Hee Young Kim

Dr. Hee Young Kim

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2022 in Anesthesia and Pain Medicine
Verified
Journal Article
Open access
PDF file
SPSeyeon Park
Seyeon Park
SSSang-Wook Shin
Sang-Wook Shin
HKHye-Jin Kim
Hye-Jin Kim
GBGyeong-Jo Byeon
Gyeong-Jo Byeon
JYJi-Uk Yoon
Ji-Uk Yoon
HKHee Young Kim
Hee Young Kim
Selection and insertion of an endotracheal tube (ETT) of appropriate size for airway management during general anesthesia in pediatric patients is very important. A very small ETT increases the risk of inadequate ventilation, air leakage, and aspiration, whereas a very large ETT may cause serious complications including airway damage, post-intubation croup, and, in severe cases, subglottic stenosis. Although the pediatric larynx is conical, the narrowest part, the rima glottidis, is cylindrical in the anteroposterior dimension, regardless of development, and the cricoid ring is slightly elliptical. A cuffed ETT reduces the number of endotracheal intubation attempts, and if cuff pressure can be maintained within a safe range, the risk of airway damage may not be greater than that of an ETT without cuff. The age-based formula suggested by Cole (age/4 + 4) has long been used to select the appropriate ETT size in children. Because age-based formulas in children are not always accurate, various alternative methods for estimating the ETT size have been examined and suggested. Chest radiography, ultrasound, and a three-dimensional airway model can be used to determine the appropriate ETT size; however, there are several limitations.

1 January 2020 in Journal of Dental Anesthesia and Pain Medicine
Verified
Journal Article
Open access
PDF file
EKEun-Jung Kim
Eun-Jung Kim
HKHee Young Kim
Hee Young Kim
JAJi-hye Ahn
Ji-hye Ahn
Kim EJ, et al. J Dent Anesth Pain Med. 2020 Apr;20(2):55-61. https://doi.org/10.17245/jdapm.2020.20.2.55

2 August 2021 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
SPSeyeon Park
Seyeon Park
JAJisoo Ahn
Jisoo Ahn
SYSung Uk Yoon
Sung Uk Yoon
KCKi Seok Choo
Ki Seok Choo
HKHye-Jin Kim
Hye-Jin Kim
HKHee Young Kim
Hee Young Kim
Background: To determine the correct size of endotracheal tubes (ETTs) for endotracheal intubation of pediatric patients, new methods have been investigated. Although the three-dimensional (3D) printing technology has been successful in the field of surgery, there are not many studies in the field of anesthesia. The purpose of this study was to evaluate the accuracy of a 3D airway model for prediction of the correct ETT size, and compare the results with a conventional age-based formula in pediatric patients.Methods: Thirty-five pediatric patients under six years of age who were scheduled for congenital heart surgery were enrolled. In the pre-anesthetic period, the patient’s computed tomography (CT) images were converted to Standard Triangle Language (STL) files using the 3D conversion program. A Fused Deposition Modelling (FDM) type 3D printer was used to print 3D airway models from the sub-glottis to the upper carina. ETT size was selected by inserting various sized cuffed-ETTs to a printed 3D airway model.Results: The 3D method selected the correct ETT size in 21 out of 35 pediatric patients (60%), whereas the age-based formula selected the correct ETT size in 9 patients (26%).Conclusions: Prediction of the correct size of ETTs using a printed 3D airway model demonstrated better results than the age-based formula. This suggests that the selection of ETT size using a printed 3D airway model may be feasible for helping minimize re-intubation attempts and complications in patients with congenital heart disease and/or those with an abnormal range of growth and development.

4 January 2017 in BMJ Open
Verified
Journal Article
Open access
KKKun Hyung Kim
Kun Hyung Kim
DKDae Hun Kim
Dae Hun Kim
JBJi Min Bae
Ji Min Bae
GSGyung Mo Son
Gyung Mo Son
KKKyung Hee Kim
Kyung Hee Kim
HKHee Young Kim
Hee Young Kim
Introduction: This study aims to assess the feasibility of acupuncture and a Pericardium 6 (PC6) wristband as an add-on intervention of antiemetic medication for the prevention of postoperative nausea and vomiting (PONV) in patients undergoing elective laparoscopic colorectal cancer resection. Methods and analysis: A total of 60 participants who are scheduled to undergo elective laparoscopic resection of colorectal cancer will be recruited. An enhanced recovery after surgery protocol using standardised antiemetic medication will be provided for all participants. Participants will be equally randomised into acupuncture plus PC6 wristband (Acupuncture), PC6 wristband alone (Wristband), or no acupuncture or wristband (Control) groups using computer-generated random numbers concealed in opaque, sealed, sequentially numbered envelopes. For the acupuncture combined with PC6 wristband group, the embedded auricular acupuncture technique for preoperative anxiolysis and up to three sessions of acupuncture treatments with manual and electrical stimulation within 48 hours after surgery will be provided by qualified Korean medicine doctors. The PC6 wristband will be applied in the Acupuncture and Wristband groups, beginning 1 hour before surgery and lasting 48 hours postoperatively. The primary outcome will be the number of participants who experience moderate or severe nausea, defined as nausea at least 4 out of 10 on a severity numeric rating scale or vomiting at 24 hours after surgery. Secondary outcomes, including symptom severity, participant global assessments and satisfaction, quality of life, physiological recovery, use of medication and length of hospital stay, will be assessed. Adverse events and postoperative complications will be measured for 1 month after surgery. Ethics and dissemination: All participants will provide written informed consent. The study has been approved by the institutional review board (IRB). This pilot trial will inform a full-scale randomised trial of acupuncture combined with PC6 stimulation for the prevention of PONV in patients undergoing elective laparoscopic colorectal cancer surgery. Trial registration number: NCT02509143.

1 March 2024 in Medicine
Verified
Journal Article
Open access
EPEun Ji Park
Eun Ji Park
JBJaesang Bae
Jaesang Bae
JKJisu Kim
Jisu Kim
JYJi-Uk Yoon
Ji-Uk Yoon
WDWangseok Do
Wangseok Do
ACAh-Reum Cho
Ah-Reum Cho
Environmental concerns, especially global warming, have prompted efforts to reduce greenhouse gas emissions. Healthcare systems, including anesthesia practices, contribute to these emissions. Inhalation anesthetics have a significant environmental impact, with desflurane being the most concerning because of its high global warming potential. This study aimed to educate anesthesiologists on the environmental impact of inhalation anesthetics and assess changes in awareness and practice patterns, specifically reducing desflurane use. This study included data from patients who underwent surgery under general anesthesia 1 month before and after education on the effects of inhalation anesthetics on global warming. The primary endpoint was a change in inhalational anesthetic use. Secondary endpoints included changes in carbon dioxide equivalent (CO2e) emissions, driving equivalent, and medical costs. After the education, desflurane use decreased by 50%, whereas sevoflurane use increased by 50%. This shift resulted in a reduction in the overall amount of inhalational anesthetics used. The total CO2e and driving-equivalent values decreased significantly. The cost per anesthesia case decreased, albeit to a lesser extent than expected. Education on the environmental impact of inhalation anesthetics has successfully altered anesthesiologists’ practice patterns, leading to reduced desflurane usage. This change has resulted in decreased CO2e emissions and has had a positive effect on mitigating global warming. However, further research is required to assess the long-term impact of such education and the variability in practice patterns across different institutions.

1 January 2017 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
HKHee Young Kim
Hee Young Kim
JCJi Hyun Cheon
Ji Hyun Cheon
SBSeung Hoon Baek
Seung Hoon Baek
KKKyung Hoon Kim
Kyung Hoon Kim
TKTae Kyun Kim
Tae Kyun Kim
Using a too big or a too small size of an endotracheal tube in pediatric patients would result in tracheal injury or insufficient ventilation. Determining the appropriate endotracheal tube size is important because using an inappropriate size can cause complications. This study was performed to predict the appropriate endotracheal tube size by measuring the transverse diameter of the epiphysis of the distal radius under the assumption that the growth rates of cartilages in the entire body are close to each other. Fifty-eight children aged 3 to 10 years who required general anesthesia were intubated with an uncuffed endotracheal tube. The tube size was considered to be appropriate when leaks occurred at inspiratory peak pressures between 10 to 25 mmHg. The transverse diameters of the epiphysis were measured with an ultra-sonogram at the distal radius and the proximal phalanx of the third finger and the fifth finger. Correlations and prediction probabilities of measurements were evaluated. The number needed to harm (NNH), which indicates the number of patients who need to be intubated for one patient who needs tube exchange, was investigated. The Spearman's correlation coefficient between the endotracheal tube size and the epiphysis of the distal radius was 0.814, which was the biggest coefficient. For epiphysis of the proximal phalanx of the third finger and the fifth finger, the correlation coefficient was 0.704 and 0.701, respectively. If the Cole's formula was applied for selection of the tube size, the NNH would be 7. The appropriate endotracheal tube size could be predicted by means of the epiphyseal transverse diameter of the distal radius rather than the circumference measurements of the phalanx.