Zhiwen Yuan

Zhiwen Yuan


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2020 in IEEE Magnetics Letters
Verified
Journal Article
Closed access
Huan LiuHuan Liu
Huan Liu
XWXiaobin Wang
Xiaobin Wang
HWHongpeng Wang
Hongpeng Wang
JBJunchi Bin
Junchi Bin
HDHaobin Dong
Haobin Dong
XLXinqun Luan
Xinqun Luan
A miniature magnetic gradient tensor system is presented in this study, which could serve as a ready-to-use device for small spacecraft using in mineral prospection, unexploded explosive ordnance exploration, etc. The system consists of a magneto-inductive (MI) sensors array, a signal extraction circuit, and a micro-controller. A magnetic gradient full-tensor configuration utilizes four MI sensors arranged on a planar cross structure, was employed to further suppress the influence of the orientation and Orthogonal errors. The performance of the system is validated by checking data validation and magnetic anomaly detection. Numerous experimental results demonstrate that the system is able to detect a low-amplitude magnetic field as low as 8.28 nT at 10 Hz, with a typical noise floor of ${0.235 nT/Hz^{1/2}}$ at 1 Hz. Further, this system can configure the nearby ferromagnetic object clearly and shows the potential for identifying multiple objects, which indicates its feasibility for weak magnetic anomaly detection.

2 March 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JGJian Ge
Jian Ge
RWRui Wang
Rui Wang
HDHaobin Dong
Haobin Dong
Huan LiuHuan Liu
Huan Liu
QZQianwei Zheng
Qianwei Zheng
HZHaiyang Zhang
Haiyang Zhang
The diversity of magnetic field information obtained in marine geomagnetic measurements is of great relevance to defining detailed features of the targets. In this article, a solution algorithm based on the combination of scalar and vector fields is proposed. The magnetic direction of the geomagnetic field was obtained by repeatedly applying bias fields, and the multiparameter integrated measurement is realized based on the geometric relationship of the geomagnetic parameters. To make an instrument feasible for undersea measurement, a miniaturized multiparameter magnetometer was constructed within the limited space of a pressure tank, using an Overhauser scalar sensor and a spherical coil for generating bias fields. Test platforms were built to evaluate the scalar sensor and spherical coil. Results from a nonmagnetic laboratory showed that the expanded uncertainty of the scalar sensor was 0.11 nT, whereas the magnetic field generated by the spherical coil had 97% uniformity and completely engulfed the scalar sensor. Moreover, field experiments indicated that the standard deviation of prototype instrument in magnetic direction (3 $^{\prime \prime }$ ) was close to that of declination–inclination magnetometer, whereas its standard deviation in Z -component of 0.24 nT was better than that of a commercial fluxgate magnetometer. It also had markedly better measurement stability, with no temperature drift.

29 December 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WLWang Luo
Wang Luo
JGJian Ge
Jian Ge
Huan LiuHuan Liu
Huan Liu
GWGuanzhong Wang
Guanzhong Wang
BBBing Jie Bai
Bing Jie Bai
HDHaobin Dong
Haobin Dong
Earth magnetic field sensors are used to detect the geomagnetic field and are critical for research in the geosciences and in prospecting for mineral resources. Today, the Overhauser sensor is the most accurate scalar sensor among widely applied geomagnetic field sensors. However, the Overhauser sensor shows severe orientation sensitivity due to its solenoid induction coil. Hence, in mobile applications that use Overhauser sensors, the accuracy of geomagnetic field data is decreased because of this orientation sensitivity. This paper proposes a method of suppressing the orientation sensitivity of the Overhauser sensor from the perspectives of the sensor structure, signal conditioning circuit, and measurement algorithm. To address the problem of no signal output from the sensor in a certain orientation, the parameters of the solenoid coil are optimized. Moreover, we designed a frequency adaptive high-accuracy signal extraction method based on a closed-loop feedback strategy, to decrease the measurement error contributed by the signal conditioning circuit and frequency measurement algorithm. Finally, we implement a prototype device using the proposed method with the commercial instruments to characterize the performance of our prototype, and test the orientation sensitivity of the prototype in the standard magnetic metering station. Experimental results demonstrate that the proposed sensor can achieve high-accuracy measurement capabilities comparable to those of commercial instruments in any orientation, indicating that its orientation sensitivity is efficiently suppressed.

1 October 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JGJian Ge
Jian Ge
XZXinglin Zhang
Xinglin Zhang
HDHaobin Dong
Haobin Dong
Huan LiuHuan Liu
Huan Liu
WWWenjie Wang
Wenjie Wang
JZJun Zhu
Jun Zhu
In aeromagnetic surveys, poor aircraft heading and weather may frequently cause a classical optically-pumped sensor to enter into or close to its dead zone, which results in unavoidable outliers that seriously reduce aeromagnetic compensation. To address these problems, a method to identify rapidly and pre-cull magnetic outliers based on the gray system theory is proposed to reduce their negative influence during the estimation of coefficients and target detection robustness. By constructing a gray region of aeromagnetic data and then checking whether the data at the end points of the region are normal, aeromagnetic outliers can be culled. The simulation results show that even if the outlier rate is increased to 20%, the average of the correct culling rate of the proposed method can still reach 99.67%, at which the culling effect is highly robust. We constructed an experimental survey platform and conducted a flight test. The results show that the improvement ratio of the proposed method can reach 4.36, which is 10.38 times higher than the conventional method.

1 August 2020 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
LSLuo Sha
Luo Sha
ZYZhiwen Yuan
Zhiwen Yuan
XKXu Kan
Xu Kan
JZJinli Zhang
Jinli Zhang
DHDeng Honggang
Deng Honggang
In recent years, abnormal behavior detection has become an active research field in computer vision and image processing. Several methods based on traditional two-stream CNN or 3D-CNN have been proposed and successfully applied in abnormal behavior detection. However, the abnormal behavior data is rarely less in the real scenario, in other words, the data is imbalanced, which may lead to overfitting problem and affect the final results. In this paper, an improved abnormal behavior detection method based on a two-stream CNN method was proposed to address the problem mentioned above. In the proposed method, DenseNet is adopted to extract both spatial and temporal features, and focal loss is employed to alleviate the influence of imbalanced data. The experiment results show that the proposed method provides a good performance in the real-world scenario.

3 November 2020 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
JGJian Ge
Jian Ge
ZHZhifan Huo
Zhifan Huo
HDHaobin Dong
Haobin Dong
Huan LiuHuan Liu
Huan Liu
JQJunli Qian
Junli Qian
JZJun Zhu
Jun Zhu
The initial orientation error of a coil vector magnetometer directly determines the measurement accuracy of the magnetic field direction. The traditional initial orientation method requires auxiliary manually operated instruments. To solve this problem, we propose an electrical orientation method based on applying bias fields. To analyze quantitatively the orientation error of the proposed method, a physical model for the coil orientation indicator and measurement errors of the magnetic direction was developed that exploits measurements of the deflected field obtained after applying two oppositely directed bias fields. The simulation results show that, when the difference indicator is 0.7 nT, the measurement error of the magnetic direction is less than 9°. Moreover, when the bias field strength is greater than 30% of the geomagnetic field strength during the orientation operation, the influence of the change in strength of the bias field on the measurement error of the magnetic direction diminishes significantly. The indirect effect of the measurement error of the total-field sensor on the measurement accuracy of the magnetic direction was also analyzed. To verify this method, we designed an experimental setup and conducted a comparative experiment. The results show that as the difference indicator increases, the measurement error of the magnetic direction increases accordingly. When this indicator is adjusted to about0.7 nT, the measurement error of the magnetic direction is less than 11.16'', which is in agreement with theoretical results.