Marta Czajkowska

Ms. Marta Czajkowska

Department of Laryngology , Medical University of Silesia, Katowice 40-027, Poland;
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Łukasz ZadrożnyŁukasz Zadrożny
Łukasz Zadrożny
PRPiotr Regulski
Piotr Regulski
KBKatarzyna Brus-Sawczuk
Katarzyna Brus-Sawczuk
MCMarta Czajkowska
Marta Czajkowska
LPLaszlo Parkanyi
Laszlo Parkanyi
Eitan MijiritskyEitan Mijiritsky
Eitan Mijiritsky
The aim of this study was to assess the reliability of the artificial intelligence (AI) automatic evaluation of panoramic radiographs (PRs). Thirty PRs, covering at least six teeth with the possibility of assessing the marginal and apical periodontium, were uploaded to the Diagnocat (LLC Diagnocat, Moscow, Russia) account, and the radiologic report of each was generated as the basis of automatic evaluation. The same PRs were manually evaluated by three independent evaluators with 12, 15, and 28 years of experience in dentistry, respectively. The data were collected in such a way as to allow statistical analysis with SPSS Statistics software (IBM, Armonk, NY, USA). A total of 90 reports were created for 30 PRs. The AI protocol showed very high specificity (above 0.9) in all assessments compared to ground truth except from periodontal bone loss. Statistical analysis showed a high interclass correlation coefficient (ICC > 0.75) for all interevaluator assessments, proving the good credibility of the ground truth and the reproducibility of the reports. Unacceptable reliability was obtained for caries assessment (ICC = 0.681) and periapical lesions assessment (ICC = 0.619). The tested AI system can be helpful as an initial evaluation of screening PRs, giving appropriate credibility reports and suggesting additional diagnostic methods for more accurate evaluation if needed.

13 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
MCMarta Czajkowska
Marta Czajkowska
EWEwa Walejewska
Ewa Walejewska
Łukasz ZadrożnyŁukasz Zadrożny
Łukasz Zadrożny
MWMonika Wieczorek-Czarnocka
Monika Wieczorek-Czarnocka
WŚWojciech Święszkowski
Wojciech Święszkowski
JMJarosław Markowski
Jarosław Markowski
This study was conducted to test possibilities of application of 3D printed dental models (DMs) in terms of their accuracy and physical properties. In this work, stone models of mandibles were cast from alginate impressions of 10 patients and scanned in order to obtain 3D printed acrylic replicas. The diagnostic value was tested as matching of model scans on three levels: peak of cusps, occlusal surface, and all teeth surfaces. The mechanical properties of acrylic and stone samples, specifically the impact strength, shore D hardness, and flexural and compressive strength were investigated according to ISO standards. The matching of models’ surfaces was the highest on the level of peaks of cusps (average lack of deviations, 0.21 mm) and the lowest on the level of all teeth surfaces (average lack of deviations, 0.64 mm). Acrylic samples subjected to mechanical testing, as expected, showed higher mechanical properties as compared to the specimens made of dental stone. In the present study we demonstrated that 3D printed acrylic models could be ideal representatives in the case of use as a diagnostic tool and as a part of medical records. The acrylic samples exhibited not only higher mechanical properties, but also showed better accuracy comparing to dental stone.

1 December 2021 in Journal of Dentistry
Verified
Journal Article
Open access
Marco TallaricoMarco Tallarico
Marco Tallarico
MCMarta Czajkowska
Marta Czajkowska
Marco CicciùMarco Cicciù
Marco Cicciù
FGFrancesco Giardina
Francesco Giardina
AMArmando Minciarelli
Armando Minciarelli
SMSilvio Mario Meloni
Silvio Mario Meloni
The aim of the present systematic review was to evaluate whether there were any differences in the three-dimensional accuracy and the implant survival rate of implants placed using computer-assisted planning and surgical templates with or without metallic sleeves. This systematic review was written according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and registered to the PROSPERO (International prospective register of systematic reviews) database. PICOS (population, intervention, control, outcomes, and studies) question was assessed, too. Search strategy encompassed the online (MedLine) literature from 1990 up to December 2020 published in English, and evaluating the accuracy of surgical templates with and without metallic sleeves in partial or complete patients. Only in vivo, randomized controlled trial and observational studies were included. Quality assessment of selected full text articles was performed according to the CONSORT (CONsolidated Standards of Reporting Trials) and STROBE (Strengthening the Reporting of Observational studies in Epidemiology) statement guidelines, respectively. For data analysis, the three-dimensional accuracy and the overall implant survival rate was calculated and compared between implants placed using surgical templates with or without metallic sleeves. A total of 12 articles fulfilled the inclusion/exclusion criteria. Data from 264 patients with 614 implants were subjected to quality assessment (templates with metallic sleeves: 279 implants and 136 patients; templates without metallic sleeves: 335 implants and 128 patients). In all the three deviation parameters (angular, vertical, and horizontal), the differences in average accuracy were noticed (angular 2.33° ± 2.01° versus 3.09° ± 1.65°, vertical: 0.62 ± 0.36 [mm] versus 0.95 ± 0.42 [mm]; and horizontal: 0.62 ± 0.41 [mm] and 1.11 ± 0.57 [mm]. No differences was found regarding overall implant survival rate (0.4891). With the limitations of the present study, the surgical templates without metallic sleeves demonstrated high level of accuracy in all the three-dimensional measurements, when used to rehabilitate partially edentulous patients. Further randomized controlled trials, reporting according to the CONSORT guidelines are needed to confirm that the differences in accuracy depended on the type of used templates.

18 July 2022 in Prosthesis
Verified
Journal Article
Open access
PDF file
Marco TallaricoMarco Tallarico
Marco Tallarico
DGDavide Galiffi
Davide Galiffi
RSRoberto Scrascia
Roberto Scrascia
MGMaurizio Gualandri
Maurizio Gualandri
Łukasz ZadrożnyŁukasz Zadrożny
Łukasz Zadrożny
MPMilena Pisano
Milena Pisano
Fully digital workflow in implant dentistry is ever increasing. Treatment of partial edentulous cases is well-documented; nevertheless, complete edentulous cases are still a challenge. To present several innovations in the treatment of complete edentulous patients using digital solutions, both for implant placement and restoration delivery, was the objective of this study. It was designed as a retrospective case series study, aimed to tune further research with larger sample size, and a longer follow-up. Patients requiring complete, implant-supported restoration were asked to participate in this study. Enrolled patients were treated with four implants, immediate loading and a definitive complete arch restoration. Patients were treated using computer-assisted, template-based surgery. Multi-piece surgical templates were used to accurately place the implants, to manage the bone if needed and to make immediate loading procedure quicker and easier. After osseointegration period, definitive, extra-oral, digital impressions were taken using newly developed scan analogs, connected in the patient mouth using temporary cylinders and stabilized by means of the low-shrinkage, flowable, resin composite. Outcomes were implant and prosthesis survival rate, complications, accuracy, and patient satisfaction. Radiographic evaluation performed with a preliminary, radiopaque aluminum try-in, was used to test the accuracy of the digital impressions. Overall, 20 implants were placed in five patients. All the implants osseointegrated without complications. One impression was taken a second time due to inaccuracy of the aluminum tray-in. Finally, all of the patients were completely satisfied with both surgical and prosthetic procedures. Within the limitations of this case series, multi-piece surgical templates showed promising results improving the clinician’s confidence in the case of bone reduction, post-extractive implants and immediate loading. The prosthetic template increased the trueness of the digital impression for complete edentulous patients. Finally, even if an impression was performed again, the scan-analog used for extra-oral chair-side digital impressions seemed to be a promising tool. Continuous improvements and further study are needed to confirm these preliminary results.

30 January 2022 in Prosthesis
Verified
Journal Article
Open access
PDF file
Łukasz ZadrożnyŁukasz Zadrożny
Łukasz Zadrożny
MCMarta Czajkowska
Marta Czajkowska
Marco TallaricoMarco Tallarico
Marco Tallarico
Leopold WagnerLeopold Wagner
Leopold Wagner
JMJarosław Markowski
Jarosław Markowski
Marco CicciùMarco Cicciù
Marco Cicciù
Numerous types of prosthodontics surgical guides, with and without metallic sleeves, have been found to be useful in clinical studies. The aim of this in vitro research was to compare the time required to complete the surgical procedure with two differently designed surgical prosthetic templates. Ten identical prototype models of mandible based on a CBCT and optical scan of a partially edentulous patient with missing teeth numbers 37, 46, and 47 were prepared and then printed. Five of these models were used for implant site preparation with a surgical guide without metal sleeves and dedicated surgical kit, and the other five models were used for the same procedure performed with a surgical guide with metal sleeves and a dedicated surgical kit. The time of implant site preparation was measured and recorded. Statistical analysis was performed using Student’s t-test for independent samples. Differences between groups were found to be statistically significant (t = −9.94; df = 28; p = 0.0000) with a lower value in favor of the surgical templates without metallic sleeves. Different types of prosthodontics surgical guides, with or without metallic sleeves, seemed to be an important factor which can significantly impact the time of implant site preparation and, therefore, the overall surgical procedure.

Łukasz ZadrożnyŁukasz Zadrożny
Łukasz Zadrożny
MCMarta Czajkowska
Marta Czajkowska
Eitan MijiritskyEitan Mijiritsky
Eitan Mijiritsky
Leopold WagnerLeopold Wagner
Leopold Wagner
Repeatability and precision are major factors which have an influence on final implant treatment results. The aim of this study was to evaluate the repeatability of freehand implant procedures assisted with special plastic sleeves which are placed on the drill to guarantee the proper mesiodistal distance from the landmark’s surface. Patient data required for implant treatment, including images of mandibles from CBCT scans and virtual models of soft tissues and teeth, were used to prepare complete virtual models of patient clinical conditions. The models were saved as STL files and 3D printed in five copies. Drilling procedures were done at positions 37, 46 and 47. Each model was scanned with pins in the osteotomies and compared using digital aligning of the models’ surfaces. The average deviation was −1.38 ± 1.4 mm. Average deviations on guide pins placed at position 37 were −0.46 ± 0.59 mm, at position 46 were −1.46 ± 0.88 mm (landmark’s surface of both: distal tooth’s surface), and at position 47 were the highest: −2.69 ± 1.62 mm (landmark’s surface: surface of plastic sleeve). The following conclusion was drawn: Using universal plastic sleeves could improve implant procedure precision especially in the case of partially edentulous patients.