Željka Antić

Dr. Željka Antić

Vinča Institute of Nuclear Sciences, National Institute of the Republic of Serbia, University of Belgrade, Belgrade, Serbia
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2012 in Materials Chemistry and Physics
Verified
Journal Article
Closed access
Željka AntićŽeljka Antić
Željka Antić
Radenka Krsmanovic WhiffenRadenka Krsmanovic Whiffen
Radenka Krsmanovic Whiffen
MNMarko G Nikolic
Marko G Nikolic
Milena Marinović-CincovićMilena Marinović-Cincović
Milena Marinović-Cincović
MMMiodrag Mitrić
Miodrag Mitrić
Miroslav DramićaninMiroslav Dramićanin
Miroslav Dramićanin

1 October 2014 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
MNMarko G Nikolic
Marko G Nikolic
Željka AntićŽeljka Antić
Željka Antić
SĆSanja Ćulubrk
Sanja Ćulubrk
Jovan M. NedeljkovićJovan M. Nedeljković
Jovan M. Nedeljković
Miroslav DramićaninMiroslav Dramićanin
Miroslav Dramićanin

18 March 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
MSMarkus Suta
Markus Suta
Željka AntićŽeljka Antić
Željka Antić
VĐVesna Đorđević
Vesna Đorđević
SKSanja Kuzman
Sanja Kuzman
Miroslav DramićaninMiroslav Dramićanin
Miroslav Dramićanin
AMAndries Meijerink
Andries Meijerink
Ratiometric luminescence thermometry employing luminescence within the biological transparency windows provides high potential for biothermal imaging. Nd3+ is a promising candidate for that purpose due to its intense radiative transitions within biological windows (BWs) I and II and the simultaneous efficient excitability within BW I. This makes Nd3+ almost unique among all lanthanides. Typically, emission from the two 4F3/2 crystal field levels is used for thermometry but the small ~100 cm−1 energy separation limits the sensitivity. A higher sensitivity for physiological temperatures is possible using the luminescence intensity ratio (LIR) of the emissive transitions from the 4F5/2 and 4F3/2 excited spin-orbit levels. Herein, we demonstrate and discuss various pitfalls that can occur in Boltzmann thermometry if this particular LIR is used for physiological temperature sensing. Both microcrystalline, dilute (0.1%) Nd3+-doped LaPO4 and LaPO4: x% Nd3+ (x = 2, 5, 10, 25, 100) nanocrystals serve as an illustrative example. Besides structural and optical characterization of those luminescent thermometers, the impact and consequences of the Nd3+ concentration on their luminescence and performance as Boltzmann-based thermometers are analyzed. For low Nd3+ concentrations, Boltzmann equilibrium starts just around 300 K. At higher Nd3+ concentrations, cross-relaxation processes enhance the decay rates of the 4F3/2 and 4F5/2 levels making the decay faster than the equilibration rates between the levels. It is shown that the onset of the useful temperature sensing range shifts to higher temperatures, even above ~ 450 K for Nd concentrations over 5%. A microscopic explanation for pitfalls in Boltzmann thermometry with Nd3+ is finally given and guidelines for the usability of this lanthanide ion in the field of physiological temperature sensing are elaborated. Insight in competition between thermal coupling through non-radiative transitions and population decay through cross-relaxation of the 4F5/2 and 4F3/2 spin-orbit levels of Nd3+ makes it possible to tailor the thermometric performance of Nd3+ to enable physiological temperature sensing.



30 September 2013 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
VLVesna Lojpur
Vesna Lojpur
MNMarko G Nikolic
Marko G Nikolic
DJD. Jovanović
D. Jovanović
MMMina Medić
Mina Medić
Željka AntićŽeljka Antić
Željka Antić
Miroslav DramićaninMiroslav Dramićanin
Miroslav Dramićanin
Herein, temperature dependencies of emission and emission decay of Zn2SiO4:Mn2+ powder in the range from room temperature to 300 °C is reported. These dependencies allow temperature sensing from luminescence measurements, since Mn2+ emission intensity, emission band spectral position, and emission decay are rapidly changing over the entire temperature range. For fluorescence intensity ratio method, measurement that relays on emission intensity changes with temperature, sensitivity of 12.2% is found. In the case of lifetime thermometry, method that relays on emission decay changes with temperature, sensitivity of 0.48% is determined. Both sensitivity values are among the highest ever recorded for inorganic materials.