The analysis of exhaled breath is drawing a high degree of interest in the diagnostics of various diseases, including lung cancer. Electronic nose (E-nose) technology is one of the perspective approaches in the field due to its relative simplicity and cost efficiency. The use of an E-nose together with pattern recognition algorithms allow ‘breath-prints’ to be discriminated. The aim of this study was to develop an efficient online E-nose-based lung cancer diagnostic method via exhaled breath analysis with the use of some statistical classification methods. A developed multisensory system consisting of six metal oxide chemoresistance gas sensors was employed in three temperature regimes. This study involved 118 individuals: 65 in the lung cancer group (cytologically verified) and 53 in the healthy control group. The exhaled breath samples of the volunteers were analysed using the developed E-nose system. The dataset obtained, consisting of the sensor responses, was pre-processed and split into training (70%) and test (30%) subsets. The training data was used to fit the classification models; the test data was used for the estimation of prediction possibility. Logistic regression was found to be an adequate data-processing approach. The performance of the developed method was promising for the screening purposes (sensitivity—95.0%, specificity—100.0%, accuracy—97.2%). This shows the applicability of the gas-sensitive sensor array for the exhaled breath diagnostics. Metal oxide sensors are highly sensitive, low-cost and stable, and their poor sensitivity can be enhanced by integrating them with machine learning algorithms, as can be seen in this study. All experiments were carried out with the permission of the N.N. Petrov Research Institute of Oncology ethics committee no. 15/83 dated March 15, 2017.
Early detection of lung cancer usually markedly increases the efficiency of therapy. However, the currently employed diagnostic approaches are not sufficiently effective, resulting in late detection of the disease and high patient mortality. Therefore, development of a high-throughput and reliable diagnostic method is a priority task requiring fast solution. Analysis of exhaled air for a number of organic compounds recognized as lung cancer biomarkers seems to be a promising approach for early diagnosis of the disease. This issue attracts growing interest, as indicated by increasing number of publications on this topic. This review surveys contemporary analytical techniques for analysis of exhaled air, including various spectroscopic and mass spectral methods and also gas sensor-based methods. The key benefits and shortcomings of the techniques, sample injection and pre-concentration methods, and the potential applicability of the methods for lung cancer detection are discussed. The prospects of simultaneous application of several analytical techniques and approaches for the early diagnosis are demonstrated.The bibliography includes 147 references.
A direct method of uranium and thorium determination in non-conducting geological samples using time-of-flight mass spectrometry with pulsed glow discharge was proposed. The following rock specimens were analysed: metamict zircon, metamict rinkite, metamict samarskite (Y–Fe-niobate), pyrochlore and jacinth. For sample sputtering a combined hollow cathode cell of high purity aluminium or tantalum hollow cathodes was used. Powdered or monolith samples were pressed into the surface of the powdered metal prior to analysis. Model samples (artificial mixtures of oxides) were proposed for calibration; additionally, relative sensitivity factors, internal standardisation and standard additions were employed. For validation, IAEA artificially prepared uranium ore reference material was analysed. For additional validation, the obtained results for real mineral samples were compared to the results of inductively coupled plasma optical emission spectrometry after sample dissolution and semi-quantitative data of energy dispersive X-ray spectrometry. Limits of detection (3σ) for the designed method were 0.3 ppm for uranium and 0.5 ppm for thorium, which is comparable to laser ablation inductively coupled plasma mass spectrometry. The method was also tested for capability to measure isotope ratios for lead and uranium without specific isotope calibration. Acquired isotopic ratios of uranium and lead corresponded to their natural abundances within the experimental error.
5 December 2016 in Journal of Analytical Atomic Spectrometry