We have developed a dual-modality CT/SPECT imaging system for small-animal imaging applications. The X-ray system comprises a commercially available micro-focus X-ray tube and a CCD-based X-ray camera. X-ray transmission measurements are performed based on cone-beam geometry. Individual projections are acquired by rotating the animal about a vertical axis in front of the CCD detector. A high-resolution CT image is obtained after reconstruction using an ordered subsets-expectation maximization (OS-EM) reconstruction algorithm. The SPECT system utilizes a compact semiconductor camera module previously developed in our group. The module is mounted perpendicular to the X-ray tube/CCD combination. It consists of a 64 /spl times/ 64 pixellated CdZnTe detector and a parallel-hole tungsten collimator. The field of view is 1 square inch. Planar projections for SPECT reconstruction are obtained by rotating the animal in front of the detector. Gamma-ray and X-ray images are presented of phantoms and mice. Procedures for merging the anatomical and functional images are discussed.
1 November 2010 in American Journal of Respiratory and Critical Care Medicine
Rationale: Resistive breathing is associated with large negative intrathoracic pressures. Increased mechanical stress induces high-permeability pulmonary edema and lung inflammation. Objectives: To determine the effects of resistive breathing on the healthy lung. Methods: Anesthetized rats breathed through a two-way nonrebreathing valve. The inspiratory line was connected to a resistance setting peak inspiratory tracheal pressure at 50% of maximum (inspiratory resistive breathing), while 100% oxygen was supplied to prevent hypoxemia. Quietly breathing animals (100% oxygen) served as controls. Lung injury was evaluated after 3 and 6 hours of resistive breathing. Measurements and Main Results: After both 3 and 6 hours of resistive breathing, lung permeability was increased, as assessed by 99mTc-diethylenetriaminepentaacetic acid scintigraphy and Evans blue dye extravasation. Tissue elasticity, measured on the basis of static pressure–volume curves and by the low-frequency forced oscillation technique, was also increased. After both 3 and 6 hours of resistive breathing, gravimetric measurements revealed the presence of pulmonary edema and analysis of bronchoalveolar lavage showed increased total protein content, whereas the total cell count was elevated only after 6 hours of resistive breathing. Cytokine levels were assessed in bronchoalveolar lavage fluid and lung tissue by ELISA and were increased after 6 hours compared with controls. Western blot analysis showed early activation of Src kinase via phosphorylation (at 30 min), and Erk1/2 and IκBα (nuclear factor-κB inhibitor) were phosphorylated at 3 and 6 hours. Pathology revealed the presence of lung injury after resistive breathing. Conclusions: Resistive breathing induces acute lung injury and inflammation.
5 August 2020 in Journal of The Royal Society Interface
We introduce a novel methodology for predicting the time evolution of the number of individuals in a given country reported to be infected with SARS-CoV-2. This methodology, which is based on the synergy of explicit mathematical formulae and deep learning networks, yields algorithms whose input is only the existing data in the given country of the accumulative number of individuals who are reported to be infected. The analytical formulae involve several constant parameters that were determined from the available data using an error-minimizing algorithm. The same data were also used for the training of a bidirectional long short-term memory network. We applied the above methodology to the epidemics in Italy, Spain, France, Germany, USA and Sweden. The significance of these results for evaluating the impact of easing the lockdown measures is discussed.
18 February 2022 in Biomedical Physics & Engineering Express
Over the past few years, positron emission tomography/computed tomography (PET/CT) imaging for computer-aided diagnosis has received increasing attention. Supervised deep learning architectures are usually employed for the detection of abnormalities, with anatomical localization, especially in the case of CT scans. However, the main limitations of the supervised learning paradigm include (i) large amounts of data required for model training, and (ii) the assumption of fixed network weights upon training completion, implying that the performance of the model cannot be further improved after training. In order to overcome these limitations, we apply a few-shot learning (FSL) scheme. Contrary to traditional deep learning practices, in FSL the model is provided with less data during training. The model then utilizes end-user feedback after training to constantly improve its performance. We integrate FSL in a U-Net architecture for lung cancer lesion segmentation on PET/CT scans, allowing for dynamic model weight fine-tuning and resulting in an online supervised learning scheme. Constant online readjustments of the model weights according to the users’ feedback, increase the detection and classification accuracy, especially in cases where low detection performance is encountered. Our proposed method is validated on the Lung-PET-CT-DX TCIA database. PET/CT scans from 87 patients were included in the dataset and were acquired 60 minutes after intravenous 18 F-FDG injection. Experimental results indicate the superiority of our approach compared to other state-of-the-art methods.
1 May 2002 in IEEE Transactions on Medical Imaging
Imaging is often used for the purpose of estimating the value of some parameter of interest. For example, a cardiologist may measure the ejection fraction (EF) of the heart in order to know how much blood is being pumped out of the heart on each stroke. In clinical practice, however, it is difficult to evaluate an estimation method because the gold standard is not known, e.g., a cardiologist does not know the true EF of a patient. Thus, researchers have often evaluated an estimation method by plotting its results against the results of another (more accepted) estimation method, which amounts to using one set of estimates as the pseudogold standard. In this paper, we present a maximum-likelihood approach for evaluating and comparing different estimation methods without the use of a gold standard with specific emphasis on the problem of evaluating EF estimation methods. Results of numerous simulation studies will be presented and indicate that the method can precisely and accurately estimate the parameters of a regression line without a gold standard, i.e., without the x axis.