Frederik Bernd Laun

Dr. Frederik Bernd Laun

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
JHJannis Hanspach
Jannis Hanspach
ANArmin M. Nagel
Armin M. Nagel
BHBernhard Hensel
Bernhard Hensel
MUMichael Uder
Michael Uder
LKLeon Koros
Leon Koros
FLFrederik Bernd Laun
Frederik Bernd Laun
Purpose: To investigate and to provide guidance for sample size selection based on the current practice in MR technical development studies in which healthy volunteers are examined.Methods: All original articles published in Magnetic Resonance in Medicine between 2017 and 2019 were investigated and categorized according to technique, anatomical region, and magnetic field strength. The number of examined healthy volunteers (ie, the sample size) was collected and evaluated, whereas the number of patients was not considered. Papers solely measuring patients, animals, phantoms, specimens, or studies using existing data, for example, from an open databank, or consisting only of theoretical work or simulations were excluded.Results: The median sample size of the 882 included studies was 6. There were some peaks in the sample size distribution (eg, 1, 5, and 10). In 49.9%, 82.1%, and 95.6% of the studies, the sample size was smaller or equal to 5, 10, and 20, respectively.Conclusion: We observed a large variance in sample sizes reflecting the variety of studies published in Magnetic Resonance in Medicine. Therefore, it can be concluded that it is current practice to balance the need for statistical power with the demand to minimize experiments involving healthy humans, often by choosing small sample sizes between 1 and 10. Naturally, this observation does not release an investigator from ensuring that sufficient data are acquired to reach statistical conclusions.

19 April 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ALAndrzej Liebert
Andrzej Liebert
MZMoritz Zaiss
Moritz Zaiss
RGRene Gumbrecht
Rene Gumbrecht
KTKatharina Tkotz
Katharina Tkotz
PLPeter Linz
Peter Linz
ANArmin M. Nagel
Armin M. Nagel

17 March 2022 in NMR in Biomedicine
Verified
Journal Article
Open access
AMAngelika Mennecke
Angelika Mennecke
KKKatrin M. Khakzar
Katrin M. Khakzar
AGAlexander German
Alexander German
KHKai Herz
Kai Herz
MFMoritz S. Fabian
Moritz S. Fabian
MZMoritz Zaiss
Moritz Zaiss
The objective of the current study was to optimize the postprocessing pipeline of 7 T chemical exchange saturation transfer (CEST) imaging for reproducibility and to prove this optimization for the detection of age differences and differences between patients with Parkinson's disease versus normal subjects. The following 7 T CEST MRI experiments were analyzed: repeated measurements of a healthy subject, subjects of two age cohorts (14 older, seven younger subjects), and measurements of 12 patients with Parkinson's disease. A slab‐selective, ‐homogeneous parallel transmit protocol was used. The postprocessing, consisting of motion correction, smoothing, ‐correction, normalization, denoising, ‐correction and Lorentzian fitting, was optimized regarding the intrasubject and intersubject coefficient of variation (CoV) of the amplitudes of the amide pool and the aliphatic relayed nuclear Overhauser effect (rNOE) pool within the brain. Seven “tricks” for postprocessing accomplished an improvement of the mean voxel CoV of the amide pool and the aliphatic rNOE pool amplitudes of less than 5% and 3%, respectively. These postprocessing steps are: motion correction with interpolation of the motion of low‐signal offsets (1) using the amide pool frequency offset image as reference (2), normalization of the Z‐spectrum using the outermost saturated measurements (3), correction of the Z‐spectrum with moderate spline smoothing (4), denoising using principal component analysis preserving the 11 highest intensity components (5), correction using a linear fit (6) and Lorentzian fitting using the five‐pool fit model (7). With the optimized postprocessing pipeline, a significant age effect in the amide pool can be detected. Additionally, for the first time, an aliphatic rNOE contrast between subjects with Parkinson's disease and age‐matched healthy controls in the substantia nigra is detected. We propose an optimized postprocessing pipeline for CEST multipool evaluation. It is shown that by the use of these seven “tricks”, the reproducibility and, thus, the statistical power of a CEST measurement, can be greatly improved and subtle changes can be detected.

1 February 2020 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Closed access
JMJan Martin
Jan Martin
SESebastian Endt
Sebastian Endt
AWAndreas Wetscherek
Andreas Wetscherek
TKTristan Anselm Kuder
Tristan Anselm Kuder
ADArnd Doerfler
Arnd Doerfler
FLFrederik Bernd Laun
Frederik Bernd Laun

1 April 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
ARAndreas Riexinger
Andreas Riexinger
JMJan Martin
Jan Martin
AWAndreas Wetscherek
Andreas Wetscherek
TKTristan Anselm Kuder
Tristan Anselm Kuder
MUMichael Uder
Michael Uder
FLFrederik Bernd Laun
Frederik Bernd Laun
Purpose To find an optimized b-value distribution for reproducible triexponential intravoxel incoherent motion (IVIM) exams in the liver. Methods A numeric optimization of b-value distributions was performed using the triexponential IVIM equation and 27 different IVIM parameter sets. Starting with an initially optimized distribution of 6 b-values, the number of b-values was increased stepwise. Each new b-value was chosen from a set of 64 predefined b-values based on the computed summed relative mean error of the fitted triexponential IVIM parameters. This process was repeated for up to 100 b-values. In simulations and in vivo measurements, optimized b-value distributions were compared to 4 representative distributions found in literature. Results The first 16 optimized b-values were 0, 0.3, 0.3, 70, 200, 800, 70, 1, 3.5, 5, 70, 1.2, 6, 45, 1.5, and 60 in units of s/mm(2). Low b-values were much more frequent than high b-values. The optimized b-value distribution resulted in a higher fit stability compared to distributions used in literature in both, simulation and in vivo measurements. Using more than 6 b-values, ideally 16 or more, increased the fit stability considerably. Conclusion Using optimized b-values, the fit uncertainty in triexponential IVIM can be largely reduced. Ideally, 16 or more b-values should be acquired.

1 November 2019 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
TPTheresa Palm
Theresa Palm
EWEvelyn Wenkel
Evelyn Wenkel
SOSabine Ohlmeyer
Sabine Ohlmeyer
RJRolf Janka
Rolf Janka
MUMichael Uder
Michael Uder
FLFrederik Bernd Laun
Frederik Bernd Laun