Objectives: Contrast-enhanced (CE) magnetic resonance imaging (MRI) is the most effective imaging modality for breast cancer detection. A contrast agent–free examination technique would be desirable for breast MRI screening. The purpose of this study was to evaluate the capability to detect and characterize suspicious breast lesions with an abbreviated, non–contrast-enhanced MRI protocol featuring ultra-high b-value diffusion-weighted imaging (DWI) compared with CE images. Materials and Methods: The institutional review board–approved prospective study included 127 female subjects with different clinical indications for breast MRI. Magnetic resonance imaging examinations included DWI sequences with b-values of 1500 s/mm2 (b1500) and 2500 s/mm2 (b2500), native T1- and T2-weighted images, and CE sequences at 1.5 T and 3 T scanners. Two reading rounds were performed, including either the b1500 or the b2500 DWI in consecutive assessment steps: (A) maximum intensity projections (MIPs) of DWI, (B) DWI and apparent diffusion coefficient maps, (C) as (B) but with additional native T1- and T2-weighted images, and (D) as (C) but with additional CE images (full-length protocol). Two readers independently determined the presence of a suspicious lesion. Histological confirmation was obtained for conspicuous lesions, whereas the full MRI data set was obtained for inconspicuous and clearly benign lesions. Statistical analysis included calculation of diagnostic accuracy and interrater agreement via the intraclass correlation coefficient. Results: The cohort comprised 116 cases with BI-RADS 1 findings and 138 cases with BI-RADS ≥2 findings, including 38 histologically confirmed malignancies. For (A), breasts without pathological findings could be recognized with high diagnostic accuracy (negative predictive value, ≥97.0%; sensitivity, ≥92.1% for both readers), but with a limited specificity (≥58.3%; positive predictive value, ≥28.6%). Within the native readings, approach (C) with b2500 performed best (negative predictive value, 99.5%; sensitivity, 97.4%; specificity, 88.4%). The intraclass correlation coefficient was between 0.683 (MIP b1500) and 0.996 (full protocol). Conclusions: A native abbreviated breast MRI protocol with advanced high b-value DWI might allow nearly equivalent diagnostic accuracy as CE breast MRI and seems to be well suited for lesion detection purposes.
The primary objective of the study was to compare a spiral breast computed tomography system (SBCT) to digital breast tomosynthesis (DBT) for the detection of microcalcifications (MCs) in breast specimens. The secondary objective was to compare various reconstruction modes in SBCT. In total, 54 breast biopsy specimens were examined with mammography as a standard reference, with DBT, and with a dedicated SBCT containing a photon-counting detector. Three different reconstruction modes were applied for SBCT datasets (Recon1 = voxel size (0.15 mm)3, smooth kernel; Recon2 = voxel size (0.05 mm)3, smooth kernel; Recon3 = voxel size (0.05 mm)3, sharp kernel). Sensitivity and specificity of DBT and SBCT for the detection of suspicious MCs were analyzed, and the McNemar test was used for comparisons. Diagnostic confidence of the two readers (Likert Scale 1 = not confident; 5 = completely confident) was analyzed with ANOVA. Regarding detection of MCs, reader 1 had a higher sensitivity for DBT (94.3%) and Recon2 (94.9%) compared to Recon1 (88.5%; p < 0.05), while sensitivity for Recon3 was 92.4%. Respectively, reader 2 had a higher sensitivity for DBT (93.0%), Recon2 (92.4%), and Recon3 (93.0%) compared to Recon1 (86.0%; p < 0.05). Specificities ranged from 84.7–94.9% for both readers (p > 0.05). The diagnostic confidence of reader 1 was better with SBCT than with DBT (DBT 4.48 ± 0.88, Recon1 4.77 ± 0.66, Recon2 4.89 ± 0.44, and Recon3 4.75 ± 0.72; DBT vs. Recon1/2/3: p < 0.05), while reader 2 found no differences. Sensitivity and specificity for the detection of MCs in breast specimens is equal for DBT and SBCT when a small voxel size of (0.05 mm)3 is used with an equal or better diagnostic confidence for SBCT compared to DBT.
Besides X-ray and fluoroscopy, a previously introduced X-ray scanner offers a 3D cone beam option (Multitom Rax, Siemens Healthcare). The aim of this study was to evaluate various scan parameters and post-processing steps to optimize image quality and radiation exposure for imaging of the parasinus region. Four human cadaver heads were examined with different tube voltages (90–121 kV), dose levels (DLs) (278–2180 nGy) and pre-filtration methods (none, Cu 0.2 mm, Cu 0.3 mm and Sn 0.4 mm). All images were reconstructed in 2 mm slice thickness with and without a metal artifact reduction algorithm in three different kernels. In total, 80 different scan protocols and 480 datasets were evaluated. Image quality was rated on a 5-point Likert scale. Radiation exposure (mean computed tomography volume index (CTDIvol) and effective dose) was calculated for each scan. The most dose-effective combination for the diagnosis of sinusitis was 121 kV/DL of 278/0.3 mm copper (CTDIvol 1.70 mGy, effective dose 77 µSv). Scan protocols with 121 kV/DL1090/0.3 mm copper were rated sufficient for preoperative sinus surgery planning (CTDIvol 4.66 mGy, effective dose 212 µSv). Therefore, sinusitis and preoperative sinus surgery planning can be performed in diagnostic image quality at low radiation dose levels with a multipurpose X-ray system.