Nikolaos Dikaios

Dr. Nikolaos Dikaios

Mathematics, Academy of Athens, Athens, Attikí, Greece
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2012 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
KTKris Thielemans
Kris Thielemans
CTCharalampos Tsoumpas
Charalampos Tsoumpas
SMSanida Mustafovic
Sanida Mustafovic
TBTobias Beisel
Tobias Beisel
PAPablo Aguiar
Pablo Aguiar
MJMatthew W Jacobson
Matthew W Jacobson
We present a new version of STIR (Software for Tomographic Image Reconstruction), an open source object-oriented library implemented in C++ for 3D positron emission tomography reconstruction. This library has been designed such that it can be used for many algorithms and scanner geometries, while being portable to various computing platforms. This second release enhances its flexibility and modular design and includes additional features such as Compton scatter simulation, an additional iterative reconstruction algorithm and parametric image reconstruction (both indirect and direct). We discuss the new features in this release and present example results. STIR can be downloaded from http://stir.sourceforge.net.

1 April 2015 in Investigative Radiology
Verified
Journal Article
Closed access
EPEleftheria Panagiotaki
Eleftheria Panagiotaki
RCRachel W. Chan
Rachel W. Chan
Nikolaos DikaiosNikolaos Dikaios
Nikolaos Dikaios
HAHashim U. PhD Ahmed
Hashim U. PhD Ahmed
JOJames Msc O’callaghan
James Msc O’callaghan
DADaniel C. Alexander
Daniel C. Alexander
Objective The aim of this study was to demonstrate the feasibility of the recently introduced Vascular, Extracellular, and Restricted Diffusion for Cytometry in Tumours (VERDICT) framework for imaging prostate cancer with diffusion-weighted magnetic resonance imaging (DW-MRI) within a clinical setting. Materials and Methods The VERDICT framework is a noninvasive microstructure imaging technique that combines an in-depth diffusion MRI acquisition with a mathematical model to estimate and map microstructural tissue parameters such as cell size and density and vascular perfusion. In total, 8 patients underwent 3-T MRI using 9 different b values (100–3000 s/mm2). All patients were imaged before undergoing biopsy. Experiments with VERDICT analyzed DW-MRI data from patients with histologically confirmed prostate cancer in areas of cancerous and benign peripheral zone tissue. For comparison, we also fitted commonly used diffusion models such as the apparent diffusion coefficient (ADC), the intravoxel incoherent motion (IVIM), and the kurtosis model. We also investigated correlations of ADC and kurtosis with VERDICT parameters to gain some biophysical insight into the various parameter values. Results Eight patients had prostate cancer in the peripheral zone, with Gleason score 3 + 3 (n = 1), 3 + 4 (n = 6), and 4 + 3 (n = 1). The VERDICT model identified a significant increase in the intracellular and vascular volume fraction estimates in cancerous compared with benign peripheral zone, as well as a significant decrease in the volume of the extracellular-extravascular space (EES) (P = 0.05). This is in agreement with manual segmentation of the biopsies for prostate tissue component analysis, which found proliferation of epithelium, loss of surrounding stroma, and an increase in vasculature. The standard ADC and kurtosis parameters were also significantly different (P = 0.05) between tissue types. There was no significant difference in any of the IVIM parameters (P = 0.11 to 0.29). The VERDICT parametric maps from voxel-by-voxel fitting clearly differentiated cancer from benign regions. Kurtosis and ADC parameters correlated most strongly with VERDICT’s intracellular volume fraction but also moderately with the EES and vascular fractions. Conclusions The VERDICT model distinguished tumor from benign areas, while revealing differences in microstructure descriptors such as cellular, vascular, and EES fractions. The parameters of ADC and kurtosis models also discriminated between cancer and benign regions. However, VERDICT provides more specific information that disentangles the various microstructural features underlying the changes in ADC and kurtosis. These results highlight the clinical potential of the VERDICT framework and motivate the construction of a shorter, clinically viable imaging protocol to enable larger trials leading to widespread translation of the method.

30 April 2014 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
BTBenjamin Tremoulheac
Benjamin Tremoulheac
Nikolaos DikaiosNikolaos Dikaios
Nikolaos Dikaios
DADavid Atkinson
David Atkinson
SASimon R. Arridge
Simon R. Arridge
Dynamic magnetic resonance imaging (MRI) is used in multiple clinical applications, but can still benefit from higher spatial or temporal resolution. A dynamic MR image reconstruction method from partial ( k, t)-space measurements is introduced that recovers and inherently separates the information in the dynamic scene. The reconstruction model is based on a low-rank plus sparse decomposition prior, which is related to robust principal component analysis. An algorithm is proposed to solve the convex optimization problem based on an alternating direction method of multipliers. The method is validated with numerical phantom simulations and cardiac MRI data against state of the art dynamic MRI reconstruction methods. Results suggest that using the proposed approach as a means of regularizing the inverse problem remains competitive with state of the art reconstruction techniques. Additionally, the decomposition induced by the reconstruction is shown to help in the context of motion estimation in dynamic contrast enhanced MRI.

12 September 2013 in European Radiology
Verified
Journal Article
Closed access
PDF file
JMJesica C. Makanyanga
Jesica C. Makanyanga
DPDoug Pendsé
Doug Pendsé
Nikolaos DikaiosNikolaos Dikaios
Nikolaos Dikaios
SBStuart Bloom
Stuart Bloom
SMSara McCartney
Sara McCartney
STStuart A. Taylor
Stuart A. Taylor

1 February 2014 in Medical Image Analysis
Verified
Journal Article
Open access
VHValentin Hamy
Valentin Hamy
Nikolaos DikaiosNikolaos Dikaios
Nikolaos Dikaios
SPShonit Punwani
Shonit Punwani
AMAndrew Melbourne
Andrew Melbourne
ALArash Latifoltojar
Arash Latifoltojar
DADavid Atkinson
David Atkinson
Motion correction in Dynamic Contrast Enhanced (DCE-) MRI is challenging because rapid intensity changes can compromise common (intensity based) registration algorithms. In this study we introduce a novel registration technique based on robust principal component analysis (RPCA) to decompose a given time-series into a low rank and a sparse component. This allows robust separation of motion components that can be registered, from intensity variations that are left unchanged. This Robust Data Decomposition Registration (RDDR) is demonstrated on both simulated and a wide range of clinical data. Robustness to different types of motion and breathing choices during acquisition is demonstrated for a variety of imaged organs including liver, small bowel and prostate. The analysis of clinically relevant regions of interest showed both a decrease of error (15-62% reduction following registration) in tissue time-intensity curves and improved areas under the curve (AUC60) at early enhancement.

29 December 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
Giorgos PapanastasiouGiorgos Papanastasiou
Giorgos Papanastasiou
Nikolaos DikaiosNikolaos Dikaios
Nikolaos Dikaios
JHJiahao Huang
Jiahao Huang
CWChengjia Wang
Chengjia Wang
Guang YangGuang Yang
Guang Yang
Medical imaging is a key component in clinical diagnosis, treatment planning and clinical trial design, accounting for almost 90% of all healthcare data. CNNs achieved performance gains in medical image analysis (MIA) over the last years. CNNs can efficiently model local pixel interactions and be trained on small-scale MI data. Despite their important advances, typical CNN have relatively limited capabilities in modelling “global” pixel interactions, which restricts their generalisation ability to understand out-of-distribution data with different “global” information. The recent progress of Artificial Intelligence gave rise to Transformers, which can learn global relationships from data. However, full Transformer models need to be trained on large-scale data and involve tremendous computational complexity. Attention and Transformer compartments (“Transf/Attention”) which can well maintain properties for modelling global relationships, have been proposed as lighter alternatives of full Transformers. Recently, there is an increasing trend to co-pollinate complementary local-global properties from CNN and Transf/Attention architectures, which led to a new era of hybrid models. The past years have witnessed substantial growth in hybrid CNN-Transf/Attention models across diverse MIA problems. In this systematic review, we survey existing hybrid CNN-Transf/Attention models, review and unravel key architectural designs, analyse breakthroughs, and evaluate current and future opportunities as well as challenges. We also introduced an analysis framework on generalisation opportunities of scientific and clinical impact, based on which new data-driven domain generalisation and adaptation methods can be stimulated.