltzmann equation with our algorithm using large (reservoir, leads, and sample) and small (sample alone) simulation boxes are compared, showing an excellent agreement even at (far from equilibrium) high bias conditions. Numerical results demonstrating the limitations of standard BCs for small simulation boxes are presented. Finally, time-dependent simulations of a resonant tunneling diode (using a quantum trajectory-based simulator) are presented, emphasizing the ability of this BCs algorithm to ensure overall charge neutrality in simulation boxes much smaller than the total lead-sample-lead length. This BCs algorithm requires a minimum computational effort and it can be applied to study dc, ac, and current or voltage fluctuations in nanoscale devices. DOI: http://dx.doi.org/10.1103/PhysRevB.82.085301 © 2010 The American Physical Society

20 May 2013 in Physical Review A
Verified
Journal Article
Open access
FTF. L. Traversa
F. L. Traversa
GAGuillermo Albareda
Guillermo Albareda
MVM. Di Ventra
M. Di Ventra
Xavier OriolsXavier Oriols
Xavier Oriols
We present a protocol for measuring Bohmian, or the mathematically equivalent hydrodynamic, velocities based on an ensemble of two position measurements, defined from a positive operator-valued measure, separated by a finite time interval. The protocol is very accurate and robust as long as the first measurement uncertainty divided by the finite time interval between measurements is much larger than the Bohmian velocity, and the system evolves under flat potential between measurements. The difference between the Bohmian velocity of the unperturbed state and the measured one is predicted to be much smaller than $1%$ in a large range of parameters. Counterintuitively, the measured velocity is that at the final time and not a time-averaged value between measurements.