Vamsy Chodavarapu

Dr. Vamsy Chodavarapu

Department of Electrical and Computer Engineering, McGill University, 3480 University Street, Montreal, QC H3A2A7, Canada

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2008 in Sensors
Verified
Journal Article
Open access
PDF file
MHMohamad HajjHassan
Mohamad HajjHassan
VCVamsy Chodavarapu
Vamsy Chodavarapu
SMSam Musallam
Sam Musallam
Neural probe technologies have already had a significant positive effect on our understanding of the brain by revealing the functioning of networks of biological neurons. Probes are implanted in different areas of the brain to record and/or stimulate specific sites in the brain. Neural probes are currently used in many clinical settings for diagnosis of brain diseases such as seizers, epilepsy, migraine, Alzheimer’s, and dementia. We find these devices assisting paralyzed patients by allowing them to operate computers or robots using their neural activity. In recent years, probe technologies were assisted by rapid advancements in microfabrication and microelectronic technologies and thus are enabling highly functional and robust neural probes which are opening new and exciting avenues in neural sciences and brain machine interfaces. With a wide variety of probes that have been designed, fabricated, and tested to date, this review aims to provide an overview of the advances and recent progress in the microfabrication techniques of neural probes. In addition, we aim to highlight the challenges faced in developing and implementing ultralong multi-site recording probes that are needed to monitor neural activity from deeper regions in the brain. Finally, we review techniques that can improve the biocompatibility of the neural probes to minimize the immune response and encourage neural growth around the electrodes for long term implantation studies.

27 August 2008 in Sensors
Verified
Journal Article
Open access
PDF file
SRSumitra Rajagopalan
Sumitra Rajagopalan
Mohamad SawanMohamad Sawan
Mohamad Sawan
EGEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
OSOumarou Savadogo
Oumarou Savadogo
VCVamsy Chodavarapu
Vamsy Chodavarapu
This paper describes a new technique to measure urine volume in patients with urinary bladder dysfunction. Polypyrrole – an electronically conducting polymer - is chemically deposited on a highly elastic fabric. This fabric, when placed around a phantom bladder, produced a reproducible change in electrical resistance on stretching. The resistance response to stretching is linear in 20%-40% strain variation. This change in resistance is influenced by chemical fabrication conditions. We also demonstrate the dynamic mechanical testing of the patterned polypyrrole on fabric in order to show the feasibility of passive interrogation of the strain sensor for biomedical sensing applications.

25 March 2015 in Sensors
Verified
Journal Article
Open access
PDF file
AMAdel Merdassi
Adel Merdassi
PYPeng Yang
Peng Yang
VCVamsy Chodavarapu
Vamsy Chodavarapu
We present the design and fabrication of a single axis low noise accelerometer in an unmodified commercial MicroElectroMechanical Systems (MEMS) process. The new microfabrication process, MEMS Integrated Design for Inertial Sensors (MIDIS), introduced by Teledyne DALSA Inc. allows wafer level vacuum encapsulation at 10 milliTorr which provides a high Quality factor and reduces noise interference on the MEMS sensor devices. The MIDIS process is based on high aspect ratio bulk micromachining of single-crystal silicon layer that is vacuum encapsulated between two other silicon handle wafers. The process includes sealed Through Silicon Vias (TSVs) for compact design and flip-chip integration with signal processing circuits. The proposed accelerometer design is sensitive to single-axis in-plane acceleration and uses a differential capacitance measurement. Over ±1 g measurement range, the measured sensitivity was 1fF/g. The accelerometer system was designed to provide a detection resolution of 33 milli-g over the operational range of ±100 g.

12 February 2015 in Sensors
Verified
Journal Article
Open access
PDF file
YWYucai Wang
Yucai Wang
VCVamsy Chodavarapu
Vamsy Chodavarapu
We describe a Complementary Metal-Oxide Semiconductor (CMOS) differential interface circuit for capacitive Micro-Electro-Mechanical Systems (MEMS) pressure sensors that is functional over a wide temperature range between −55 °C and 225 °C. The circuit is implemented using IBM 0.13 μm CMOS technology with 2.5 V power supply. A constant-gm biasing technique is used to mitigate performance degradation at high temperatures. The circuit offers the flexibility to interface with MEMS sensors with a wide range of the steady-state capacitance values from 0.5 pF to 10 pF. Simulation results show that the circuitry has excellent linearity and stability over the wide temperature range. Experimental results confirm that the temperature effects on the circuitry are small, with an overall linearity error around 2%.

29 April 2011 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
DDDaisy S. Daivasagaya
Daisy S. Daivasagaya
LYLei Yao
Lei Yao
KYKa Yi Yung
Ka Yi Yung
MHMohamad Hajj-Hassan
Mohamad Hajj-Hassan
MCMaurice C. Cheung
Maurice C. Cheung
Frank V. BrightFrank V. Bright
Frank V. Bright

1 December 2008 in Sensors
Verified
Journal Article
Open access
PDF file
MHMohamad Hajj-Hassan
Mohamad Hajj-Hassan
TGTimothy Gonzalez
Timothy Gonzalez
EGEbrahim Ghafar-Zadeh
Ebrahim Ghafar-Zadeh
HDHagop Djeghelian
Hagop Djeghelian
VCVamsy Chodavarapu
Vamsy Chodavarapu
DTDaniel Therriault
Daniel Therriault
We describe an automated robotic technique called direct-dispense to fabricate a polymeric platform that supports optical sensor arrays. Direct-dispense, which is a type of the emerging direct-write microfabrication techniques, uses fugitive organic inks in combination with cross-linkable polymers to create microfluidic channels and other microstructures. Specifically, we describe an application of direct-dispensing to develop optical biochemical sensors by fabricating planar ridge waveguides that support sol-gelderived xerogel-based thin films. The xerogel-based sensor materials act as host media to house luminophore biochemical recognition elements. As a prototype implementation, we demonstrate gaseous oxygen (O2) responsive optical sensors that operate on the basis of monitoring luminescence intensity signals. The optical sensor employs a Light Emitting Diode (LED) excitation source and a standard silicon photodiode as the detector. The sensor operates over the full scale (0%-100%) of O2 concentrations with a response time of less than 1 second. This work has implications for the development of miniaturized multisensor platforms that can be cost-effectively and reliably mass-produced.