This paper carries out the assessment of load-carrying capacity of prestressed concrete sleepers, in accordance with Brazilian Standard (ABNT NBR 11709) and AREMA Standard. In a lot of railways around the world, many prestressed concrete sleepers have failed due to Rail Seat Abrasion (RSA) and corrosion. RSA is the wear degradation underneath the rail on the surface of prestressed concrete sleepers. In this paper, a numerical study was carried out to evaluate the load-carrying capacity of the prestressed concrete sleepers, using ABAQUS software. The nonlinear using Concrete Damage Plasticity model was validated by 18 experimental results, in accordance to standards. Using the validated model, the influence of different wear depth RSA, combined with corrosion of the prestressed wires, is investigated.
This paper reports the results of three thin wythe precast sandwich panels tested under axial load. Panel reinforcements and shear connectors in the current state of precast sandwich panels in the civil construction context are evaluated. The authors measured displacement at two distinct panel heights as well as along the panel width to provide load–displacement behavior at the cross-section level and broaden the experimental data on the subject. The test results developed in this research showed good agreement with the results available in the literature. In addition, as concrete-wall panel strength equations have been linked to the compressive behavior of precast sandwich panels, a brief review of empirical formulae is also offered in this paper. Moreover, empirical data since 2005, on both concentrical and eccentrical load testing available in the literature, are also reported.
Space trusses are structural systems, generally made of tubes, used worldwide because of their advantages in covering long-span roofs. In addition to having a low cost, the truss weight is relatively reduced. The load capacity of these structures depends also on the strength of their node connection. Connections made with the superposition of flattened tube ends trespassed by one bolt are, generally, known as typical nodes. They are inexpensive but present eccentricities that reduce significantly the strength of such space trusses. To increase the truss load capacity, this research presents the results of an experimental program to reduce the eccentricities of the typical nodes. This reduction is done with a new type of spacer made of encapsulated concrete with steel fiber or sisal fiber. The experimental tests showed that the trusses with typical nodes collapsed under reduced load by local failure due to high distortions at the nodes. The trusses with encapsulated concrete spacer showed good results, with an increase in collapse load of 36% and failure by buckling bars.
11 March 2019 in Fracture and Structural Integrity
In recent years, one can observe a constant worry of the scientific community on the search for demage detection techniques in structures. Such worry contributed to the progressive development of Structural Health Monitoring. This paper purpose a methodology using Continuous Wavelet Transform associated with interpolation and regularization techniques applied in the experimental and numerical mode shapes of the Dogna Bridge using only the demaged responses. The results of the analyses are presented and discussed in this paper.
This paper shows an extensive study on the Typical Connections used in Double-Layer Space Truss. For this structural system, the ends of the bars are flattened to connect the bars. However, the flattening process results in a highly plastic stamping zone susceptible to warping with the appearance of two eccentricities, one of which causes rotation of the connection, with the presence of a bending moment with local rupture resulting in progressive collapse of the entire coverage system, as already evidenced in several countries. Therefore, eccentricity in this paper is studied and an analytical solution to the problem is presented through the use of a new device called a spacer. Furthermore, a preliminary study with complex numerical simulation was carried out with nonlinear analysis in ABAQUS were evaluated. For this study, nine space trusses were experimentally tested with reinforcement spacer in reduced trusses. After confirming the efficiency of the spacer proposal, another six space trusses were tested in the laboratory, this time, on a full-scale. In this study, two types of spacers were evaluated, one made of USI SAC 350 steel and another cheaper one made from recycled tires from heavy vehicles with multiple filaments of steel and nylon wires in the rubber layers. The two devices presented very close resistance capacity values, with a resistance gain of approximately 30% in relation to connections without reinforcement, with structural failure characterized by buckling of the bars. Finally, a numerical study of space trusses with spacers was developed. In practical design terms, from these FE simulations it was possible to determine the normal stresses for different spacers applied in the different modeled spans.
4 May 2019 in International Journal for Computational Methods in Engineering Science and Mechanics
The detection of damages inside structures is of great importance because damages may be critical for serviceability and safety of structural elements. Only two reliable techniques for nondestructive examination of structures, ultrasonic and x-ray may be applied in practice for the precise location of subsurface damages. However, such techniques are expensive, time consuming, and require special procedures for their application. Current researches point toward the possible use of numerical-computational methods in assisting the detection of damages inside structures. In general, numerical methods for detecting damages, like cracks are based on Finite Element modeling and comparisons between the structures´ signatures or responses before and after damage has occurred. In this paper, the Boundary Element Method is associated with Wavelet Transform to detect damages in structures. With this association, numerical modeling of structures is more precise, simpler, and does not require the structure signature before the occurrence of the crack. After presenting the proposed numerical technique, the paper shows applications concerning the detection of subsurface cracks in structures subjected to static loads. Single and multi-cracks with different orientations inside two-dimensional structures with different support conditions are investigated. The results show the proposed numerical procedure is effective in indicating the location of damages.