Devon Richtsmeier

Devon Richtsmeier


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
DRDevon Richtsmeier
Devon Richtsmeier
EGE. Guliyev
E. Guliyev
KIK. Iniewski
K. Iniewski
MBM. Bazalova-Carter
M. Bazalova-Carter

10 February 2023 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
JLJosie Laidlaw
Josie Laidlaw
NENicolas Earl
Nicolas Earl
NSNihal Shavdia
Nihal Shavdia
RDRayna Davis
Rayna Davis
SMSarah Mayer
Sarah Mayer
MBMagdalena Bazalova-Carter
Magdalena Bazalova-Carter
The goal of this work was to build an anthropomorphic thorax phantom capable of breathing motion with materials mimicking human tissues in x-ray imaging applications. The thorax phantom, named Casper, was composed of resin (body), foam (lungs), glow polyactic acid (bones) and natural polyactic acid (tumours placed in the lungs). X-ray attenuation properties of all materials prior to manufacturing were evaluated by means of photon-counting computed tomography (CT) imaging on a table-top system. Breathing motion was achieved by a scotch-yoke mechanism with diaphragm motion frequencies of 10−20 rpm and displacements of 1 to 2 cm. Casper was manufactured by means of 3D printing of moulds and ribs and assembled in a complex process. The final phantom was then scanned using a clinical CT scanner to evaluate material CT numbers and the extent of tumour motion. Casper CT numbers were close to human CT numbers for soft tissue (46 HU), ribs (125 HU), lungs (−840 HU) and tumours (−45 HU). For a 2 cm diaphragm displacement the largest tumour displacement was 0.7 cm. The five tumour volumes were accurately assessed in the static CT images with a mean absolute error of 4.3%. Tumour sizes were either underestimated for smaller tumours or overestimated for larger tumours in dynamic CT images due to motion blurring with a mean absolute difference from true volumes of 10.3%. More Casper information including a motion movie and manufacturing data can be downloaded from http://web.uvic.ca/~bazalova/Casper/.

19 February 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
DRDevon Richtsmeier
Devon Richtsmeier
PRPierre-Antoine Rodesch
Pierre-Antoine Rodesch
KIKris Iniewski
Kris Iniewski
MBMagdalena Bazalova-Carter
Magdalena Bazalova-Carter
Objective. Computed tomography (CT) has advanced since its inception, with breakthroughs such as dual-energy CT (DECT), which extracts additional information by acquiring two sets of data at different energies. As high-flux photon-counting detectors (PCDs) become available, PCD-CT is also becoming a reality. PCD-CT can acquire multi-energy data sets in a single scan by spectrally binning the incident x-ray beam. With this, K-edge imaging becomes possible, allowing high atomic number (high-Z) contrast materials to be distinguished and quantified. In this study, we demonstrated that DECT methods can be converted to PCD-CT systems by extending the method of Bourque et al (2014). We optimized the energy bins of the PCD for this purpose and expanded the capabilities by employing K-edge subtraction imaging to separate a high-atomic number contrast material. Approach. The method decomposes materials into their effective atomic number ( Z eff ) and electron density relative to water ( ρ e ). The model was calibrated and evaluated using tissue-equivalent materials from the RMI Gammex electron density phantom with known ρ e values and elemental compositions. Theoretical Z eff values were found for the appropriate energy ranges using the elemental composition of the materials. Z eff varied slightly with energy but was considered a systematic error. An ex vivo bovine tissue sample was decomposed to evaluate the model further and was injected with gold chloride to demonstrate the separation of a K-edge contrast agent. Main results. The mean root mean squared percent errors on the extracted Z eff and ρ e for PCD-CT were 0.76% and 0.72%, respectively and 1.77% and 1.98% for DECT. The tissue types in the ex vivo bovine tissue sample were also correctly identified after decomposition. Additionally, gold chloride was separated from the ex vivo tissue sample with K-edge imaging. Significance. PCD-CT offers the ability to employ DECT material decomposition methods, along with providing additional capabilities such as K-edge imaging.

20 June 2023 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
DRDevon Richtsmeier
Devon Richtsmeier
PRPierre-Antoine Rodesch
Pierre-Antoine Rodesch
KIKris Iniewski
Kris Iniewski
WSWilliam Siu
William Siu
MBMagdalena Bazalova-Carter
Magdalena Bazalova-Carter
CT stent imaging suffers from blooming and metal artifacts, reducing the diagnostic quality of images in the areas around stents. Photon-counting detectors (PCDs) have been shown to reduce these artifacts. Two clinical scanners, a GE Optima 580 and Discovery IQ, were compared to a bench-top PCD-CT system for stent imaging with three stents: Medtronic Protégé, Cordis Precise, and Cordis S.M.A.R.T. Control. The apparent strut thickness, lumen diameter, and lumen attenuation of the stents were evaluated in reconstructed images. K-edge images were also reconstructed to demonstrate more accurate delineation of the tantalum radiopaque markers. PCD-CT offered lower percent differences for strut thickness for all three stents (p < 0.001) and for lumen diameter for the Protégé and Precise stents (p < 0.01). The lumen attenuation was more accurate with PCD-CT as well (p < 0.01), excluding the comparisons between the Optima 580 and PCD-CT for the Protégé and Precise stents. The PCD-CT system was better able to delineate stents, specifically strut thickness. The stents were more easily distinguished in PCD-CT images and in 3D volume renderings than the clinical systems. The tantalum radiopaque markers were clearly visible in K-edge images due to reduced metal artifacts.

20 September 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
XDXinchen Deng
Xinchen Deng
DRDevon Richtsmeier
Devon Richtsmeier
PRPierre-Antoine Rodesch
Pierre-Antoine Rodesch
KIKris Iniewski
Kris Iniewski
MBMagdalena Bazalova-Carter
Magdalena Bazalova-Carter
Objective. The objective of this study is to explore the capabilities of photon-counting computed tomography (PCCT) in simultaneously imaging and differentiating materials with close atomic numbers, specifically barium (Z = 56) and iodine (Z = 53), which is challenging for conventional computed tomography (CT). Approach. Experiments were conducted using a bench-top PCCT system equipped with a cadmium zinc telluride detector. Various phantom setups and contrast agent concentrations (1%–5%) were employed, along with a biological sample. Energy thresholds were tuned to the K-edge absorption energies of barium (37.4 keV) and iodine (33.2 keV) to capture multi-energy CT images. K-edge decomposition was performed using K-edge subtraction and principal component analysis (PCA) techniques to differentiate and quantify the contrast agents. Main results. The PCCT system successfully differentiated and accurately quantified barium and iodine in both phantom combinations and a biological sample, achieving high correlations ( R 2 ≈ 1 ) between true and reconstructed concentrations. PCA outperformed K-edge subtraction, particularly in the presence of calcium, by providing superior differentiation between barium and iodine. Significance. This study demonstrates the potential of PCCT for reliable, detailed imaging in both clinical and research settings, particularly for contrast agents with similar atomic numbers. The results suggest that PCCT could offer significant improvements in imaging quality over conventional CT, especially in applications requiring precise material differentiation.

22 May 2020 in Toxins
Verified
Journal Article
Open access
PDF file
NSNisha Shrestha
Nisha Shrestha
CTChristopher Thomas
Christopher Thomas
DRDevon Richtsmeier
Devon Richtsmeier
ABAndrew Bogard
Andrew Bogard
RHRebecca Hermann
Rebecca Hermann
Daniel FologeaDaniel Fologea
Daniel Fologea
Pore-forming toxins are alluring tools for delivering biologically-active, impermeable cargoes to intracellular environments by introducing large conductance pathways into cell membranes. However, the lack of regulation often leads to the dissipation of electrical and chemical gradients, which might significantly affect the viability of cells under scrutiny. To mitigate these problems, we explored the use of lysenin channels to reversibly control the barrier function of natural and artificial lipid membrane systems by controlling the lysenin’s transport properties. We employed artificial membranes and electrophysiology measurements in order to identify the influence of labels and media on the lysenin channel’s conductance. Two cell culture models: Jurkat cells in suspension and adherent ATDC5 cells were utilized to demonstrate that lysenin channels may provide temporary cytosol access to membrane non-permeant propidium iodide and phalloidin. Permeability and cell viability were assessed by fluorescence spectroscopy and microscopy. Membrane resealing by chitosan or specific media addition proved to be an effective way of maintaining cellular viability. In addition, we loaded non-permeant dyes into liposomes via lysenin channels by controlling their conducting state with multivalent metal cations. The improved control over membrane permeability might prove fruitful for a large variety of biological or biomedical applications that require only temporary, non-destructive access to the inner environment enclosed by natural and artificial membranes.