Radon (222Rn) and thoron (220Rn), sources of natural background radiation, have been the subjects of long-standing studies, including research into radon and thoron as major causes of lung cancer at domestic and international levels. In this regard, radon and thoron measurement studies have been widely conducted all over the world. Generally, the techniques used relate to passive nuclear track detectors. Some surveys have shown that passive monitors for radon are sensitive to thoron, and hence some measured results have probably overestimated radon concentrations. This study investigated radon and thoron measurements in domestic and international surveys using the passive radon–thoron discriminative monitor, commercially named RADUET. This paper attempts to provide an understanding of discriminative measurements of radon isotopes and to present an evidence-based roadmap.
A long-term measurement technique of radon exhalation rate was previously developed using a passive type radon and thoron discriminative monitor and a ventilated type accumulation chamber. In the present study, this technique was applied to evaluate the thoron exhalation rate as well, and long-term measurements of radon and thoron exhalation rates were conducted for four years in Gifu Prefecture. The ventilated type accumulation chamber (0.8 × 0.8 × 1.0 m3) with an open bottom was embedded 15 cm into the ground. The vertical distributions of radon and thoron activity concentrations from the ground were obtained using passive type radon-thoron discriminative monitors (RADUETs). The RADUETs were placed at 1, 3, 10, 30, and 80 cm above the ground inside the accumulation chamber. The measurements were conducted from autumn 2014 to autumn 2018. These long-term results were found to be in good agreement with the values obtained by another methodology. The radon exhalation rates from the ground showed a clearly seasonal variation. Similar to findings of previous studies, radon exhalation rates from summer to autumn were relatively higher than those from winter to spring. In contrast, thoron exhalation rates were not found to show seasonal variation.
The world community has long used natural hot springs for tourist and medicinal purposes. In Indonesia, the province of West Java, which is naturally surrounded by volcanoes, is the main destination for hot spring tourism. This paper is the first report on radon measurements in tourism natural hot spring water in Indonesia as part of radiation protection for public health. The purpose of this paper is to study the contribution of radon doses from natural hot spring water and thereby facilitate radiation protection for public health. A total of 18 water samples were measured with an electrostatic collection type radon monitor (RAD7, Durridge Co., USA). The concentration of radon in natural hot spring water samples in the West Java region, Indonesia ranges from 0.26 to 31 Bq L−1. An estimate of the annual effective dose in the natural hot spring water area ranges from 0.51 to 0.71 mSv with a mean of 0.60 mSv for workers. Meanwhile, the annual effective dose for the public ranges from 0.10 to 0.14 mSv with an average of 0.12 mSv. This value is within the range of the average committed effective dose from inhalation and terrestrial radiation for the general public, 1.7 mSv annually.
Air exchange through a porous medium depends partly on a pressure gradient induced in it, i.e., air-flow conditions of the outer air. Consequently, response of diffusion-type detectors to radon and thoron may vary with air-flow conditions surrounding the detectors. This effect may be significant for thoron measurement because thoron has a shorter half-life than radon. The present study examined response of diffusion-type detectors (RADUETs and one AlphaGUARD) to thoron with respect to wind speed using a thoron calibration chamber. Response of RADUETs to thoron increased with wind speed. Response of the AlphaGUARD increased with wind speed, but it became constant at a high wind speed. Different response trends to thoron between the RADUETs and the AlphaGUARD could be qualitatively explained by flow states induced by the pressure gradient in the filter or the sponge of these detectors. For RADUETs, laminar (Darcy) flow was induced in the sponge in the examined wind speed range, which meant that thoron entry into the detector increased with wind speed. For the AlphaGUARD, laminar flow was induced in the filter in the low wind speed range, whereas flow was changed to turbulent (non-Darcy) flow at a high wind speed for which thoron entry into the detector did not depend on wind speed.
Ten years have elapsed since the accident at the Fukushima Daiichi Nuclear Power Plant in 2011, and the relative contribution of natural radiation is increasing in Fukushima Prefecture due to the reduced dose of artificial radiation. In order to accurately determine the effective dose of exposure to artificial radiation, it is necessary to evaluate the effective dose of natural as well as artificial components. In this study, we measured the gamma-ray pulse-height distribution over the accessible area of Namie Town, Fukushima Prefecture, and evaluated the annual effective dose of external exposure by distinguishing between natural and artificial radionuclides. The estimated median (range) of absorbed dose rates in air from artificial radionuclides as of 1 April 2020, is 133 (67–511) nGy h−1 in the evacuation order cancellation zone, and 1306 (892–2081) nGy h−1 in the difficult-to-return zone. The median annual effective doses of external exposures from natural and artificial radionuclides were found to be 0.19 and 0.40 mSv in the evacuation order cancellation zone, and 0.25 and 3.9 mSv in the difficult-to-return zone. The latest annual effective dose of external exposure discriminated into natural and artificial radionuclides is expected to be utilized for radiation risk communication.
Recently, some commercially available active-type radon–thoron monitors were developed; however, their performance has not been characterized. This article presents the characteristics of three commercially available active-type radon–thoron monitors (RAD7, Radon Mapper, and AlphaGUARD) at different sampling flow rates. The thoron concentration measured by the monitors was compared with the reference value measured by a grab sampling method. As a result, the ratio of the measured concentration to the reference increased with flow rate for the RAD7 and the Radon Mapper although that of the AlphaGUARD decreased. The difference may be attributed to the coefficients used in the calculation and the measurement time scheme. The results indicate the importance of the sampling flow rate in thoron measurement. Monitoring of flow rate at the measurement and periodic calibration at multiple sampling flow rates should be conducted for quality assurance and quality control of the measurand.