Massimo Sartori

Prof. Massimo Sartori

University of Twente
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015 in Journal of Biomechanics
Verified
Journal Article
Open access
CPClaudio Pizzolato
Claudio Pizzolato
DLDavid Lloyd
David Lloyd
Massimo SartoriMassimo Sartori
Massimo Sartori
ECElena Ceseracciu
Elena Ceseracciu
TBThor F. Besier
Thor F. Besier
MRMonica Reggiani
Monica Reggiani
Personalized neuromusculoskeletal (NMS) models can represent the neurological, physiological, and anatomical characteristics of an individual and can be used to estimate the forces generated inside the human body. Currently, publicly available software to calculate muscle forces are restricted to static and dynamic optimisation methods, or limited to isometric tasks only. We have created and made freely available for the research community the Calibrated EMG-Informed NMS Modelling Toolbox (CEINMS), an OpenSim plug-in that enables investigators to predict different neural control solutions for the same musculoskeletal geometry and measured movements. CEINMS comprises EMG-driven and EMG-informed algorithms that have been previously published and tested. It operates on dynamic skeletal models possessing any number of degrees of freedom and musculotendon units and can be calibrated to the individual to predict measured joint moments and EMG patterns. In this paper we describe the components of CEINMS and its integration with OpenSim. We then analyse how EMG-driven, EMG-assisted, and static optimisation neural control solutions affect the estimated joint moments, muscle forces, and muscle excitations, including muscle co-contraction.

6 February 2017 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
DFDario Farina
Dario Farina
IVIvan Vujaklija
Ivan Vujaklija
Massimo SartoriMassimo Sartori
Massimo Sartori
TKTamás Kapelner
Tamás Kapelner
FNFrancesco Negro
Francesco Negro
OAOskar C. Aszmann
Oskar C. Aszmann

26 December 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Massimo SartoriMassimo Sartori
Massimo Sartori
MRMonica Reggiani
Monica Reggiani
DFDario Farina
Dario Farina
DLDavid Lloyd
David Lloyd
This work examined if currently available electromyography (EMG) driven models, that are calibrated to satisfy joint moments about one single degree of freedom (DOF), could provide the same musculotendon unit (MTU) force solution, when driven by the same input data, but calibrated about a different DOF. We then developed a novel and comprehensive EMG-driven model of the human lower extremity that used EMG signals from 16 muscle groups to drive 34 MTUs and satisfy the resulting joint moments simultaneously produced about four DOFs during different motor tasks. This also led to the development of a calibration procedure that allowed identifying a set of subject-specific parameters that ensured physiological behavior for the 34 MTUs. Results showed that currently available single-DOF models did not provide the same unique MTU force solution for the same input data. On the other hand, the MTU force solution predicted by our proposed multi-DOF model satisfied joint moments about multiple DOFs without loss of accuracy compared to single-DOF models corresponding to each of the four DOFs. The predicted MTU force solution was (1) a function of experimentally measured EMGs, (2) the result of physiological MTU excitation, (3) reflected different MTU contraction strategies associated to different motor tasks, (4) coordinated a greater number of MTUs with respect to currently available single-DOF models, and (5) was not specific to an individual DOF dynamics. Therefore, our proposed methodology has the potential of producing a more dynamically consistent and generalizable MTU force solution than was possible using single-DOF EMG-driven models. This will help better address the important scientific questions previously approached using single-DOF EMG-driven modeling. Furthermore, it might have applications in the development of human-machine interfaces for assistive devices.

1 November 2013 in Journal of Biomechanics
Verified
Journal Article
Open access
GPGerus Pauline
Gerus Pauline
Massimo SartoriMassimo Sartori
Massimo Sartori
TBThor F. Besier
Thor F. Besier
Benjamin FreglyBenjamin Fregly
Benjamin Fregly
SDScott L. Delp
Scott L. Delp
DLDavid Lloyd
David Lloyd
Estimating tibiofemoral joint contact forces is important for understanding the initiation and progression of knee osteoarthritis. However, tibiofemoral contact force predictions are influenced by many factors including muscle forces and anatomical representations of the knee joint. This study aimed to investigate the influence of subject-specific geometry and knee joint kinematics on the prediction of tibiofemoral contact forces using a calibrated EMG-driven neuromusculoskeletal model of the knee. One participant fitted with an instrumented total knee replacement walked at a self-selected speed while medial and lateral tibiofemoral contact forces, ground reaction forces, whole-body kinematics, and lower-limb muscle activity were simultaneously measured. The combination of generic and subject-specific knee joint geometry and kinematics resulted in four different OpenSim models used to estimate muscle-tendon lengths and moment arms. The subject-specific geometric model was created from CT scans and the subject-specific knee joint kinematics representing the translation of the tibia relative to the femur was obtained from fluoroscopy. The EMG-driven model was calibrated using one walking trial, but with three different cost functions that tracked the knee flexion/extension moments with and without constraint over the estimated joint contact forces. The calibrated models then predicted the medial and lateral tibiofemoral contact forces for five other different walking trials. The use of subject-specific models with minimization of the peak tibiofemoral contact forces improved the accuracy of medial contact forces by 47% and lateral contact forces by 7%, respectively compared with the use of generic musculoskeletal model.


1 May 2016 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
Massimo SartoriMassimo Sartori
Massimo Sartori
DLDavid Lloyd
David Lloyd
DFDario Farina
Dario Farina
Objectives: The development of neurorehabilitation technologies requires the profound understanding of the mechanisms underlying an individual's motor ability and impairment. A major factor limiting this understanding is the difficulty of bridging between events taking place at the neurophysiologic level (i.e., motor neuron firings) with those emerging at the musculoskeletal level (i.e. joint actuation), in vivo in the intact moving human. This review presents emerging model-based methodologies for filling this gap that are promising for developing clinically viable technologies. Methods: We provide a design overview of musculoskeletal modeling formulations driven by recordings of neuromuscular activity with a critical comparison to alternative model-free approaches in the context of neurorehabilitation technologies. We present advanced electromyography-based techniques for interfacing with the human nervous system and model-based techniques for translating the extracted neural information into estimates of motor function. Results: We introduce representative application areas where modeling is relevant for accessing neuromuscular variables that could not be measured experimentally. We then show how these variables are used for designing personalized rehabilitation interventions, biologically inspired limbs, and human-machine interfaces. Conclusion: The ability of using electrophysiological recordings to inform biomechanical models enables accessing a broader range of neuromechanical variables than analyzing electrophysiological data or movement data individually. This enables understanding the neuromechanical interplay underlying in vivo movement function, pathology, and robot-assisted motor recovery. Significance: Filling the gap between our understandings of movement neural and mechanical functions is central for addressing one of the major challenges in neurorehabilitation: personalizing current technologies and interventions to an individual's anatomy and impairment.