Jann Harberts

Dr. Jann Harberts

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2024 in Advanced Materials
Verified
Journal Article
Closed access
MDMuamer Dervisevic
Muamer Dervisevic
JHJann Harberts
Jann Harberts
RSRaquel Sánchez‐Salcedo
Raquel Sánchez‐Salcedo
NVNicolas Voelcker
Nicolas Voelcker

7 April 2020 in Biomaterials Science
Verified
Journal Article
Closed access
PDF file
JHJann Harberts
Jann Harberts
UHUndine Haferkamp
Undine Haferkamp
SHStefanie Haugg
Stefanie Haugg
CFCornelius Fendler
Cornelius Fendler
DLDennis Lam
Dennis Lam
RBRobert H. Blick
Robert H. Blick
Nanostructured substrates such as nanowire arrays form a powerful tool for building next-generation medical devices.

22 September 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JHJann Harberts
Jann Harberts
MSMalte Siegmund
Malte Siegmund
MSMatteo Schnelle
Matteo Schnelle
TZTing Zhang
Ting Zhang
YLYakui Lei
Yakui Lei
RBRobert H. Blick
Robert H. Blick
Nanostructured cell culture substrates featuring nanowire (NW) arrays have been applied to a variety of basic cell lines and rodent neurons to investigate cellular behavior or to stimulate cell responses. However, patient-derived human neurons—a prerequisite for studying e.g. neurodegenerative diseases efficiently—are rarely employed due to sensitive cell culture protocols and usually long culturing periods. Here, we present human patient induced pluripotent stem cell-derived neurons cultured on densely-spaced spiky silicon NW arrays (600 NWs/ 100 µm $$^2$$ 2 with NW lengths of 1 µm) which show mature electrophysiological characteristics after only 20 days of culturing. Exemplary neuronal growth and network formation on the NW arrays are demonstrated using scanning electron microscopy and immunofluorescence microscopy. The cells and neurites rest in a fakir-like settling state on the NWs only in contact with the very NW tips shown by cross-sectional imaging of the cell/NW interface using focused ion beam milling and confocal laser scanning microscopy. Furthermore, the NW arrays promote the cell culture by slightly increasing the share of differentiated neurons determined by the quantification of immunofluorescence microscopy images. The electrophysiological functionality of the neurons is confirmed with patch-clamp recordings showing the excellent capability to fire action potentials. We believe that the short culturing time to obtain functional human neurons generated from patient-derived neural progenitor cells and the robustness of this differentiation protocol to produce these neurons on densely-spaced spiky nanowire arrays open up new pathways for stem cell characterization and neurodegenerative disease studies.

14 July 2020 in Nanoscale Advances
Verified
Journal Article
Open access
PDF file
CFCornelius Fendler
Cornelius Fendler
JHJann Harberts
Jann Harberts
LRLars Rafeldt
Lars Rafeldt
GLGabriele Loers
Gabriele Loers
Robert ZieroldRobert Zierold
Robert Zierold
RBRobert H. Blick
Robert H. Blick
Tailor-made structures of micron-sized steps and grooves serve as cell culture platforms to guide neurite outgrowth. The effects of contact guidance through topography and chemical guidance are analyzed.

29 November 2021 in Nanoscale
Verified
Journal Article
Open access
PDF file
JHJann Harberts
Jann Harberts
KBKatja Bours
Katja Bours
MSMalte Siegmund
Malte Siegmund
CHCarina Hedrich
Carina Hedrich
MGMichael Glatza
Michael Glatza
RBRobert H. Blick
Robert H. Blick
We tested the growth of human iPSC-derived NPCs on nanowire arrays across a wide range of array characteristics. The proliferation, viability, and interaction with the nanowire arrays were mapped depending on the array pitch and nanowire length.

22 May 2020 in Bioengineering
Verified
Journal Article
Open access
PDF file
JHJann Harberts
Jann Harberts
MKMax Kusch
Max Kusch
JOJohn O'Sullivan
John O'Sullivan
Robert ZieroldRobert Zierold
Robert Zierold
RBRobert H. Blick
Robert H. Blick
Though patch clamping at room temperature is a widely disseminated standard procedure in the electrophysiological community, it does not represent the biological system in mammals at around 37 °C. In order to better mimic the natural environment in electrophysiological studies, we present a custom-built, temperature-controlled patch clamp platform for upright microscopes, which can easily be adapted to any upright patch clamp setup independently, whether commercially available or home built. Our setup can both cool and heat the platform having only small temperature variations of less than 0.5 °C. We demonstrate our setup with patch clamp measurements at 36 °C on Jurkat T lymphocytes and human induced pluripotent stem cell-derived neurons. Passive membrane parameters and characteristic electrophysiological properties, such as the gating properties of voltage-gated ion channels and the firing of action potentials, are compared to measurements at room temperature. We observe that many processes that are not explicitly considered as temperature dependent show changes with temperature. Thus, we believe in the need of a temperature control in patch clamp measurements if improved physiological conditions are required. Furthermore, we advise researchers to only compare electrophysiological results directly that have been measured at similar temperatures since small variations in cellular properties might be caused by temperature alterations.