This article describes tests investigating a feasible source of passive damping for post-tensioned glue-laminated (glulam) timber structures. This innovative structural system adapts precast concrete PRESSS technology [Priestley et al., 1999] to engineered wood products combining the use of post-tensioned tendons with large timber members. Current testing is aimed at further improvement of the system through additional energy dissipation. Testing has favorably compared glue-laminated timber (not previously implemented in this way) with laminated veneer lumber (LVL) used in New Zealand. After initial benchmark testing with post-tensioning only, a simple, minimally invasive and replaceable type of hysteretic damper was added.
28 March 2017 in Bulletin of Earthquake Engineering
The seismic performance of existing RC frame buildings seismically retrofitted by base isolation is examined. Two different types of isolation systems are considered, i.e.: rubber-based and friction-based isolation systems, respectively. Two different performance levels are examined, namely: Global collapse prevention and Usability preventing damage. Seismic performance is assessed by multi-stripe nonlinear time-history analysis, considering earthquake intensity levels with return period ranging from 10 to 100000 years. Results point out that seismic isolation works effectively in limiting damage well beyond the design limit state level while it shows a limited margin with respect to collapse beyond the design limit state level.
16 October 2018 in Journal of Earthquake Engineering
This paper reports on results of nonlinear analyses performed within the RINTC project on an RC building isolated with different systems (High Damping Rubber Bearings, High Damping Rubber Bearings and Flat Sliding Bearings, Friction Pendulum System) and designed according to the Italian design code. The seismic response has been evaluated under different seismic input levels of two sites with different hazard and by considering two Limit States: Global Collapse and Usability-Preventing Damage. The influence of seismic stoppers and modelling uncertainties is also evaluated. Results permit to compute the implicit collapse risk and to identify critical aspects of current design procedures.
This paper presents a design procedure to evaluate the mechanical characteristics of hysteretic Energy Dissipation Bracing (EDB) systems for seismic retrofitting of existing reinforced concrete framed buildings. The proposed procedure, aiming at controlling the maximum interstorey drifts, imposes a maximum top displacement as function of the seismic demand and, if needed, regularizes the stiffness and strength of the building along its elevation. In order to explain the application of the proposed procedure and its capacity to involve most of the devices in the energy dissipation with similar level of ductility demand, a simple benchmark structure has been studied and nonlinear dynamic analyses have been performed. A further goal of this work is to propose a simplified approach for designing dissipating systems based on linear analysis with the application of a suitable behaviour factor, in order to achieve a widespread adoption of the passive control techniques. At this goal, the increasing of the structural performances due to the addition of an EDB system designed with the above-mentioned procedure has been estimated considering one thousand case studies designed with different combinations of the main design parameters. An analytical formulation of the behaviour factor for braced buildings has been proposed.