Alvaro Hoffer

Dr. Alvaro Hoffer

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2020 in IEEE Access
Verified
Journal Article
Open access
AHAlvaro Hoffer
Alvaro Hoffer
IPIlya Petrov
Ilya Petrov
JPJuha J. Pyrhonen
Juha J. Pyrhonen
JTJuan A. Tapia
Juan A. Tapia
GBGerd Bramerdorfer
Gerd Bramerdorfer
This paper presents an analysis of a permanent magnet synchronous machine (PMSM) with an unequal teeth width. The use of the concentrated nonoverlapping winding, also known as tooth-coil winding, has certain advantages. In addition, asymmetric features can be exploited by adopting this winding configuration to improve the machine performance. The procedure involves increasing the stator tooth width and, to the same extent, reducing the adjacent stator tooth width. In this paper, an analytical method was employed to predict and understand the back-EMF behavior, and a finite element analysis (FEA) was performed to verify the analytical method. Furthermore, a detailed study of the machine performance (electromagnetic torque, flux density, and losses) was carried out by the FEA. The machine was built and tested to validate the performance of the machine.

29 March 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
AHAlvaro Hoffer
Alvaro Hoffer
RMRoberto H. Moncada
Roberto H. Moncada
BPBoris J. Pavez-Lazo
Boris J. Pavez-Lazo
JTJuan Tapia
Juan Tapia
LLLasse Laurila
Lasse Laurila
This article proposes a simple method to calculate a current vector trajectory for the enhanced operation of the electric power generation system based on a synchronous reluctance machine (SynRM). Owing to magnetic saturation and cross magnetization, the performance and the torque capability of a SynRM vary according to the position and the value of the stator current. State-of-the-art control methods usually assume parameters with constant values, especially the inductance, neglecting saturation, leading to possible uncertainty in the machine operation. Therefore, a current vector trajectory to operate this type of machine, as a generator, in an extended speed range, with enhanced performance and considering magnetic saturation is proposed. A straightforward algorithm based on the inductance characteristic of the machine is used to calculate the trajectory of the stator current vector. This trajectory is evaluated via the numerical simulation of an experimentally validated finite-element model of a SynRM. The results show that the proposed current vector trajectory can improve the torque capability to 5% concerning the estimated trajectory without considering saturation. Experimental results are also provided to demonstrate the enhanced operation of the generator.

10 February 2021 in IEEE Access
Verified
Journal Article
Open access
AHAlvaro Hoffer
Alvaro Hoffer
IPIlya Petrov
Ilya Petrov
JPJuha J. Pyrhonen
Juha J. Pyrhonen
JTJuan Tapia
Juan Tapia
A fully submersible permanent magnet synchronous machine (PMSM) is introduced in this paper. Underwater operation requires that the machine parts have to be resistant to corrosion, and the electrically conducting parts need to be properly insulated from water. The machine under study consists of a rotor-surface permanent magnet rotor, protected by a glass-fiber-reinforced plastic (GFRP) cover, and a fully stainless stator. The novelty of the machine is found in the design and special materials used in the manufacture. The stator core is made of ferritic stainless steel laminations, and the selected winding material is polyvinyl chloride (PVC) insulated copper wire. An extra low-speed, stainless-core submersible PMSM was constructed and tested. To simplify the machine construction, a tooth-coil single-layer winding was adopted. An asymmetric stator design was selected to enhance the machine performance. The performance of the 1.7 kW, 80 r/min machine was analyzed by finite element analysis (FEA) and validated by experimental tests, where despite a very low rotational speed, 74% efficiency was reached at the target load point. The PMSM was found to be fully functional for the application.

24 February 2025 in Processes
Verified
Journal Article
Open access
PDF file
CAClaudio Alarcon
Claudio Alarcon
SASofia Alarcon
Sofia Alarcon
AHAlvaro Hoffer
Alvaro Hoffer
BPBoris Pavez
Boris Pavez
Green hydrogen is a promising energy vector for industrial applications. However, hydrogen leaks can occur causing greenhouse effects and posing safety risks for operators and local communities, potentially leading to legal liabilities. Industry 4.0 focuses on digital industrial modernization, while Industry 5.0 emphasizes collaborative, human-centered, and sustainable processes. This study developed and analyzed an Industry 5.0 proof of concept as an additional safety layer for hydrogen leak management. The proof of concept was implemented using Raspberry Pi microcomputers, integrated computer vision, and OpenAI GPT-3 for dynamic email communication. A legal liability analysis for Chile and Spain identified potential challenges in transitioning the system into a market-ready product. The findings suggest the system should act as a complementary safety layer rather than a primary detection system to mitigate legal liability risks, as operational deployment without full certification and validation could lead to malfunctions. This study illustrated how hydrogen detection and management can be integrated into Industry 5.0 smart systems. With growing global interest in sustainable engineering and AI regulation, as reflected in Regulation (EU) 2024/1689, legal considerations over technologies like the one presented in this study are becoming increasingly relevant.

20 November 2023 in IEEE Access
Verified
Journal Article
Open access
RVRodrigo J. Villalobos
Rodrigo J. Villalobos
LMLuis A. Moran
Luis A. Moran
MIMauricio Inostroza
Mauricio Inostroza
AHAlvaro Hoffer
Alvaro Hoffer
CPCristian Pesce
Cristian Pesce
FHFernando Huenupan
Fernando Huenupan
Measuring the leakage current and voltage of an insulator is widely used to calculate indices for the pollution estimation of overhead line insulator strings. These indices are intended to be used for the online condition monitoring of insulators to prevent flashover failure. When these indices are used in real time, uncertain results are observed because of the variability of the data over time. In order to improve the performance of the indices, this study focuses on the analysis of the leakage current and its harmonics over a time dimension to show the amplitude changes and their causes. For this purpose, the concept of harmonic impedance for insulators was introduced. In an artificial fog chamber, a U120B insulator is subjected to several tests with different levels of contamination and at different levels of constant humidity. The results showed that the equivalent impedance of the insulator varied significantly over time (up to four times). This variation is due to the water absorption process captured by the insulator, and depends on the level of contamination and humidity. Both the 5th and 7th order harmonic impedances are stable over time, with exceptional variations of less than 9%; therefore, harmonic currents depend only on the voltage harmonics. In contrast, the 3rd and 9th order harmonic impedances exhibited amplitude variations of up to 9.1 times. Finally, several indices are evaluated. The phase difference angle (PD) index showed the best performance at a constant humidity and steady-state leakage current.

7 January 2026 in Results in Engineering
Verified
Journal Article
Open access
HMHanieh Molaie
Hanieh Molaie
AKAbdollah Kavousi-Fard
Abdollah Kavousi-Fard
MDMoslem Dehghani
Moslem Dehghani
MSMorteza Sheikh
Morteza Sheikh
AHAlvaro Hoffer
Alvaro Hoffer
JRJose Rodriguez
Jose Rodriguez