Qianwei Zheng

Qianwei Zheng

Auto-generated profile, based on publicly available information

Qianwei Zheng

School of Automation, China University of Geosciences, Wuhan, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JGJian Ge
Jian Ge
RWRui Wang
Rui Wang
HDHaobin Dong
Haobin Dong
Huan LiuHuan Liu
Huan Liu
QZQianwei Zheng
Qianwei Zheng
HZHaiyang Zhang
Haiyang Zhang
The diversity of magnetic field information obtained in marine geomagnetic measurements is of great relevance to defining detailed features of the targets. In this article, a solution algorithm based on the combination of scalar and vector fields is proposed. The magnetic direction of the geomagnetic field was obtained by repeatedly applying bias fields, and the multiparameter integrated measurement is realized based on the geometric relationship of the geomagnetic parameters. To make an instrument feasible for undersea measurement, a miniaturized multiparameter magnetometer was constructed within the limited space of a pressure tank, using an Overhauser scalar sensor and a spherical coil for generating bias fields. Test platforms were built to evaluate the scalar sensor and spherical coil. Results from a nonmagnetic laboratory showed that the expanded uncertainty of the scalar sensor was 0.11 nT, whereas the magnetic field generated by the spherical coil had 97% uniformity and completely engulfed the scalar sensor. Moreover, field experiments indicated that the standard deviation of prototype instrument in magnetic direction (3 $^{\prime \prime }$ ) was close to that of declination–inclination magnetometer, whereas its standard deviation in Z -component of 0.24 nT was better than that of a commercial fluxgate magnetometer. It also had markedly better measurement stability, with no temperature drift.

3 November 2020 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
JGJian Ge
Jian Ge
ZHZhifan Huo
Zhifan Huo
HDHaobin Dong
Haobin Dong
Huan LiuHuan Liu
Huan Liu
JQJunli Qian
Junli Qian
JZJun Zhu
Jun Zhu
The initial orientation error of a coil vector magnetometer directly determines the measurement accuracy of the magnetic field direction. The traditional initial orientation method requires auxiliary manually operated instruments. To solve this problem, we propose an electrical orientation method based on applying bias fields. To analyze quantitatively the orientation error of the proposed method, a physical model for the coil orientation indicator and measurement errors of the magnetic direction was developed that exploits measurements of the deflected field obtained after applying two oppositely directed bias fields. The simulation results show that, when the difference indicator is 0.7 nT, the measurement error of the magnetic direction is less than 9°. Moreover, when the bias field strength is greater than 30% of the geomagnetic field strength during the orientation operation, the influence of the change in strength of the bias field on the measurement error of the magnetic direction diminishes significantly. The indirect effect of the measurement error of the total-field sensor on the measurement accuracy of the magnetic direction was also analyzed. To verify this method, we designed an experimental setup and conducted a comparative experiment. The results show that as the difference indicator increases, the measurement error of the magnetic direction increases accordingly. When this indicator is adjusted to about0.7 nT, the measurement error of the magnetic direction is less than 11.16'', which is in agreement with theoretical results.

21 July 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JGJian Ge
Jian Ge
JQJunli Qian
Junli Qian
WWWudi Wen
Wudi Wen
HDHaobin Dong
Haobin Dong
QZQianwei Zheng
Qianwei Zheng
ZYZhiwen Yuan
Zhiwen Yuan
In long-term observations, the attitude drift of a coil vector magnetometer caused by mechanical deformation will directly affect the accuracy of magnetic direction measurements. To solve this problem, we propose a characterization model and calibration method for the measurement error associated with attitude drift. The proposed model uses an attitude matrix to define a mapping from the unmeasurable characteristic angle to the measurable magnetometer attitude. We propose a new $\textit {dif}$ coordinate system to establish a characterization model linking the characteristic angle of the magnetometer attitude to the measurement error of the magnetic direction, thereby permitting quantitative analysis of the attitude drift and real-time suppression of its negative influence on the measurement accuracy without complex manual operations. The proposed model shows that in the presence of small attitude changes, the measurement error of the magnetic inclination is mainly determined by the south–north nonlevelness of magnetometer, and the error of magnetic declination is mainly determined by the magnetometer orientation and east–west nonlevelness. Our simulations show that when the east–west nonlevelness, south–north nonlevelness, and orientation angle of the magnetometer are ${232.6''}$ , ${206.2'' }$ , and ${615.4''}$ , respectively, the measurement errors (baseline shift) of the magnetic inclination and declination are ${206.9''}$ and ${364.2''}$ , respectively. To verify the results, we designed an experimental platform and conducted a comparative experiment. The results show that in the presence of the aforementioned attitude parameters, the measurement errors of the magnetic inclination and declination can be reduced by 97.8% and 88.6%, respectively, through error calculation and baseline correction.