Hye-Jin Kim

Hye-Jin Kim

Auto-generated profile, based on publicly available information

Hye-Jin Kim

Department of Anesthesia and Pain Medicine, Pusan National University Yangsan Hospital, Yangsan, Korea

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2022 in Anesthesia and Pain Medicine
Verified
Journal Article
Open access
PDF file
SPSeyeon Park
Seyeon Park
SSSang-Wook Shin
Sang-Wook Shin
HKHye-Jin Kim
Hye-Jin Kim
GBGyeong-Jo Byeon
Gyeong-Jo Byeon
JYJi-Uk Yoon
Ji-Uk Yoon
HKHee Young Kim
Hee Young Kim
Selection and insertion of an endotracheal tube (ETT) of appropriate size for airway management during general anesthesia in pediatric patients is very important. A very small ETT increases the risk of inadequate ventilation, air leakage, and aspiration, whereas a very large ETT may cause serious complications including airway damage, post-intubation croup, and, in severe cases, subglottic stenosis. Although the pediatric larynx is conical, the narrowest part, the rima glottidis, is cylindrical in the anteroposterior dimension, regardless of development, and the cricoid ring is slightly elliptical. A cuffed ETT reduces the number of endotracheal intubation attempts, and if cuff pressure can be maintained within a safe range, the risk of airway damage may not be greater than that of an ETT without cuff. The age-based formula suggested by Cole (age/4 + 4) has long been used to select the appropriate ETT size in children. Because age-based formulas in children are not always accurate, various alternative methods for estimating the ETT size have been examined and suggested. Chest radiography, ultrasound, and a three-dimensional airway model can be used to determine the appropriate ETT size; however, there are several limitations.

2 August 2021 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
SPSeyeon Park
Seyeon Park
JAJisoo Ahn
Jisoo Ahn
SYSung Uk Yoon
Sung Uk Yoon
KCKi Seok Choo
Ki Seok Choo
HKHye-Jin Kim
Hye-Jin Kim
HKHee Young Kim
Hee Young Kim
Background: To determine the correct size of endotracheal tubes (ETTs) for endotracheal intubation of pediatric patients, new methods have been investigated. Although the three-dimensional (3D) printing technology has been successful in the field of surgery, there are not many studies in the field of anesthesia. The purpose of this study was to evaluate the accuracy of a 3D airway model for prediction of the correct ETT size, and compare the results with a conventional age-based formula in pediatric patients.Methods: Thirty-five pediatric patients under six years of age who were scheduled for congenital heart surgery were enrolled. In the pre-anesthetic period, the patient’s computed tomography (CT) images were converted to Standard Triangle Language (STL) files using the 3D conversion program. A Fused Deposition Modelling (FDM) type 3D printer was used to print 3D airway models from the sub-glottis to the upper carina. ETT size was selected by inserting various sized cuffed-ETTs to a printed 3D airway model.Results: The 3D method selected the correct ETT size in 21 out of 35 pediatric patients (60%), whereas the age-based formula selected the correct ETT size in 9 patients (26%).Conclusions: Prediction of the correct size of ETTs using a printed 3D airway model demonstrated better results than the age-based formula. This suggests that the selection of ETT size using a printed 3D airway model may be feasible for helping minimize re-intubation attempts and complications in patients with congenital heart disease and/or those with an abnormal range of growth and development.

31 January 2025 in Anesthesia and Pain Medicine
Verified
Journal Article
Open access
PDF file
JYJung-Pil Yoon
Jung-Pil Yoon
JYJi-Uk Yoon
Ji-Uk Yoon
HKHye-Jin Kim
Hye-Jin Kim
SPSeyeon Park
Seyeon Park
YYYeong Min Yoo
Yeong Min Yoo
HKHee Young Kim
Hee Young Kim
Background: Living-donor liver transplantation (LDLT) is a viable alternative to deceased-donor liver transplantation. Enhanced recovery after surgery protocols that include early extubation offer short-term benefits; however, the effect of immediate extubation in the operating room (OR) on long-term outcomes in patients undergoing LDLT remains unknown. We hypothesized that immediate OR extubation is associated with improved long-term outcomes in patients undergoing LDLT.Methods: This retrospective cohort study included 205 patients who underwent LDLT. The patients were classified based on the extubation location as OREX (those extubated in the OR) or NOREX (those extubated in the intensive care unit [ICU]). The primary outcome was overall survival (OS), while secondary outcomes included ICU stay, hospital stay duration, and various postoperative outcomes.Results: Among the 205 patients, 98 (47.8%) underwent extubation in the OR after LDLT. Univariate analysis revealed that OR extubation did not significantly affect OS (hazard ratio [HR]: 0.50, 95% confidence interval [CI]: 0.24–1.05; P = 0.066). Furthermore, multivariate analysis revealed no statistically significant association between OR extubation and OS (HR: 0.79, 95% CI: 0.35–1.80; P = 0.580). However, OR extubation was significantly associated with a lower incidence of 30-day composite complications and shorter ICU and hospital stays. Multivariate analysis indicated that higher preoperative platelet counts, increased serum creatinine levels, and a longer surgery duration were associated with poorer OS.Conclusions: Immediate OR extubation following LDLT surgery was associated with fewer 30-day composite complications and shorter ICU and hospital stays; however, it did not significantly improve OS compared with ICU extubation.

31 January 2021 in Anesthesia and Pain Medicine
Verified
Journal Article
Open access
PDF file
ECEun-Ji Choi
Eun-Ji Choi
HRHyun-Su Ri
Hyun-Su Ri
HPHyeonsoo Park
Hyeonsoo Park
HKHye-Jin Kim
Hye-Jin Kim
JYJi-Uk Yoon
Ji-Uk Yoon
GBGyeong-Jo Byeon
Gyeong-Jo Byeon
Background: Despite significant technological advances in the implantable pulse generator (IPG), complications can still occur. We report a case that unexpected extrusion of the IPG of spinal cord stimulation (SCS) was promptly identified and successfully removed without any complications. Case: After a car accident 4 years ago, a 55-year-old man who was diagnosed with complex local pain syndrome in his right leg. The SCS was inserted with 2 leads, with the IPG being implanted in the right lower abdomen region. Four years later, he developed extrusion of the IPG from his abdominal region. This unexpected extrusion may have been related to pressure necrosis caused by continued compression of pocket site where a belt was frequently tied. The IPG and the leads were successfully removed without infection occurring. Conclusions: To prevent unexpected extrusion of IPG, it is necessary to consider in advance whether the pocket site is pressed against the belt.

1 June 2021 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
SPSeyeon Park
Seyeon Park
JAJisoo Ahn
Jisoo Ahn
HKHye-Jin Kim
Hye-Jin Kim
ECEun-Ji Choi
Eun-Ji Choi
HKHee Young Kim
Hee Young Kim
Background: Pierre Robin sequence (PRS) patients have an increased risk of difficult intubation due to anatomical airway abnormalities, and intubation simulation with a three-dimensional (3D) printed airway model before anesthesia may facilitate safe airway management. Case: We describe the case of a 6.5-year-old boy with a history of PRS (a triad of micrognathia, glossoptosis, and airway obstruction), tracheostomy, and subglottic fibrosis who required general anesthesia. Preparation for this potentially difficult intubation included estimation of endotracheal tube size using a 3D printed airway model derived from 3D computed tomography of the airway, which enabled successful endotracheal intubation via video laryngoscopy.Conclusions: If general anesthesia is necessary in patients with dysmorphic features such as PRS and there is a history of tracheal pathology, the possibility of difficult intubation should always be considered and simulation of endotracheal intubation using a 3D printed model of the airway can be helpful clinically in such situations.

5 August 2022 in Journal of Chest Surgery
Verified
Journal Article
Open access
PDF file
HKHye-Jin Kim
Hye-Jin Kim
SSSang-Wook Shin
Sang-Wook Shin
SPSeyeon Park
Seyeon Park
HKHee Young Kim
Hee Young Kim
M.M.D.
M.D.
PHPh.D.
Ph.D.
Hye-Jin Kim, M.D., Sang-Wook Shin, M.D., Ph.D., Seyeon Park, M.D., Hee Young Kim, M.D., Ph.D.. J Chest Surg 2022;55:293-300. https://doi.org/10.5090/jcs.22.046