Sergio Lerma Lara

Prof. Dr. Sergio Lerma Lara

Centro Superior de Estudios Universitarios La Salle. (CSEU La Salle), Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2017 in European Journal of Neurology
Verified
Journal Article
Closed access
PDF file
JNJ. C. van Den Noort
J. C. van Den Noort
LBL. Bar‐On
L. Bar‐On
EAE. Aertbeliën
E. Aertbeliën
MBM. Bonikowski
M. Bonikowski
SBS. M. Braendvik
S. M. Braendvik
JHJaap Harlaar
Jaap Harlaar

17 July 2019 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
GDGuillaume Durandau
Guillaume Durandau
DFDario Farina
Dario Farina
GPGuillermo Asín Prieto
Guillermo Asín Prieto
IDIris Dimbwadyo-Terrer
Iris Dimbwadyo-Terrer
Sergio Lerma LaraSergio Lerma Lara
Sergio Lerma Lara
Massimo SartoriMassimo Sartori
Massimo Sartori
Research efforts in neurorehabilitation technologies have been directed towards creating robotic exoskeletons to restore motor function in impaired individuals. However, despite advances in mechatronics and bioelectrical signal processing, current robotic exoskeletons have had only modest clinical impact. A major limitation is the inability to enable exoskeleton voluntary control in neurologically impaired individuals. This hinders the possibility of optimally inducing the activity-driven neuroplastic changes that are required for recovery. We have developed a patient-specific computational model of the human musculoskeletal system controlled via neural surrogates, i.e., electromyography-derived neural activations to muscles. The electromyography-driven musculoskeletal model was synthesized into a human-machine interface (HMI) that enabled poststroke and incomplete spinal cord injury patients to voluntarily control multiple joints in a multifunctional robotic exoskeleton in real time. We demonstrated patients’ control accuracy across a wide range of lower-extremity motor tasks. Remarkably, an increased level of exoskeleton assistance always resulted in a reduction in both amplitude and variability in muscle activations as well as in the mechanical moments required to perform a motor task. Since small discrepancies in onset time between human limb movement and that of the parallel exoskeleton would potentially increase human neuromuscular effort, these results demonstrate that the developed HMI precisely synchronizes the device actuation with residual voluntary muscle contraction capacity in neurologically impaired patients. Continuous voluntary control of robotic exoskeletons (i.e. event-free and task-independent) has never been demonstrated before in populations with paretic and spastic-like muscle activity, such as those investigated in this study. Our proposed methodology may open new avenues for harnessing residual neuromuscular function in neurologically impaired individuals via symbiotic wearable robots.

27 July 2018 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
CBCristina Bayón
Cristina Bayón
TMTeresa Martín-Lorenzo
Teresa Martín-Lorenzo
BMBeatriz Moral-Saiz
Beatriz Moral-Saiz
ÓRÓscar Ramírez
Óscar Ramírez
ÁPÁlvaro Pérez-Somarriba
Álvaro Pérez-Somarriba
EREduardo Rocon
Eduardo Rocon
The use of robotic trainers has increased with the aim of improving gait function in patients with limitations. Nevertheless, there is an absence of studies that deeply describe detailed guidelines of how to correctly implement robot-based treatments for gait rehabilitation. This contribution proposes an accurate robot-based training program for gait rehabilitation of pediatric population with Cerebral Palsy (CP). The program is focused on the achievement of some specifications defined by the International Classification of Functioning, Disability and Health framework, Children and Youth version (ICF-CY). It is framed on 16 non-consecutive sessions where motor control, strength and power exercises of lower limbs are performed in parallel with a postural control strategy. A clinical evaluation with four pediatric patients with CP using the CPWalker robotic platform is presented. The preliminary evaluation with patients with CP shows improvements in several aspects as strength (74.03 ± 40.20%), mean velocity (21.46 ± 33.79%), step length (17.95 ± 20.45%) or gait performance (e.g. 66 ± 63.54% in Gross Motor Function Measure-88 items, E and D dimensions). The improvements achieved in the short term show the importance of working strength and power functions meanwhile over-ground training with postural control. This research could serve as preliminary support for future clinical implementations in any robotic device. The study was carried out with the number R-0032/12 from Local Ethical Committee of the Hospital Infantil Niño Jesús. Public trial registered on March 23, 2017: ISRCTN18254257 .

1 May 2017 in Robotics and Autonomous Systems
Verified
Journal Article
Open access
CBCristina Bayón
Cristina Bayón
ORO. Ramírez
O. Ramírez
José Ignacio SerranoJosé Ignacio Serrano
José Ignacio Serrano
María Dolores MesaMaría Dolores Mesa
María Dolores Mesa
APA. Pérez-Somarriba
A. Pérez-Somarriba
EREduardo Rocon
Eduardo Rocon
The term Cerebral Palsy (CP) is a set of neurological disorders that appear in infancy or early childhood and permanently affect body movement and muscle coordination. The prevalence of CP is twothree per 1000 births. Emerging rehabilitation therapies through new strategies are needed to diminish the assistance required for these patients, promoting their functional capability. This paper presents a new robotic platform called CPWalker for gait rehabilitation in patients with CP, which allows them to start experiencing autonomous locomotion through novel robot-based therapies. The platform (smart walker +exoskeleton) is controlled by a multimodal interface that gives high versatility. The therapeutic approach, as well as the details of the interactions may be defined through this interface. CPWalker concept aims to promote the earlier incorporation of patients with CP to the rehabilitation treatment and increases the level of intensity and frequency of the exercises. This will enable the maintenance of therapeutic methods on a daily basis, with the intention of leading to significant improvements in the treatment outcomes. Rehabilitation with free displacement and not restricted to a treadmill.Integration of central nervous system into therapies.Postural control and partial body weight support for individuals with more severe disorders.Assist as needed approach.Locomotion strategy based on laser sensor.

1 June 2014 in Manual Therapy
Verified
Journal Article
Closed access
HPHonorio Izquierdo Pérez
Honorio Izquierdo Pérez
JPJose Luis Alonso Perez
Jose Luis Alonso Perez
AGAlfonso Gil-Martínez
Alfonso Gil-Martínez
Roy LA TOUCHERoy LA TOUCHE
Roy LA TOUCHE
Sergio Lerma LaraSergio Lerma Lara
Sergio Lerma Lara
Josué Fernandez CarneroJosué Fernandez Carnero
Josué Fernandez Carnero

28 January 2019 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
LALuis Felipe Aycardi
Luis Felipe Aycardi
Carlos A. CifuentesCarlos A. Cifuentes
Carlos A. Cifuentes
MMMarcela Múnera
Marcela Múnera
CBCristina Bayón
Cristina Bayón
OROscar Ramírez
Oscar Ramírez
EREduardo Rocon
Eduardo Rocon
Cerebral Palsy (CP) is the most common cause of permanent serious physical disability in childhood. Although many platforms have been developed, so far there are still not precise guidelines for the rehabilitation of the population with CP. The CPWalker is a robotic platform for the rehabilitation of children with CP, through which they can start experiencing autonomous locomotion in the rehabilitation environment. It allows the possibility of free movement and includes physical and cognitive interfaces into the therapy. The main objective of this work is to evaluate the effects of the CPWalker-based rehabilitation intervention in children with CP by comparing different gait parameters before, during and after the use of the platform. The evaluation was divided in three stages where the gait parameters and symmetry indexes of eight subjects with CP were evaluated. In the first stage patients walked only with the help they receive normally in daily life. During the second stage they walked with the CPWalker and finally, in the third stage, they repeated their gait without the platform. In all stages they wore an inertial G-Sensor Ⓡ while walking through the hospital facilities. The results showed statistical significant differences in several spatio-temporal parameters, pelvic angles and general gait cycle parameters, with and without the use of the robotic device. For the eight patients: cadence, speed and stride length presented similar values when comparing before and after the therapy. However, they decreased during the intervention (both means and standard deviations). No significant differences were found in the symmetry indexes with the use of the platform. In spite of this, a reduction in the pelvic angles ranges and propulsion was observed. The effect of using the device was analyzed for spatio-temporal parameters, pelvic girdle angles and general gait cycle parameters. Among the eighteen initial parameters, seven presented a statistical significant difference when comparing stage 2 of the intervention with stages 1 and 3. Those changes showed the potential of the CPWalker to improve muscular strength and gait patterns of the patients with CP in the long term and to provide useful information for the design of the future generations of rehabilitation robotic devices.