In Central and Eastern Europe, a growing popularity of gas heaters as the main source of heat and domestic hot water can be observed. This is the result of new laws and strategies for funding that have been put in place to encourage households to stop using coal and replace it with cleaner energy sources. However, there is a growing concern that gas furnaces are prone to malfunction and can be a threat to occupants through CO (carbon monoxide) generation. To see how a faulty gas furnace with a clogged exhaust may affect a household, a series of multizone and computational fluid dynamics (CFD) simulations were carried out using the CONTAM software and CFD0 editor created by the National Institute of Standards and Technology (NIST). The simulations presented different placements of the furnace and ventilation outlet in an attached garage. The results showed how the placement influenced contaminant migration and occupant exposure to CO. It changed the amount of CO that infiltrated to the attached house and influenced occupant exposure. The results may be used by future users to minimize the risk of CO poisoning by using the proper natural ventilation methods together with optimal placement of the header in the household.

Nina Szczepanik-ScisloNina Szczepanik-Scislo
Nina Szczepanik-Scislo
The airtightness of buildings is continuing to grow and impact the indoor environment. Its aim is to conserve energy, but this may influence the indoor air quality and increase contaminant accumulation by limiting the amount of fresh air that infiltrates the building. The goal of this study was to quantify how the contaminants from a faulty gas furnace in a household could impact the occupants. The gas furnace was located in an attached garage and leaked carbon monoxide (CO). Multizone and CFD simulations were caried out to determine if an air terminal device (ATD) with a changing geometry could improve the air quality. The goal of the ATD was to maintain a steady air throw in the garage, while the air flow in the ventilation system would change. A steady air throw should help to remove the carbon monoxide generated from the furnace and prevent infiltration into the household. The results show that with the use of the new ATD, it was possible to maintain a steady air throw and the infiltration of CO was lowered.

21 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
Nina Szczepanik-ScisloNina Szczepanik-Scislo
Nina Szczepanik-Scislo
JSJacek Schnotale
Jacek Schnotale
This study aimed to develop a new concept for an air terminal device for a VAV (variable air volume) ventilation system that would improve overall ventilation efficiency under a varying air supply volume. In VAV systems, air volume is modified according to the thermal load in each ventilated zone. However, lowering the airflow may cause a lack of proper air distribution and lead to the degradation of hygienic conditions. To combat this phenomenon, an air terminal device with an adapting geometry to stabilize the air throw, such that it remains constant despite the changing air volume supplied through the ventilation system, was designed and studied. Simulations that were performed using the RNG k–ε model in the ANSYS Fluent application were later validated on a laboratory stand. The results of the study show that, when using the newly proposed terminal device with an adaptive geometry, it is possible to stabilize the air throw. The thermal comfort parameters such as the PMV (predicted mean vote) and PPD (predicted percentage of dissatisfied) proved that thermal comfort was maintained in a person-occupied area regardless of changing airflow though the ventilation system.

27 March 2019 in SN Applied Sciences
Verified
Journal Article
Open access
PDF file
Nina Szczepanik-ScisloNina Szczepanik-Scislo
Nina Szczepanik-Scislo
AAArkadiusz Antonowicz
Arkadiusz Antonowicz
Lukasz ScisloLukasz Scislo
Lukasz Scislo
Air quality is an important factor for human well-being, and it is crucial that when using mechanical ventilation system, air is properly distributed so it reaches every user of a ventilated zone. To improve ventilation systems, and in consequence the air quality, this paper focuses on studying the impact of an air terminal device (ATD) with a dynamically changing geometry on the effectiveness of a variable air volume (VAV) ventilation system. VAV system characterizes a change in the airflow magnitude through the system when the heat gains lower, which may be a risk for human health as air may not reach the furthest parts of a zone. To combat this threat, an ATD with a dynamically changing geometry was installed. As a ventilation quality indicator, the air throw was taken under consideration. Thanks to the new ATD, the steady air throw should be maintained despite the changes in flow in the ventilation system. To achieve this, the research was divided into two stages. The first stage included a series of computational fluid dynamics simulations that considered the alteration of the airflow and the air terminal device diameter. Afterwards, verifying laboratory measurements were conducted on a laboratory stand using a particle image velocimetry (PIV) system that included an air terminal device with a changing geometry. The results of the simulations and the PIV measurements showed that the changes in the geometry of the air terminal device improve the ventilation effectiveness of a VAV system, allowing the system to maintain a constant air throw despite the changing airflow magnitude through the system.

3 July 2018 in E3S Web of Conferences
Verified
Conference Paper
Open access
Nina Szczepanik-ScisloNina Szczepanik-Scislo
Nina Szczepanik-Scislo
AFAgnieszka Flaga-Maryańczyk
Agnieszka Flaga-Maryańczyk
The aim of the research were measurements and an attempt to model the indoor air quality (IAQ) within a studio apartment with a mechanical exhaust system, manually controlled by the occupants. The authors based the modelling on the occupancy schedule of the family members and the recorded operation duration of the ventilation system. The purpose of the performed analysis was to answer the question if it is possible and to what extent to reflect numerically the conditions within the tested object. The authors studied also the carbon dioxide level in the context of controlling the system by the residents. The simulations were carried out using the CONTAM software, developed by NIST (National Institute of Standards and Technology).

22 August 2023 in Buildings
Verified
Journal Article
Open access
PDF file
Nina Szczepanik-ScisloNina Szczepanik-Scislo
Nina Szczepanik-Scislo
Lukasz ScisloLukasz Scislo
Lukasz Scislo
Due to rising energy costs, there is a trend to return to conventional heating systems powered by solid fuel. A rise in the combination of new and old energy sources is creating unintended dual-fuel heating systems. These systems combine an old solid-fuel furnace and a new gas furnace. Usually, the old furnace was meant to be replaced by the new one and their cooperation was never intended when installing the new heating system. The occupants decided to leave the old system in fear of a rise in prices of gas or electricity or temporary problems with their supply. The study focuses on such a system and its influence on indoor air quality and thermal comfort. A series of dynamic measurements with an IoT remote sensor array in a chosen household was conducted to evaluate the behaviour of the system as well as effects on the indoor environment. Sensors measured the CO2 concentration and thermal profile in a household when using a dual-fuel heating system consisting of an old wood furnace from the 1980s and a recently installed new gas furnace. The results showed that none of the heat sources posed a threat to the occupants. Contaminants were safely removed by the exhaust systems of the furnaces. The thermal comfort, however, was influenced more by the wood furnace where fluctuations in the temperature were noticed, especially during the night. The gas furnace maintained a stable temperature that was more suitable for the occupants.