The determination of heavy metals in drinking water is of great importance, but it is hard to realize rapid and in-situ measurement. Laser-induced breakdown spectroscopy is an effective method for both solid and liquid sample analysis with advantages of fast and micro-destructive. However, the concentrations of heavy metals in drinking water is too low to be directly detected using LIBS. In this study, we enhanced the sensitivity of LIBS by coupling with chelating resin, which is usually used for water purification. The resin provided a rapid enrichment of the heavy metal, so the limits of detection of common LIBS system was much enhanced. Using Cadmium as the representative heavy metal, PLSR model for predicting Cd were built based on the spectral intensity (Cd 214.4 nm) with concentrations from 0 to 100 µg/L, and resulted in correlation coefficient of 0.94433 and RMSE of 7.1517 µg/L. The LoD was 3.6 µg/L. Furthermore, the volume, resin mass, adsorption time, and LIBS system parameters were optimized for practical applications. We also demonstrated that the resin can be recycled without loss in sensing ability. The combination of chelating resin with LIBS provides inexpensive, rapid, and sensitive detection method of trace heavy metal contaminants in drinking water.
Laser-induced breakdown spectroscopy (LIBS) is fast, on-line, causes little sample damage, and can be applied in remote field locations. In recent years, LIBS has been widely used in many fields of scientific research for element detection. Further application of LIBS is limited by the strong matrix effect, poor repeatability, and relatively weak detection sensitivity. The detection sensitivity is an important factor and needs to be improved for LIBS detection of minor or trace elements in samples. A variety of methods have been developed to improve detection sensitivity of LIBS. In this invited review paper, we discuss improvements in the LIBS detection sensitivity achieved with physical enhancement methods, chemical enhancement methods, mathematical methods, and combinations of multiple methods. We discuss the enhancement mechanisms, sensitivity improvements, configurations, and effects of key factors for various methods. The advantages, disadvantages, and real-time capabilities of these methods are reviewed. Finally, new trends and future perspectives for LIBS as an efficient analytical tool are discussed.
Surface-enhanced Raman spectroscopy (SERS) is an emerging technique for the detection of pesticide residues on food surfaces, permitting quantitative measurement of pesticide residues without pretreating the sample. However, previous studies have mainly involved the single Raman spectrum of samples, while have given little information on pesticide residue distribution. In this paper, gold nanoparticles were used as surface enhancers to obtain the Raman spectra of omethoate and chlorpyrifos, using the Raman shifts of 413 cm−1 (omethoate) and 346 & 634 cm−1 (chlorpyrifos) as the peaks of interest. Different concentrations of pesticide solution were quantitatively analyzed and the regression curve model was established, whereby the solutions of omethoate and chlorpyrifos were used to study the distribution of pesticide residues on an apple surface by SERS microscopy imaging. Our study shows that this method can achieve rapid and quantitative detection and obtain basic information about the distribution of pesticide residues during pesticide application, which has the potential to be applied to the studies of the diffusion and absorption processes of pesticides in agricultural products.
Poor spectral stability and low detection accuracy have limited the development of laser-induced breakdown spectroscopy (LIBS) for use in liquid analysis. A simple and fast new liquid pretreatment method, named geometric constraint liquid-to-solid conversion (GCLSC), was used in sample pretreatment for LIBS to simultaneously improve the spectral stability and detection accuracy. An aluminum (Al) target was used as a substrate. Boron (B) and chromium (Cr) in aqueous solution were determined using LIBS with GCLSC. The results showed that the spectral stability and detection accuracy of LIBS in liquid analysis could be improved by using GCLSC when compared with using filter paper assisted liquid-to-solid conversion (FPLSC) and unconstrained direct liquid-to-solid conversion (UDLSC). The relative standard deviation (RSD) values of B and Cr from the GCLSC method were 6.8% and 4.6%, respectively. The root-mean-square error of cross validation (RMSECV) values of B and Cr for GCLSC were 2.09 mg L−1 and 1.63 mg L−1, respectively. The experimental results demonstrated that the GCLSC method is promising for improving the stability and accuracy of LIBS quantitative analysis in liquid detection.